What was found
DURING INSPECTION, FOUND CORROSION OUT OF LIMITS ON THE FLIGHT DECK FLOORBEAM AT BS 217, BL 0 - RBL 18, REPAIRED IAW SRM 53-10-51, REPAIR 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION OUT OF LIMITS ON THE FLIGHT DECK FLOORBEAM AT BS 217, BL 0 - RBL 18, REPAIRED IAW SRM 53-10-51, REPAIR 2.