JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA2016062115054Angle · corrodedFLOORBEAM ANGLE AT BS 280 HAS CORROSION. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01. PARAGRAPH 5.E AND FOUND OUT OF LIMITS. REMOVED AND REPLACED THE FLOORBEAM ANGLE IAW SRM 51-42-06-001-001-A01.SDR AALA20160621003Floorbeam · wornAIRCRAFT WAS IN BASE MAINTENANCE. CABIN FLOORBEAM AT FUSELAGE STA 325 IS WORN AROUND FLOOR PANEL HOLES BETWEEN LBL 48 AND LBL 27. REPAIRED FLOORBEAM IAW SRM 53-00-51-2R-1.SDR YENA20160621579Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM LOCATION: -Y1162, LOCATION FRAME 67 + 18" AT AFT GALLEY AREA; R & R FLOORBEAM -Y1162, FR 67 +18" AT AFT GALLEY AREA.SDR YENA20160621578Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM LOCATION: -Y1162, FR 67 +15" AT AFT GALLEY AREA. R & R FLOORBEAM -Y1162, FRAME 67 + 15" AT AFT GALLEY AREA.SDR YENA20160621577Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM LOCATION: -Y1292 BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA. R & R
FLOORBEAM AT FWD GALLEY AREA.SDR YENA20160621576Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM, +Y1292 BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y1292 BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA.SDR YENA20160621575Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM, -Y765 BETWEEN FRAME 20 TO FRAME 24 AT FWD GALLEY AREA. R & R FLOORBEAM -Y765 BETWEEN FRAME 20 TO FRAME 24 AT FWD GALLEY AREA.SDR YENA20160621574Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM, LOCATION: -Y254, FRAME 20 AT FWD GALLEY AREA; R & R FLOORBEAM -Y254, FRAME 20 AT FWD GALLEY AREA.SDR YENA20160621573Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOORBEAM, LOCATION: +Y1162, FRAME 67+18" AT AFT GALLEY AREA. R & R FLOORBEAM Y1162 FRAME 67 + 18" AT AFT GALLEY AREA IAW SRM 51-72-11.SDR CALA2016062295473Floorbeam · corrodedMAIN CABIN FLOORBEAM UPPER CHORD CORRODED AT BS 1640 BETWEEN BL0 AND RBL 24.75. REMOVED CORROSION AND FOUND BLEND OUT EXCEED SRM LIMITS. REMOVED EXISTING REPAIR, FABRICATED AND INSTALLED NEW UPPER CHORD SPLICE. REPAIR CHORD FROM RBL63-LBL 24.75 REF ECRA 531SDR AALA20160620016Floorbeam · damagedAIRCRAFT WAS IN BASE MAINTENANCE. FLOORBEAM AT FUSELAGE STATION 764 HAS 4 ELONGATED HOLES AT APPROXIMATELY RBL 30. REPAIRED FLOORBEAM BETWEEN RBL 18 AND RBL 44 IAW SRM 53-00-51-2R-1.SDR SWAA2016072254098Floorbeam · corrodedAFT FLOORBEAM CORRODED AT BS 986.5, RBL 42. REPAIRED FLOORBEAM IAW EA.SDR SWAA2016071954027Floorbeam · corrodedAFT FLOORBEAM UPPER SURFACE CORRODED AT BS 986.5, LBL 46. REPAIRED THE FLOORBEAM IAW EA AND ER.SDR REXA2016061901215Floorbeam · crackedMAIN CABIN FLOORBEAM HAS A CRACKED ANGLE AT BS 280 LBL 9. REMOVED & REPLACED THE ANGLE IAW SRM 51-42-21.SDR SWAA2016071553826Floorbeam · crackedFLOORBEAM CRACKED AT BS 294.5, RBL 52. REPAIRED CHORD IAW EA.SDR DALA2016062004847Floorbeam · corrodedLEFT FLOORBEAM Y765 HAS 2 SPOTS OF CORROSION. REMOVED CORROSION IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS. R & R FLOORBEAM.SDR UIEA2016062000448Floorbeam · corrodedFOUND CORROSION AT UPPER CAP OF MAIN DECK FLOORBEAM AT STA 2260, LBL 23. REPAIRED CORROSION AT UPPER CAP OF MAIN DECK FLOORBEAM AT STA 2260, LBL 23 IAW EI T2016A53M-1373, REV 1. CONDITION CHECK NORMAL AND JOB COMPLETED.SDR UIEA2016062000450Floorbeam · corrodedFOUND BEAM M/D, FLOORBEAM UPPER CAP HAD CORROSION AT STA 2160, LBL 2. EI T2016A53M-1372, REV 1. JOB COMPLETED AND CONDITION CHECK NORMAL.SDR REXA2016061701213Floorbeam · corrodedFLOORBEAM CORRODED AT BS 559+80, RBL 27. REPAIRED FLOORBEAM IAW SRM 53-00-43 FIG 203.SDR SWAA2016070553523Floorbeam · corrodedAFT CARGO BAY FLOORBEAM TEE STRAP CORRODED AT BS 887, BETWEEN LBL 22 TO RBL 22. R & R THE FLOORBEAM TEE SPLICE IAW SRM.SDR SWAA2016070553522Strap · corrodedAFT CARGO BAY FLOORBEAM SPLICE TEE STRAP CORRODED AT BS 772, BETWEEN LBL 23 TO RBL 23. R & R FLOORBEAM STRAP IAW SRM.SDR SWAA2016070553521Floorbeam · corrodedAFT CARGO BAY FLOORBEAM SPLICE TEE STRAP CORRODED AT BS 727D+5, BETWEEN LBL 20 TO RBL 20. R & R FLOORBEAM TEE SPLICE IAW SRM.SDR REXA2016061701144Floorbeam · crackedCOCKPIT FLOORBEAMS AT LBL 12 AND RBL 12 ARE CRACKED. CONTINUATION CARD 81513716, OP 22. REPAIRED LT & RT COCKPIT FLOORBEAM AT LBL 12 AND RBL 12 IAW EO R53191. OPS TEST OF THE LANDING GEAR EXTENSION AND RETRACTION GOOD IAW AMM 32-30-00-710-801-A01.SDR REXA2016061601222Floorbeam · crackedMAIN CABIN FLOOR STRUCTURE HAS A CRACKED ANGLE AT BS 280 RBL 9. REMOVED & REPLACED ANGLE IAW SRM 51-42-21.SDR A6WA201644007Floorbeam · corrodedAFT FLOORBEAM FITTING AT LBL27 AND FS610.00 TO 621.00 HAS CORROSION ON FLANGE AND UNDER TEFLON CAP STRIP. REPAIRED CORROSION AT FS 610.00 TO 621.00, LBL27 CARGO FLOORBEAM REO 601R-53-61-4530, REV-A.SDR A6WA201644006Floorbeam · corrodedCARGO PIT FLOORBEAM, FLOOR SUPPORT FLANGE AT LBL27 IS CORRODED BETWEEN FS 559+112 TO FS 610.00. REPLACED CORRODED FLOORBEAM IAW SRM 51-40-11, 51-42-21, 51-42-06.SDR CALA2016061700367Floorbeam · corrodedCABIN BS1518, LBL 1 TO RBL 3 FLOORBEAM FOUND CORROSION. CABIN FLOORBEAM AT BS1518, LBL1 TO RBL 3 UPPER CHORD CORROSION REMOVED IAW SRM 51-10-02. BLENDED AREA D 0.065", ORIGINAL THICKNESS 0.090", WITHIN 2" X 8" LENGTH OUT OF SRM 53-00-51. ALLOWABLE DAMAGE 1,SDR DALA2016061604741Floorbeam · corrodedAT FR69, Y-1292 FLOORBEAM HAS CORROSION, FOUND TO BE OUT OF LIMITS, D=0.030", IAW TRIM 53-41-15, REPLACED WITH NEW STOCK, PN D5347218920400, IAW TRM 53-41-15.SDR COEA2016061414807Floorbeam · corrodedFLOORBEAM, FRAME 17 HAS CORROSION. REPAIRED IAW 0043023.SDR COEA2016061413807Floorbeam · corrodedFLOORBEAM 15 HAS CORROSION BETWEEN CENTER SEAT TRACKS. REPAIRED IAW SRM 530000-300-852-A01.SDR SWAA2016071153647Floorbeam · corrodedFORWARD WET AREA FLOORBEAM CORRODED AT BS 285, BETWEEN BL 0 TO LBL 7. REPAIRED THE FLOORBEAM IAW EA.SDR ASOA2016061415045Floorbeam · corrodedLBL 27 FLOORBEAM CORRODED BETWEEN 570-621. EVALUATED FLOORBEAM AT LBL27, FS 570-620, FOUND TO BE OUT OF LIMITS IAW SRM 53-61-43. R & R
FLOORBEAM AT FS 570-621, LBL27 IAW SRM 51-42-06 AND 51-42-21 LOCATED AND DRILLED NEW FLOORBEAM IAW SRM 51-40-41. COMPLIESDR SWIA201642289Floorbeam · corrodedFLOORBEAM AT RBL 9.0 HAS CORROSION ON ITS INBD FLANGE AROUND 2 RIVET HOLES AT APPROXIMATELY FS 810.00. REPAIRED FLOORBEAM AT RBL 9.0 AT FS 810.00 ON ITS INBD FLANGE AROUND 2 RIVET HOLES IAW REO AND SRM, PN: SH670-35823-3.SDR SCNA20160614080Floorbeam · corrodedAFT WET AREA FLOORBEAM BS 967, RBL 30 TO RBL 40 CORROSION AROUND 2 EA FLOORBOARD HOLES. AFT WET AREA FLOORBEAM BS 967, RBL 30 TO RBL 90 CORROSION AROUND 2 EA FLOOR BOARD HOLES. REMOVED DAMAGE DRILLED & FABRICATED TREATED PRIMED TOP COATED INSTALLED REPAIR.SDR DALA2016061404740Floorbeam · corrodedAT FRAME 70 FLOORBEAM, Y-765, HAS CORROSION AROUND FASTENER HOLE. REMOVED CORROSION AND WAS FOUND TO BE OUT OF LIMITS, REPLACED IAW TRM 53-41-15. D=0.050", PN D5347219320000, Y-765.SDR REXA2016061201173Floorbeam · corrodedFLOOR RAIL BEAM RBL9, FS 559.00+48 TO FS 559.00+80 HAS CORROSION ON THE OTBD FLANGE. R & R FLOORBEAM SECTION RBL9, FS 559.00+48 TO FS 559.00+68 IAW SRM 53-00-43. REPAIR NR 2 SM-27.SDR AALA20160612005Floorbeam · corrodedAIRCRAFT WAS IN BASE MAINTENANCE. CABIN FLOORBEAM AT FUSELAGE STA 347 IS CORRODED ON LOWER SURFACE OF TEE CAP BETWEEN LBL 28 AND LBL 47. REPAIRED FLOORBEAM IAW SRM 53-00-51-2R AND EA 261119.SDR SWAA2016062153080Floorbeam · crackedFLOORBEAM CHORD CRACKED AT BS 312, RBL 22, UPPER FLANGE. REPAIRED CHORD IAW SRM.SDR DALA2016061204644Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED BS 297 RBL 22-RBL 32. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM. FABRICATED LOCATED AND DRILLED NEW FLOORBEAM IAW DWG REV: B & CD INSTALLED NEW FLOORBEAM IAW SRM AND DWG REV: B.SDR ASAA2016060917074Support Strap · crackedFLOORBEAM SUPPORT STRAP IN ELECTRONIC EQUIPMENT BAY CRACKED AT FS 328 BL0. ACFT GROUNDED. R & R FLOORBEAM SUPPORT STRAP ON FS 328, BL0 IAW SRM 51-40-02-0E-0.SDR ASAA2016060917073Support Strap · crackedFLOORBEAM SUPPORT STRAP CRACKED IN ELECTRONICS EQUIPMENT BAY AT FS 328, RBL 33. ACFT GROUNDED. R & R FLOORBEAM SUPPORT STRAP ON FS 328, RBL 33 IAW SRM 51-40-02-0G-0.SDR DALA2016060904617Floorbeam · corrodedFLOORBEAM CORRODED, BS 200, LBL 4- RBL4. R & R SUPPORT IAW SRM 51-30-02.SDR DALA2016060904615Floorbeam · corrodedFLOORBEAM AT BS 200, RBL 44-54 CORRODED. R & R SUPPORT IAW DWG 9936534.SDR DALA2016060904614Floorbeam · corrodedFLOORBEAM CORRODED, BS 200, LBL 10-14. REPLACED SUPPORT IAW DWG 9936534.SDR FDEA201606081875Floorbeam · corrodedFORWARD CARGO COMPARTMENT BILGE SPACE, THERE ARE 2 AREAS OF CORROSION ALONG A LATERAL FLOORBEAM UPPER ANGLE UNDER 2 DIFFRENT ROLLER TRAYS AT AFT SIDE OF THE BS 879, FLOOR FRAME APPROXIMATE LBL 18 & LBL 30. FABRICATED ANGLE IAW DWG RAM1429.SDR ASOA2016060715018Floorbeam · corrodedFLOORBEAM AT LBL9, F/S 1015.00 TO F/S 1031.00 HAS CORROSION AROUND BOLT HEAD AND NON BEAM. COMPLIED WITH EC/TC REO 670-53-00-0029, REPAIRED FLOORBEAM AT FS 1015-FS 1031, LBL9 IAW EO 900-53-0023. REMOVED DAMAGED SECTION OF BEAM SECTION TRIMMED NEW SECTION OF SDR ASOA2016060715017Floorbeam · corrodedFLOORBEAM AT LBL 27, F/S 1015.00 TO 1031.00 HAS CORROSION AROUND BOLT HEAD AND NON BEAM. REPAIRED FLOORBEAM AT FS 1031, LBL 27, EECTC EO 900-53-0024 & REO 670-53-00-029.SDR IPXA2016061204516Floorbeam · damagedINSPECTION TYPE:5YR, MAIN CABIN FLOORBEAM AT FRAME 48 RT IS BENT AND BROKEN. REPLACED IAW SRM 51-40-21.SDR IPXA2016061204515Floorbeam · damagedINSPECTION TYPE:5YR, MAIN CABIN FLOORBEAM AT FRAME 51 BENT & BROKEN. REPLACED FLOORBEAM IAW SRM 51-40-21.SDR IPXA2016061204514Floorbeam · bentINSPECTION TYPE: 5YR, MAIN CABIN FLOORBEAM AT FRAME 50 RT IS BENT. REPLACED FLOORBEAM IAW SRM 51-40-21.