What was found
CABIN BS1518, LBL 1 TO RBL 3 FLOORBEAM FOUND CORROSION. CABIN FLOORBEAM AT BS1518, LBL1 TO RBL 3 UPPER CHORD CORROSION REMOVED IAW SRM 51-10-02. BLENDED AREA D 0.065", ORIGINAL THICKNESS 0.090", WITHIN 2" X 8" LENGTH OUT OF SRM 53-00-51. ALLOWABLE DAMAGE 1, FIG 101, LIMIT AND FLOORBEAM UPPER CHORD CORROSION. REMOVED AREA, REPAIRED IAW SRM 53-00-51, REPAIR 1, FIG 201 AND FORM 44.0008 ATTACHED ITEM 1-18.