JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA201201358Floorbeam · corrodedFLOORBEAM FS 280 FOUND CORRODED. REMOVE AND REPLACED ANGLE IAW SRM 51-42-06-001-001, 51-42-21-001-001, AND 51-421-22-001-001.SDR DALA1225951501Floorbeam · corrodedCARGO FLOORBEAM AT FS 1439 AT BL 0 - RBL 43 AND LBL 22 - LBL 36 LWR FLANGE IS CORRODED. WORKING FROM PRI.SDR DALA1225941501Floorbeam · corrodedCARGO FLOORBEAM AT FS 1461 BL 0 - LBL 29 AND RBL 7 - RBL 59 IS CORRODED. WORKING FROM PRI.SDR DALA1225931501Floorbeam · corrodedCARGO FLOORBEAM AT FS 1480 AT RBL 12 - RBL 59 AND LBL 2 - LBL 53 IS CORRODED. WORKING FROM PRI.SDR DALA1225921501Floorbeam · corrodedCARGO FLOORBEAM AT FS 1502 LBL 2 - LBL 53 AND RBL 8 - RBL 56 LWR FLANGE IS CORRODED. WORKING FROM PRI.SDR DALA1225911501Beam · corrodedCARGO FLOORBEAM AT FS 1417 BL-0 - RBL-22 LWR FLANGE IS CORRODED. WORKING FROM PRI.SDR DALA1225901501Floorbeam · corrodedCARGO FLOORBEAM AT FS 1480 BL-0 - LBL-14 IS CORRODED. WORKING FROM PRI.SDR DALA1226913121Floorbeam · corrodedAFT LAV/GALLEY BET FR68 TO FR69, Y-1292, FLOORBEAM HAS CORROSION. REMOVED CORROSION IAW A319 SRM 51-74-00. CHECKED LIMITS ORIG MAT THICKNESS=.150" L=1.5"W=.75" D=.030" OUT OF LIMITS IAW A319 SRM 53-00-14 PARA 4.B FIG 2. RECEIVED NEW FLOORBEAM. REMOVED FLOSDR DALA1226903121Floorbeam · corrodedAFT LAV/GALLEY BET FR66 TO FR68, Y-1292 FLOOR BEAM HAS CORROSION. REMOVED CORROSION IAW A319 SRM 51-74-00. CHECKED LIMITS ORIG MAT THICKNESS=.100" L=2.0"W=1.0" D=.025" OUT OF LIMITS IAW A319 SRM 53-00-14 PARA 4.B FIG 102. RECEIVED NEW FLOORBEAM. REMOVED FSDR DALA1226733121Floorbeam · corrodedAFT LAV/GALLEY BET FR68 TO FR69, Y+1292. FLOORBEAM HAS CORROSION. RETAIN FOR RECORDS. REMOVED CORROSION IAW A319 SRM 51-74-00 CHECKED LIMIT L=2" W=1.5" D=.053" ORIG MAT=.153" OUT OF LIMIT IAW A319 SRM 53-00-14 FIG 102. REMOVED DAMAGED FLOOR SUPPORT IAW A31SDR DALA1226723121Floorbeam · corrodedAFT LAV/GALLEY BET FR65 TO FR66, Y765 FLOORBEAM HAS CORROSION. BLENDED AREA IAW A319 SRM 51-74-00, DIMENSIONS OF REWORKED AREA ARE: L=1.03" W=.79" D=0.049" FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-00-14 FIG 102. REMOVED DAMAGED FLOORBEAM IAW A319 SRM 51-4SDR UHLA2012042200134Floorbeam · corrodedLEVEL 2 CORROSION ON COCKPIT FLOORBEAM FRM 11 DIRECTLY BEHIND CENTER CONSOLE. BLENDED CORROSION, FOUND TO BE OUT OF LIMITS, REPAIRED FRM 11 IAW EMB ETD 2012-00-5829.SDR DALA1226586818Floorbeam · corrodedCARGO FLOOR PANEL BEAM CORRODED AT NUT PLATES. CORROSION LOCATION: AFT CARGO STA 1340-1440 RBL 10 POS: AFT TASK REMOVED CARGO FLOOR PANEL BEGAN AT FACTORY SPLICE STA 1340-1440 DRILLED UP REPLACEMENT SECTION OF BEAM PER BAC DWG146N5390 ALODINED REPLACEMENT BEASDR DALA1226406818Floorbeam · corrodedFLOORBEAM - CORROSION LOCATION: BL 0 STA 1640. REMOVE CORROSION & FOUND OUT OF LIMITS PER B757 SRM 53-00-51. T-CAP REPLACED ON N/R 459.SDR CALA2012042300283Floorbeam · corrodedCABIN LT STA 303 LBL 30-45 FLOORBEAM UPPER SURFACE FOUND CORROSION. CABIN LT STA 303 LBL 5 TO LBL 58 FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AND HFEC NIL CRACK FOUND.SDR SWAA2012050903811Floorbeam · corrodedFLOORBEAM CORRODED AT BS 344, RBL 8. REMOVED AND REPLACED T-CAP PER SRM.SDR SWAA2012050903810Floorbeam · corrodedFLOORBEAM CORRODED AT BS 344, RBL 1. REMOVED AND REPLACED T-CAP PER SRM.SDR ASAA12511485Floorbeam · corrodedFORWARD CARGO PIT AFT FLOORBEAM CORRODED SEVERAL LOCATIONS. ACFT GROUNDED. R & R IAW SRM 51-40-05.SDR QXEA2012042000334Floorbeam · corrodedFLOORBEAM 728.102 CENTER SPLICE HAS MINOR CORROSION. REMOVED MINOR SURFACE CORROSION IAW SRM 51-21-00-00-02. CONFIRMED AREA CRACK FREE REF NTM 51-00-06-910-801. FOUND TO BE IN LIMITS IAW RD 8/4-53-4460. APPLIED ALODINED, PRIMER AND CPC IAW SRM 51-21-10-02-SDR SWIA201230505Floorbeam · cracked(C-CHECK) FS 280 FLOORBEAM CRACKED. REPAIRED FS 280 FLOORBEAM PER REO.SDR ASAA12511444Floorbeam · corrodedFWD CARGO PIT AFT FLOOR ATTACH ANGLE CORRODED, SERVERAL LOCATIONS. R & R IAW SRM 51-40-005.SDR AALA20120420004Floorbeam · corrodedCORROSION ON TOP OF LATERAL FLOORBEAM STATIONS 1660 TO 1662, LEFT BUTTLINE 59 TO 61, INBOARD OF LEFT NUMBER 4 DOOR. INSTALLED T-CAP AND REPAIR ANGLES PER EA B757-53-022922SDR CALA2012042000280Floorbeam · corrodedCABIN BS 303 LBL 21 TO 55 FLOORBEAM CORRODED. CABIN BS 303 LBL 6" TO LBL 64" FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR FIG 201 AND AFEC NIL CRACK FOUND ATTACH MAINTENANCE WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 26 ACCOMPLISHED.SDR CALA2012042000279Floorbeam · corrodedCABIN BS 325 LBL 21 TO 55 FLOORBEAM CORRODED. CABIN BS 325 LBL 15" TO LBL 63" FLOORBEAM UPPER CHORD REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AND AFEC NIL CRACK FOUND ATTACH MAINTENANCE WORK SHEET FORM 44.0008 ITEM 1 TO ITEM 30 ACCOMPLISHED.SDR SWAA2012051704100Floorbeam · corrodedFLOORBEAM UPPER CHORD CORRODED AT BS 986.5, LBL 43. REPAIRED CHORD IAW EO AND EA.SDR SWAA2012051103915Floorbeam · crackedFLOORBEAM CRACKED AT BS 947, LBL 54. REPAIRED BEAM PER SRM.SDR SWAA2012051103914Floorbeam · crackedLONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 668, LBL 24.8. REPAIRED CHORD PER SRM.SDR SWAA2012051103913Floorbeam · crackedLONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 661, LBL 24.8. REPAIRED CHORD PER SRM.SDR SWAA2012051103912Floorbeam · crackedLONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 664, LBL 24.8. REPAIRED CHORD PER EA.SDR SWAA2012051103911Floorbeam · crackedLONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 664, RBL 24.8. REPAIRED CHORD PER EA.SDR SWAA2012050903850Floorbeam · corrodedFLOORBEAM CORRODED AT BS 344, LBL 11. REPAIRED BEAM PER SRM.SDR DALA1229231501Floorbeam · corrodedMAIN DECK BS 1439 WL193 RBL 0 TO RBL 43 AND LBL 22 TO LBL 36, FLOORBEAM LWR FLANGE CORRODED. REPAIRED PER ERA 501559-14 REV ORIG.SDR DALA1229221501Floorbeam · corrodedM/DECK STA 1461 WL193 RBL7 TO RBL 59 AND LBL 0 TO LBL 29 FLOORBEAM LWR FLANGE CORRODED. REPAIRED PER ERA 501558-14 REV ORIG.SDR DALA1229201501Floorbeam · corrodedMAIN DECK BS 1480 WL193 RBL 12 TO RBL 59 AND LBL 2 TO LBL 53 LWR FLANGE FOUND CORRODED. REPAIRED PER ERA 501556-14 REV ORIG.SDR DALA1229191501Floorbeam · corrodedMAIN DECK BS 1502 FLOORBEAM LWR FLANGE CORRODED WL193 LBL 2 TO LBL 53 AND RBL 8 TO RBL 56 CORRODED. REPAIRED PER ERA 501557-14 REV ORIG.SDR DALA1229181501Floorbeam · corrodedMAIN DECK BS 1417 WL 193 RBL 0 TO RBL 22 FLOORBEAM LOWER FLANGE CORRODED. REPAIRED PER ERE 501555-14 REV ORIG.SDR R61A201204190246Floorbeam · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND FWD FUSE INBD FLOORBEAM CORRODED AT FR 16-19. MX REMOVED AND REPLACED THE FWD FUSE INBD FLOORBEAM IAW EMB 175 SRM 51-40-02, 51-43-01, 51-43-02, 51-41-01. PN 170-03264-001. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR V0XR20120422J0024Floorbeam · corrodedFS 280 FLOORBEAM CORRODED BEYOND SERVICEABLE LIMITS. R & R FS 280 FLOORBEAM, LAW REO 670-53-11-0047 & REO 670-53-11-046 AND SRM 51-42-20, 51-42-06.SDR AALA20120419025Support · corrodedFLOORBEAM SUPPORT CORRODED, BETWEEN FRAME STATIONS 1640 AND 1661 LATERAL "I" BEAMS. REPLACED FLOORBOARD SUPPORT BEAM BETWEEN FRAME STATIONS 1640 AND 1661 AT CENTER LINE 0 WITH NEW FLOORBEAM PER SRM 51-1-02-0G, AND AARD 51-00-05-1, REPAIR 1.SDR AALA20120419017Support · corrodedFLOORBEAM SUPPORT CORRODED BETWEEN STATIONS 1640 AND 1661 AT BUTTLINE 0. INSTALLED NEW SUPPORT PER SRM 51-1-02-0G.SDR AALA20120419016Floorbeam · corrodedCORROSION ON TOP OF LATERAL FLOOR BEAM AT STATION 1660, BUTTLINE 0. REMOVED CORROSION AND INSTALLED DOUBLER PER SRM 53-00-51-2R 5.SDR DALA1229211501Floorbeam · corrodedM/DECK FLOORBEAM STA 1480 WL193 BL 0 CORRODED. REPAIRED PER ERA 501554-14 REV ORIG.SDR USAA2012050300024Strap · crackedQ1 CHECK - CRACK ON FLOORBEAM STABILIZING STRAP AT BS 312, RBL 31. REPLACED FLOORBEAM STABILIZING STRAP AT BS 312, RBL 31 IAW B737 SRM 51-40-02-0G, FIG 12.SDR SWAA2012050103622Floorbeam · crackedLONGITUDINAL FLOORBEAM CRACKED AT BS 616, LBL45. REPAIRED WEB IAW EA.SDR DALA1224993121Floorbeam · corrodedAFT LAV/GALLEY BET FR 68, Y765, FLOORBEAM HAS CORROSION. REMOVED CORROSION IAW A319 SRM 51-74-00. CHECKED LIMITS L=1.9" W=0.87" D=0.027". OUT OF LIMITS IAW A319 SRM 53-00-14 FIG 102. REMOVED AND REPLACED FLOORBEAM IAW A319 SRM 51-42-11.SDR FDEA201204181482Floorbeam · corrodedFLOORBEAM UPPER TEE AT BS 1660 HAS SEVERAL NICKS, GOUGES, AND CORROSION AROUND NUT PLATE HOLES AND VICINITY OF RBL 58. FLOORBEAM WAS FOUND OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL II AND III. ORIGINAL MATERIAL .125 AFTER REWORK .060. R & R FLOORBEAM SDR FDEA201204181481Floorbeam · corrodedFLOORBEAM BS 720 BL 0 TO LBL 70 WL 208.1 UPPER TEE CORRODED. FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51 FIG 101 DETAIL II AND III. ORIGINAL MATERIAL .125 AFTER REWORK .020. REMOVED AND REPLACED FLOORBEAM IAW DWG 143N5015 SH7 AND SRM 51-40-02.SDR FDEA201204181480Floorbeam · corrodedFLOORBEAM UPPER TEE BS 780 LBL 24 TO RBL 25 CORRODED. FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL II AND III. ORIGINAL MATERIAL .125 AFTER REWORK .094. R & R FLOORBEAM IAW DWG 143N5067, SH 1, REV A. MAJOR REPAIR.SDR FDEA201204181479Floorbeam · corrodedFLOORBEAM BS 700 RBL 24 TO LBL 70 WL 208.1 UPPER TEE CORRODED. FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL II AND III. ORIGINAL MATERIAL .125 AFTER REWORK .022. R & R FLOORBEAM IAW DWG 143N5014 SH7 AND SRM 51-40-02. MAJOR REPASDR FDEA201204181478Floorbeam · corrodedFLOORBEAM BS 680 LBL 24 TO RBL 27 UPPER TEE CORRODED. FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL II AND III. R & R FLOORBEAM IAW DWG 143N5013, SH2, REV C AND SRM 51-40-02. MAJOR REPAIR.
Back to JASC 5315