What was found
FLOORBEAM BS 680 LBL 24 TO RBL 27 UPPER TEE CORRODED. FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL II AND III. R & R FLOORBEAM IAW DWG 143N5013, SH2, REV C AND SRM 51-40-02. MAJOR REPAIR.