JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA116860Floorbeam · corrodedDURING SCHEDULED 28Y CHECK, FOUND FLOORBEAM CORRODED AT BS 294, LBL 37. REPAIRED FLOORBEAM PER SRM.SDR FDEA201109304221Floorbeam · crackedFORWARD CARGO COMPARTMENT MAIN DECK FLOORBEAM AT FR31 LBL67 FOUND CRACKED. REPAIR CARRIED OUT AS PER SRM 53-10-15 FIG 212 REVISION 21. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 113.SDR FDEA201109304223Floorbeam · crackedFORWARD CARGO COMPARTMENT MAIN DECK FLOORBEAM AT FR30, LBL 67 FOUND CRACKED. REPAIRED AS PER SRM 53-10-15 FIG 212 REVISION 21. REPAIRED CLASSIFIED AS MAJOR AS PER GMM 6-2-100 REVISION 113.SDR FDEA201109304222Floorbeam · crackedFORWARD CARGO COMPARTMENT MAIN DECK FLOORBEAM AT FR 32 LBL 67 FOUND CRACKED. REPAIRED AS PER SRM 53-10-15 FIG 212 REVISION 21. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 113.SDR FDEA201109304220Floorbeam · crackedFORWARD CARGO COMPARTMENT MAIN DECK FLOORBEAM AT FR27, RBL 27 FOUND CRACKED. REPAIR CARRIED OUT AS PER SRM 53-10-15 FIG 212 REVISION 21. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 113.SDR UALA2011100305312Floorbeam · corrodedFLOORBEAM STA 1640 HAS CORROSION. FLOORBEAM REPAIRED FROM LBL 10 TO RBL 60, PER CO ECRA 5310-05401.SDR AALA20111005AFW01Floorbeam · corrodedCORROSION ON THE UPPER CAP OF THE FUSELAGE MAIN DECK FOORBEAM UPPER CAP AT STATION 347 AND RIGHT BUTTLINE 43 TO 50. REPLACED STRAP PER EA 019143.SDR ASOA201101831Floorbeam · corrodedFLOORBEAM AT FS 349 IS CORRODED BETWEEN RBL 36 AND RBL 45. REPAIRED IAW REO 601R-53-21-2185.SDR SWAA116870Floorbeam · crackedDURING SCHEDULED 16Y CHECK, FOUND LONGITUDINAL FLOORBEAM WEB CRACKED AT BS 706+4, BBL 0.07. REPAIRED WEB IAW SI.SDR UIEA2011102100614Floorbeam · corrodedCORROSION ON FLOORBEAM, BS 1518, LBL 30. REMOVED CORROSION, FOUND OUT OF LIMITS. CUT OUT DAMAGE AND ACCOMPLISHED REPAIR.SDR USAA2011101200013Floorbeam · corrodedC3 CHECK - CORROSION ON FLOORBEAM AT BS 345, LBL 18. REPAIRED FLOORBEAM AT BS 345, LBL 18 IAW B757 SRM 53-00-51-2R-5 FIG 201.SDR DALA1155830694Floorbeam · corrodedMAIN CABIN FLOORBEAM UPPER SURFACE CORRODED STA 1640 LBL 50-57. FORMED 2EA REPAIR ANGLES IAW B757 SRM 53-00-510 REPAIR 5 PG 201 STEP 3 TABLE 1 NOTE D. COMPLIED WITH AT SAA/SAT DURING HMV ON N/R 192492 W/O 89013900001. INSTALLED REPAIR PARTS PER B757 SRM 53SDR SWIA201128008Floorbeam · crackedC-CHECK, FS 274 LBL 12.0 AND RBL 12.0 COCKPIT FLOOR SUPPORT BEAMS ARE CRACKED. REPAIRED PER REO.SDR IPXA1569484Floorbeam · corrodedINSPECTION TYPE:C-CK, FLOORBEAM IS CORRODED AT STA 1040+16, LBL 41, WL 208. FABRICATED AND INSTALLED FLOORBEAM IAW SRM 51-40-02 AND DWG 144N5003 SHEET 4.SDR FDEA201109274161Floorbeam · damagedCABIN FLOORBEAM BS 480, UPPER TEE MISDRILLED RBL 52. REPAIRED IAW SRM 53-00-51 FIG. 201 SH. 1-5, SRM 51-40-02, SRM 51-30-01, DWG 143N8603 AND BAC 1512-426 SPEC. MAJOR REPAIR.SDR UALA2011092705236Floorbeam · damagedTOOLING MARK ON FLOORBEAM WEB AFT SIDE AT STA 310, RBL 44. MAJOR REPAIR ACCOMPLISHED. BLENDED, FABBED AND INSTALLED DOUBLER, ANGLES AND SHIMS PER PEMCO EA PD57-53-197 AND EVA 81339 ON PEMCO NR 3365N00530.SDR UALA2011092705234Floorbeam · corrodedFLOORBEAM AT BS 324 CORRODED AT RBL 44. MAJOR REPAIR ACCOMPLISHED: 324 FLOORBEAM UPPER CHORD REMOVED AND REPAIRED PER THE INSTRUCTIONS ON PEMCO PD 57-53-186 AND EVA 81314 WITHOUT DEVIATION.SDR SWAA116809Floorbeam · corrodedDURING SCHEDULED 28Y CHECK, FOUND FLOORBEAM CORRODED AT BS 312, BETWEEN LBL 13 TO RBL 40. REPAIRED BEAM PER SRM.SDR SWAA116808Floorbeam · corrodedDURING SCHEDULED 8Y CHECK, FOUND FLOORBEAM CORRODED AT BS 967, RBL 50. REPAIRED BEAM PER EA.SDR COMA2011092790029Floorbeam · corrodedFS 280 CROSS BEAM CORRODED ALONG TOP SURFACE OF UPPER ANGLE. REMOVED AND REPLACED FS 280 FLOORBEAM IAW TASK CARD REO-B-53R0005.SDR ASOA201101971Floorbeam · crackedCRACKED TEE ON FS 280 FLOORBEAM. REMOVED TEE BRACKETS, ALL WORK DONE IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. INSTALLED NEW TEE BRACKETS IAW SRM 51-42-21, MINOR REPAIR.SDR DALA1155413713Floorbeam · corrodedFLOORBEAM CORRODED STA 328. REPAIRED FLOORBEAM IAW SRM 53-10-51.SDR DALA1155403713Floorbeam · corrodedFLOORBEAM STA 294.5 CORRODED. REPAIRED PER ERA494553-14.SDR DALA1157070694Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED RBL 7-20 STA 345. ACCOMPLISHED 481634-14MA REV O PERM REPAIR.SDR 7AHR2011092028Floorbeam · corrodedUPPER FUSELAGE FLOOR STRUCTURE HEAVY AMOUNT OF CORROSION UNDER NUTLPLATE ON LOWER CHORD OF FLOORBEAM AT BS 787 AT RBL 24SDR UALA2011092305157Floorbeam · corrodedFLOORBEAM TEE CORRODED AT BS 1661 FROM BL 0 TO LBL15. REPLACED TEE'S AND STRAPS PER SRM.SDR UALA2011092305156Floorbeam · corrodedFLOORBEAM AT BS 345 CORRODED FROM BL 0 - RBL 45. MAJOR REPAIR ACCOMPLISHED REPLACED TEE'S, ANGLES, AND STRAPS PER SRM.SDR ASOA201101793Floorbeam · corrodedFS 280 FWD FLOOR SUPPORT IS CORRODED. INSTALLED NEW SERVICEABLE FS 280 FWD FLOOR SUPPORT ANGLE IAW SRM 51-42-06. THIS REPAIR REQUIERS MAJOR/MINOR CLASSIFICATION IAW ASA SOP 5702. THIS REPAIR IS CLASSIFIED AS A MINOR REPAIR IAW ASA SOP 5702.SDR ASOA201101789Floorbeam · crackedRIGHT OTBD FLOORBEAM ANGLE AT FS 280.00 AND RBL 9.0 IS CRACKED. R & R IAW SRM 51-42-21-001-A01, SRM 51-42-22-001-001-A02 & 51-40-11-001-001-A01.SDR ASOA201101788Floorbeam · corrodedRIGHT FLOORBEAM ANGLE AT FS 280.00 CORRODED. REMOVED CORROSION IAW SRM CH 51-21-06-001-001 STEP 3B NOMINAL THICKNESS IS .063 REMOVED MATEIAL .004 REMAINING THICKNESS IS .059 DAMAGE IS WITHIN LIMITS IAW SRM CH 53-00-00-101-001.SDR ASOA201101787Floorbeam · corrodedLEFT FLOORBEAM ANGLE AT FS 280.00 IS CORRODED. REMOVED CORROSION IAW SRM 51-21-6-001-001, STEP 3B NOMINAL THICKNESS IS .063 REMOVED MATEIAL .003 REMAINING THICKNESS IS .060 DAMAGE IS WITHIN LIMITS IAW SRM 53-00-00-101-001.SDR ASOA201101786Floorbeam · crackedRIGHT INBD FLOORBEAM ANGLE AT FS 280.00 AND RBL 9.0 IS CRACKED. R & R IAW SRM 51-42-21-001-001-A01, SRM 51-42-22-001-001-A01 & SRM 51-40-11-001-001-A01.SDR ASOA201101785Floorbeam · crackedLEFT INBD FLOORBEAM ANGLE AT FS 280.00 AND LBL 9.0 IS CRACKED. R & R IAW SRM 51-42-001-001-A01, SRM 51-42-22-001-001-A01 & SRM 51-40-11-001-001-A01.SDR ASOA201101784Floorbeam · corrodedBS 280 FLOORBEAM IS CORRODED. R & R FLOORBEAM IAW SRM 51-42-06-001-001, 51-42-21-001-001-, 51-42-13-001-001 AND REO 670-53-11-047.SDR ASOA201101783Floorbeam · crackedLEFT OTBD FLOORBEAM ANGLE AT FS 280.00 AND LBL 9.0 IS CRACKED. R & R ANGLE IAW SRM 51-42-21-001-001-A01, SRM 51-42-22-001-001-A01 & SRM 51-40-11-001-001-A01SDR ASOA201101782Floorbeam · corrodedFS 280 FLOOR SUPPORT ANGLE CORRODED. R & R FS 280 FLOOR SUPPORT ANGLE IAW SRM 51-42-06-001-001-A01 & 51-25-00-001-001-A01.SDR 7AHR2011092015Floorbeam · corrodedAFT FUSELAGE FLOOR STRUCTURE HAS CORROSION AT FLOOR SUPPORT BODY STA 957 BETWEEN RT SIDE OF SEAT TRACKS AT RBL 24 AND 45.SDR 7AHR2011092012Floorbeam · corrodedFORWARD CABIN FLOOR STRUCTURE (FRAME) HAS CORROSION AT BODY STA 312 BETWEEN RBL 24 AND RBL 45.SDR IPXA11569777Floorbeam · corrodedINSPECTION TYPE:C-CK, MAIN CARGO COMPARTMENT FLOOR STRUCTURE AT BODY STATION 1681 AND FROM BUTT LINE 0 TO RBL 59, WEB IS CORRODED IN SEVERAL PLACES, MARKED. BLENDED AREAS OF CORROSION AND REPAIRED IAW EA 111312 IR AND EOB757-5310-44716-A.SDR FDEA201109224063Floorbeam · corrodedBS 1070 LOWER FLOORBEAM FLANGE HAS SURFACE CORROSION. REMOVED PREVIOUS REPAIR AT BS 1070 FLOORBEAM LOWER TEE CAP, CUTOUT FLOORBEAM LOWER TEE CAP SECTION BETWEEN LBL 69- RBL 69, FABRICATED FLOORBEAM LOWER TEE CAP REPAIR, SPLICES, AND STRAPS, LOCATED AND DRILLESDR DALA1156130138Floorbeam · corrodedFS 1219 FLOOR FRAME UPPER CHORD IS CORRODED AT LBL 22.5 BEYOND SRM LIMITS. FLOORBEAM UPPER CHORD REPLACED IAW B767-300 SRM 51-10-02 AND INSTALLED IAW B767-300 SRM 51-40-02.SDR DALA1156120138Floorbeam · corrodedFS 1197+66 FLOOR FRAME UPPER SURFACE CORRODED AT RBL 42 BEYOND LIMITS OF SRM. FLOORBEAM UPPER CHORD REPLACED PER B767-300 N SRM 51-10-02 AND INSTALLED PER B767-300 SRM 51-40-02.SDR UALA2011092305131Floorbeam · damagedLEFT CABIN FLOORBEAM, BS 984, HAS TOOLING MARKS AT INBD END AND FWD UPPER EDGE. REPAIRED PER EC-RA 5310-05 402. DAMAGE REMOVED, TREATED AND PRIMED.SDR UALA2011092305130Floorbeam · corrodedFLOORBEAM CORRODED AT STA 324 RBL 38 UP TO CREASE BEAM. MAJOR REPAIR ACCOMPLISHED REPAIRED STRAPS AND REPAIRED ANGLES PER EC-RA 5310-05399. THIS IS A CAT B RPR. ALSO REF EVA 81311. N-R 9949355.SDR SWAA116727Floorbeam · corrodedDURING SCHEDULED 6Y CHECK, FOUND AFT CARGO FLOORBEAM CORRODED BETWEEN BS 771 TO BS 773, RBL 8. REPAIRED BEAM IAW EA.SDR SWAA116726Floorbeam · corrodedDURING SCHEDULED 6Y CHECK, FOUND AFT CARGO FLOORBEAM CORRODED BETWEEN BS 771 TO BS 773, RBL 3. REPAIRED BEAM IAW EA.SDR SWAA116725Floorbeam · corrodedDURING SCHEDULED 6Y CHECK, FOUND AFT CARGO FLOORBEAM CORRODED BETWEEN BS 771 TO BS 773, LBL 3. REPAIRED BEAM IAW EA.SDR SWAA116724Floorbeam · corrodedDURING SCHEDULED 6Y CHECK, FOUND AFT CARGO FLOORBEAM CORRODED BETWEEN BS 771 TO BS 773, LBL 8. REPAIRED BEAM IAW EA.SDR DALA1154960138Floorbeam · corrodedFS 1219 FLOOR FRAME UPPER CHORD IS CORRODED AT BL L22.5 BEYOND SRM LIMITS.SDR DALA1154950138Floorbeam · corrodedFS 1197 +66 FLOOR FRAME UPPER SURFACE IS CORRODED AT RBL 42 BEYOND LIMITS OF SRM.
Back to JASC 5315