What was found
LEFT FLOORBEAM ANGLE AT FS 280.00 IS CORRODED. REMOVED CORROSION IAW SRM 51-21-6-001-001, STEP 3B NOMINAL THICKNESS IS .063 REMOVED MATEIAL .003 REMAINING THICKNESS IS .060 DAMAGE IS WITHIN LIMITS IAW SRM 53-00-00-101-001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT FLOORBEAM ANGLE AT FS 280.00 IS CORRODED. REMOVED CORROSION IAW SRM 51-21-6-001-001, STEP 3B NOMINAL THICKNESS IS .063 REMOVED MATEIAL .003 REMAINING THICKNESS IS .060 DAMAGE IS WITHIN LIMITS IAW SRM 53-00-00-101-001.