JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2024081298196Floorbeam · corroded*SDR FILED OPEN* FAULT - CORROSION - CHORD, MAIN DECK FLOOR BEAM UPPER CHORD, STA 880 LBL 78 (REPAIR) COMPLETED RII EI NO.F2024A53M-1918 SEQUENCE A STEP 14. REV.0SDR REXA2024072200564Floorbeam · corrodedFS.280.00 RH CROSSBEAM IS CORRODED. REMOVED AND REPLACED RH FS 280.00 CROSSBEAM P/N: CC670-34094-6S, IAW CRJ-900 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01 AND 51-42-22-001-001-A01.SDR REXA2024072200562Floorbeam · corrodedFS.280.00 LH CROSSBEAM IS CORRODED. REMOVED AND REPLACED LH FS 280.00 CROSSBEAM P/N: CC670-34094-1S, IAW CRJ-900 SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01 AND 51-42-22-001-001-A01.SDR SWI2024F00914Floorbeam · corrodedSIGNS OF CORROSION NOTED ON COCKPIT AND CABIN FLOOR LANDINGS ON THE FS280.00 BEAM, LBL9 -RBL9. (C-CHECK RO 10/6/2024) (FILED CLOSED)REMOVED AND REPLACE NEW ANGLE P/N CC670-34095-3S ON COCKPIT FS280.00 BEAM, LBL9 TO RBL9 AND EVALUATED AREA ON CABIN FLOOR LANDINSDR SWIA202409160825Floorbeam · crackedFOUND CRACK ON RBL12 COCKPIT FLOOR BEAM MX 28544268 (C-CHECK RO 9/15/2024) REMOVED DAMAGED SECTION FLOOR BEAM AND PREVIOUS REPAIR PARTS ON RBL 12.00 REF CRJ900 SRM 53-11-43-201-003-A01. INSTALLED NEW SECTION FLOOR BEAM AND PREVIOUS REPAIR PARTS (FOUND OSDR IPXA2024082265029Floorbeam · corrodedCORROSION - CHORD, MAIN DECK FLOOR BEAM UPPER CHORD, STA 640 LBL 97 (REPAIR). REPAIR DAMAGE AREA I.A.W UPS EO-91168-REQ1 REV1 THAT EO ATTACH TO NRC:T3F18E004V3UU. JOB COMPLETEDSDR IPXA2024081965808Floorbeam · corrodedCORROSION - CHORD, MAIN DECK FLOOR BEAM UPPER CHORD, STA 740 LBL 5 ~ 10 (REPAIR). ACCOMPLISHED JOB I.A.W. UPS EO-91144-REQ1 REV.1- JOB COMPLETED.SDR HNAA2024081300678Floorbeam · corrodedE046450 CABIN LH FLOOR BEAM CORRODED AT FRAME 29. ACCOMPLISHED PERMANENT REPAIR ON LH CABIN FLOOR BEAM AT FR 29 IAW EMB145 ETD2024-145-019932 AND EO1-53-24-0455SDR HNAA2024081300676Floorbeam · corrodedE046443 CABIN CENTER FLOOR BEAM UPPER FLANGE CORRODED AT FRAME 26. RAR CABIN CENTER FLOOR BEAM UPPER FLANGE (GUSSET) AT FRAME 26 IAW EMB 145 SRM 51-40-02SDR IPXA2024081265029Floorbeam · corroded*SDR FILED OPEN* FAULT - CORROSION - CHORD, MAIN DECK FLOOR BEAM UPPER CHORD, STA 640 LBL 100 (REPAIR) OK TO WORKSDR CALA2024073002142Floorbeam · corrodedCABIN - STA 303 LBL 44 FLR BEAM FOUND CORRODED AS MARK TRANSFER REF. NON-ROUTINE HX NRC WO.3322377. CABIN STA 303 FLOOR BEAM LBL 6 TO LBL 63 REPAIRED AS PER ECRA 5310-08370 REV ORIG. ATTACH MAINTENANCE WORKSHEET FORM 44-0008 ITEM 1 TO ITEM 31 ACCOMPLISHED. (CSDR DALA2024072207359Floorbeam · corroded(LOG 0454924) CORROSION ON FLOOR SUPPORT WL-208, STA-947.5+4, FROM RBL-50 TO RBL-54. REPLACED AND INSTALLED NEW INTERCOSTAL(FLOOR SUPPORT) BTW STA 947 TO STA 967 RBL 50 WL-208 IAW B737-800 SRM 51-40-02-OG AND DRAWING 147A5660.SDR DALA2024072207358Floorbeam · corroded(LOG 0454920) CORROSION ON FLOOR SUPPORT WL-208, STA-947.5+4, FROM RBL-34 TO RBL-50. REPLACED AND INSTALLED NEW FLOOR SUPPORT ON STA 947.5+ 4" BTW LBL 27-49LBL WL-208 IAW B737-800 SRM 51-40-02-OG AND DRAWING 147A56450.SDR CALA2024072202076Floorbeam · corroded(B737-53-3-0737) MAIN CABIN FLOOR BEAM UPPER SURFACE IS CORRODED AT STA 1016 APPROX RBL35. TRANSCRIBED FROM HAECO GSO NRC 9288545.SDR VNAA20240718001Floorbeam · gougedFS280 WL72 LBL40 1) ANGLE COMMON TO FS280 FLOOR BEAM AND AFT INTERCOSTAL HAS BARE METAL / TOOL MARK. 2) SAME ANGLE HAS MATERIAL GOUGED OUT AT THE LWR EDGE COMMON TO BEND RADIUS. REPAIRED BY FABRICATING AND INSTALLING REPLACEMENT CLEAT (ANGLE) P/N: SH670-31736-SDR SWI202408190692Floorbeam · corrodedAFT WET AREA FLOOR STRUCTURE HAS CORROSION ON LH I/B BEAM AT FR 87 AS MARKED. (C-CHECK RO 8/19/2024) REMOVED AND REPLACED AFT WET AREA FLOOR STRUCTURE LH I/B BEAM AT FR 87 REF. EMB SRM 51-40-08 NO CHANGE TO WEIGHT AND BALANCESDR SWIA2024081900717Floorbeam · corrodedAFT WET AREA FLOOR STRUCTURE HAS CORROSION ON RH I/B BEAM AT FR 87 AS MARKED. (C-CHECK RO 8/19/2024) REMOVED AND REPLACED AFT WET AREA FLOOR STRUCTURE RH I/B BEAM AT FR 87 REF. EMB SRM 51-40-08SDR DALA2024072207345Floorbeam · corroded(LOG 0454108) CORROSION ON FLOOR SUPPORT ANGLE WL-208, STA-986+6.5, FROM RBL-37 TO RBL-45. REMOVED AND REPLACED FLOOR SUPPORT ANGLE IAW B737 SRM 51-40-02-OG AND DWG 147A5700.SDR AALA202407224152Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR SUPPORT BREAK ASSEMBLY AT STA 540 FROM LBL 0 TO LBL 20. REPLACED BREAK ASSEMBLY PANEL PER AARD 51-00-05-1 AND SRM 51-40-02.SDR AALA202407220757Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR SUPPORT BREAK ASSEMBLY AT STA 540 FROM RBL 0 TO RBL 20. REPLACED BREAK ASSEMBLY PANEL PER AARD 51-00-05-1 AND SRM 51-40-02.SDR DALA2024071907283Floorbeam · corroded(LOG 0452593) CORROSION ON FLOOR SUPPORT ANGLE WL-208, STA-986+5.5, FROM LBL-38 TO LBL-44. REMOVED, REPLACED AND INSTALLED FLOOR SUPPORT ON STA 986.5+6" BTW LBL 38 TO LBL44 IAW B737-800 SRM 51-40-02-OG AND DWG 147A5700.SDR N6WA2024071702Floorbeam · corrodedRH SIDE FS280 BEAM IS CORRODED. REMOVED AND REPLACED RH SIDE FS280.00 BEAM IAW CRJ SRM 51-42-00SDR N6WA2024071701Floorbeam · corrodedLH SIDE FS280 BEAM CORRODED. REMOVED AND REPLACED LH SIDE OF FS280 BEAM IAW CRJ SRM 51-42-00.SDR AALA202408050153Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON UPPER CHORD OF PASSENGER CABIN FLOOR BEAM AT STA 947, LBL 5. FLOORBEAM UPPER CHORD REPLACED PER SRM 53-70-51-2R-5..SDR ASAA2024071551193Floorbeam · corrodedMAIN CABIN FLOORBOARD SUPPORT HAS CORROSION AT BS270 BETWEEN RBL0 AND RBL7 AS MARK. GROUNDED - YES. REMOVED CORROSION IAW B737-800 SRM 51-10-02, ORIG THICKNESS FOR TOP SURFACE .100 REMOVED .007 REMAINING MAT .093 FOUND TO BE IN LIMITS IAW B737-800 SRM 53-10-51SDR SWIA2024091670014Floorbeam · corrodedCORROSION FOUND AT FS280 LH CROSSBEAM CAMP 28527638 (C-CHECK RO 9/15/2024) INSTALLED NEW LH CROSSBEAM AT FS 280.00 REF CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-22-001-001-A01, CRJ900 SRM 51-42-13-001-001-A01 AND DWG CC670-34010 REV -K. COMPLIESDR REXA2024073000597Floorbeam · crackedCRACKED LH FS 280 COCKPIT FLOOR BEAM AT LBL 12.50. COMPLIED WITH REO NO. 690-53-11-1805. DATED: 2024-07-15. REV --SDR SWIA20240920027Floorbeam · corrodedCABIN FLOOR LEFT T CAP LBL27 BETWEEN APPROXIMATELY FS1000.00 AND FS1050.00 CORRODED AS MARKED (C-CHECK RO 9/19/2024) COMPLIED WITH REPAIR TO THE CABIN FLOOR BEAM AT LBL27, APPROX FS1000 - FS1050 REF REO 670-53-61-2337 REV -A 2024-08-22 AND CRJ-700 SRM SDR SWIA20240920026Floorbeam · corrodedCABIN FLOOR RIGHT T CAP RBL9 BETWEEN FS1007.00 AND FS1045.00 CORRODED AS MARKED (C-CHECK RO 9/19/2024) COMPLIED WITH REPAIR TO THE RBL9 FLOOR BEAM AT FS1007 - FS1045 REF CRJ-700 SRM 53-00-41-201-001-A01, REO 670-53-61-2340 REV -- 2024-08-06, AND REO 670SDR VNAA202409010020Floorbeam · corrodedCORROSION ON FLOOR SUPPORT FS=281 BETWEEN STGR 25LH TO 25RH AT MAIN AVIONICS COMPARTMENT. FLOOR SUPPORT FS=281 BETWEEN STGR 25LH TO 25RH AT MAIN AVIONICS COMPARTMENT WAS REPLACED PER CRJ900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01SDR VNAA202409010011Floorbeam · corrodedCORROSION ON FLOORBEAM FS280 (RBL9 TO LBL9) AT CABIN FLOOR STRUCTURE. FLOORBEAM FS280 (RBL9 TO LBL9) AT CABIN FLOOR STRUCTURE IT IS OUT OF LIMITS PER CRJ900 SRM 53-00-00-101-001-A01 THEREFORE WAS REPLACED PER CRJ900 SRM 51-42-06-001-001-A01 AND SRM 51-42-10-SDR SWAA2024082211852Floorbeam · corrodedCORROSION ON FLOOR BEAM BS 986.5 AND RBL 43 WL 208.1 AT AFT GALLEY AREA 2024-443520<[01] TOOL USED: ULTRASONIC EQUIPMENT; P/N: 45 MG; S/N: 130064101; DUE DATE: 13-DEC-24.;[02] TOOL USED EDDY CURRENT EQUIPMENT PN:NORTEC 600D; SN?210138003; DUE DATE:11-JUN-25.;[SDR AALA202408205328Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM +Y1292 LOCATED AT LEVEL FR 16 IN FORWARD GALLEY AREA. REPLACED FLOOR BEAM +Y1292 PER SRM 51-42-11-801.SDR AALA202408131188Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM LOCATED AT +Y765 AT LEVEL FR16 IN FORWARD GALLEY AREA. REPLACED FLOOR BEAM PER SRM 51-42-11-801.SDR SWAA2024080912015Floorbeam · corrodedAFT WET AREA HAS A BEAM CORRODED AT THE DOMENUT ATTACHMENT POINT STA 986.5 AND LBL 48 APROX. DOT 82-003. AFT WET AREA HAS A BEAM CORRODED AT THE DOMENUT ATTACHMENT POINT STA 986.5 AND LBL 43 APROX. DOT 82-003.<[01] ACCOMPLISHED STA 986.5 LBL 43 FLOOR BEAM CATESDR SWAA2024080911826Floorbeam · corrodedMAIN CABIN AFT WET AREA FLOOR BEAM UPPER SUFACE STA 986.5 RBL 28'' CORROSION.DOT 002<[01] ACCOMPLISHED MAIN CABIN FLOOR BEAM STA 986.5 RBL 28'REPAIR AS PER EA -21-153-00612. REF TO TTG8Q00ULPTH.;[02] CORRECTION STEP #1 ACCOMPLISHED MAIN CABIN FLOOR BEAM STA 98SDR AALA202408053969Floorbeam · corrodedAIRCRAFT WAS IN BASE MAINTENANCE: CORROSION AFT GALLEY FLOOR BEAM BETWEEN FR 68 AND FR 69 AT -Y1162. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR AALA202407315872Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION AFT CABIN FLOOR BEAM AT FR 66 AND -Y1732. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR AALA202407314900Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION AFT CABIN FLOOR BEAM AT FR 68 AND -Y1162. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR DALA2024071707213Floorbeam · corrodedSHIP 3275 DISC: CORROSION FLOOR BEAM +Y765 LOCATED AT FR 20 AT FWD GALLEY AREA ( SSI 531189). C/A: REPLACED FLOOR BEAM Y765 LOCATED AT FR 20 AT FWD GALLEY AREA AS PER A320 SRM 51-42-11 AND SRM 51-72-11 DWG D53110920 ,ISSUED E00 , RELEASE DATE :28-APR-21 , DWG SDR SWIA20240920025Floorbeam · corrodedL/H FLOOR BEAM LBL 9 HAS CORROSION APPROXIMATELY BETWEEN FS549.00 TO FS565.00 (MARKED) (C-CHECK RO 9/19/2024) PERFORMED FLOOR BEAM SPLICE REPAIR APPROX. FS549.00 TO FS565.00 REF REO 670-53-31-916 REV -- 2024-08-12, REO 670-53-31-918 REV -- 2024-08-12 ASDR AALA202409137582Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR BEAM HAS CRACKED ZONE 1 FASTENER HOLE AT THE CENTER WING BOX FRONT SPAR COMMON TO VERTICAL STRINGER 3 AT FR 36 AND +Y254. REPAIRED FLOOR BEAM PER EA 356296.SDR AALA202409134349Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR BEAM HAS 2 CRACKED FASTENER HOLES AT THE CENTER WING BOX FRONT SPAR COMMON TO VERTICAL STRINGER 4 AT FR 36 AND -Y254. REPAIRED FLOOR BEAM PER EA 356296.SDR AALA202409133465Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR BEAM HAS 2 CRACKED FASTENER HOLES AT THE CENTER WING BOX FRONT SPAR COMMON TO VERTICAL STRINGER 2 AT FR 36 AND +Y765. REPAIRED FLOOR BEAM PER EA 356296.SDR AALA202409135914Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR BEAM HAS CRACKED ZONE 2 FASTENER HOLE AT THE CENTER WING BOX FRONT SPAR COMMON TO VERTICAL STRINGER 3 AT FR 36 AND +Y254. REPAIRED FLOOR BEAM PER EA 356296.SDR AALA202407244626Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM AT FR 68 AND -Y464.8. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR FDEA202407110984Floorbeam · crackedMDC FLOOR SUPPORT STRUCTURE HAS CRACK AND MISSING NUT PLATE LOCATED AT STA 1020 BET RBL 25 AND RBL 45. FUSELAGE-MAINFRAME-MAIN CARGO FLOOR SUPPORT STA 1020 CRACKED, NEW PART FABRICATION-TEMPER ALTERATION, ACCOMPLISHED STEPS 1-2 WITHOUT NO DEVIATION IAW E.ASDR VNAA202409010012Floorbeam · corrodedCORROSION ON RH CROSSBEAM FS 280 AT COCKPIT CABIN FLOOR. CORROSION ON RH CROSSBEAM FS 280 AT COCKPIT CABIN FLOOR WAS EVALUATED OUT LIMITS PER CRJ-900 SRM 53-00-00-101-001-A01 THEREFORE RH CROSSBEAM FS 280 WAS REPLACED PER PER CRJ-900 SRM 51-42-06-001-001-A01,SDR VNAA202409010009Floorbeam · crackedCRACKED CENTER COCKPIT FLOOR BEAM RBL12 AT FS 280.00 FLOOR INTERNAL SUPPORT STRUCTURE BELOW FLIGHT COMPARTMENT. CENTER COCKPIT FLOOR BEAM RBL12 AT FS 280.00 FLOOR INTERNAL SUPPORT STRUCTURE BELOW FLIGHT COMPARTMENT WAS REPAIRED PER REO 690-53-11-1808. REV.--SDR VNAA202407120043Floorbeam · corrodedHN147962 DISCREPANCY: RBL 9.00 FLOOR BEAM IS CORRODED AT F.S. 1031.00. CORRECTIVE ACTION: REPAIRED DAMAGE I.A.W. BOMBARDIER CRJ700 SRM REPAIR 53-41-201-001-A01 AND MHIRJ REO 670-53-61-2254 REV.--, DATED 2024-04-05
Back to JASC 5315