As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CABIN AFT WET AREA FLOOR BEAM UPPER SUFACE STA 986.5 RBL 28'' CORROSION.DOT 002<[01] ACCOMPLISHED MAIN CABIN FLOOR BEAM STA 986.5 RBL 28'REPAIR AS PER EA -21-153-00612. REF TO TTG8Q00ULPTH.;[02] CORRECTION STEP #1 ACCOMPLISHED MAIN CABIN FLOOR BEAM STA 986.5 RBL 28'REPAIR AS PER EA -21-153-00612. REF TO TTG8Q00UP0BN.;[03] VERIFIED STEP 2.