JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA000631Floorbeam · corrodedDURING SCHEDULED D CHECK, FOUND BS 947 FLOOR BEAM UPPER SURFACE CORRODED, RBL 5 AND RBL 48. REPAIRED BEAM PER SRM.SDR CALA0000392Floorbeam · chafedINSPECTION FOUND LOWER SIDE OF FLOORBEAM ANGLE CHAFED IN FORWARD CARGO COMPARTMENT AT STA 370, BL 0. A NEW ANGLE AND REPAIR DOUBLER WERE INSTALLED IAW SRM 53-05, FIGURE 86.SDR CALA0000391Floorbeam · chafedINSPECTION FOUND LOWER SURFACE OF CABIN FLOORBEAM CHAFED IN AFT CARGO PIT OVERHEAD AT STA 1174. THE CHAFED AREA WAS BLENDED IAW SRM 53-05, FIGURE 86. DOUBLERS WERE INSTALLED IAW SRM 53-05, FIGURE 86, 51-10-4 AND 51-10-3.SDR CALA0000381Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORT CORRODED AT FS 1130, LBL 48. THE FLOOR SUPPORT WAS REMOVED AND REPLACED IAW SRM 51-30-2.SDR CALA0000380Floorbeam · corrodedINSPECTION FOUND FLOOR SUPPORTS CORRODED FROM STA 180 - 200, RBL 44 TO RBL 8 AND AT STA 200, LBL 12. THE FLOOR SUPPORTS WERE REMOVED AND REPLACED IAW SRM 51-30-2.SDR MWEA00232Floorbeam · chafedCABIN FLOORBEAM HAS CHAFES AT STATION 484 INBOARD OF LEFT HAND INBOARD SEAT TRACK. FABRICATED AND INSTALLED REPAIR ANGLE AND WEAR STRIPS.SDR AT0000271Floorbeam · corrodedFOUND CABIN BS 967 RBL 48-46 FLOORBEAM TOP CAP CORRODED IN SEVERAL PLACES. FABRICATED AND INSTALLED PARTS, IAW DWG NR 65C37472, 65C37528, AND 65C37522.SDR RRXA001943Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOORBEAM AT STA 1300 LT UPPER CHORD LBL 52 INCHES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 5SDR RRXA001808Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOORBEAM LT UPPER CHORD AT STA 1300 AND LBL 52, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND SDR SWAA000605Floorbeam · corrodedDURING SCHEDULED HALF D CHECK, FOUND BS 294 FLOOR BEAM UPPER SURFACE CORRODED, LBL11 TO RBL 27. REPAIRED BEAM PER SRM.SDR COMA0060307Floorbeam · corrodedLBL 27 FLOORBEAM CORRODED BEYOND LIMITS BETWEEN FS 324.00 AND FS. 349.00. FLOORBEAM REPAIRED IAW REO 601R-53-00-027.SDR RRXA002405Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM BETWEEN STA 270 - 225 AND RBL 45.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAWSDR RRXA002372Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM BETWEEN STA 270 - 225 AND RBL 28.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAWSDR RRXA002371Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE LONGITUDINAL FLOORBEAM AT STA 270 - 225 RT AND RBL 45.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DSDR RRXA02256Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE LONGITUDINAL FLOORBEAM AT RBL 28 1/2 10 BETWEEN STA 270 - 225 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED MISDRILLED HOLES ISDR GAIA00160Floorbeam · crackedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND BODY STATION 740, FLOORBEAM HAS CRACK EXTENDING BEYOND STOP DRILL AT RBL 25 ON UPPER CHORD. REPAIRED IAW SRM 51-10-1. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR AT0000206Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOORBEAM AT BS 996 LBL 45 CORRODED BEYOND LIMITS. REPLACED UPPER ANGLE AT BS 996 LBL 45 IAW DC9 SRM 51-01, 51-30-02, 51-30-05, AND 51-30-04.SDR AT0000200Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOORBEAM AT BS 996 LBL 25 AND LBL 45 TO BE CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPLACEMENT ANGLE IAW DC9 SRM 51-30-02, 51-30-05, 51-10-04, 51-10-03, AND 20-16.SDR 00FDEA00211Floorbeam · damagedUPPER CARGO COMP SEAT TRACK SUPPORT BEAM AT BS 919, 939, 959, 999 & 1019 FOUND TRACK ATTACH HOLES ELONGATED AFT SEAT TRACK REMOVED (LBL 47.5). *S/D* REMOVED AND REPLACED PER EA 8-5310-49609 THRU 49612.SDR SWAA000604Floorbeam · crackedDURING SCHEDULED HALF D CHECK, FOUND BS 787 FLOOR BEAM CRACKED, RBL 14. REPAIRED FLOOR BEAM PER SRM.SDR 00FDEA00203Floorbeam · corrodedCORROSION ON UPPER CHORD OF FLOORBEAM AT BS 1130, LBL 18.5, WL 208 (C53-224-01). *S/D* REMOVED AND REPLACED PER FEDEX 51-30-2, 51-20-4 SRM & FEDEX EA 7-5310-50036.SDR AWXA0000207Floorbeam · corrodedC-CHECK, CORROSION LEVEL 1, CORRODED FLOORBEAM FS 967 RBL 41 AT CLIP NUT. REPAIRED DAMAGED AREA IAW 737 SRM 53-00-51 PG 207, MAT USED NOT AVAILABLE REFER TO SRM.SDR AWXA0000206Floorbeam · corrodedC-CHECK, CORROSION LEVEL 1, CORRODED FLOORBEAM FS 986.5 LBL 42 RBL 42 AT CLIP NUTS. REPAIRED DAMAGED AREA IAW 737 SRM 53-00-51 FIG 202. FABRICATED NEW T CAP IAW 53-00-51, MAT USED NOT AVAILABLE REFER TO SRM.SDR AWXA0000205Floorbeam · corrodedC-CHECK, CORROSION LEVEL 1, CORRODED FLOORBEAM UPPER FLANGE FS 1006 RBL 10. REPAIRED DAMAGED AREA IAW 737 SRM 53-00-51 FIG 202. FABRICATED UPPER T CAP IAW 737 53-00-51 FIG 202, MAT USED NOT AVAILABLE REFER TO SRM.SDR AWXA0000204Floorbeam · corrodedC-CHECK, CORROSION LEVEL 1, CORRODED FLOORBEAM FS 967 RBL 28 AT CLIP NUT LOCATIONS. REMOVED AND REPAIRED DAMAGED AREA IAW 737 SRM 53-00-51 FIG 203, FABRICATED STRAP FRM 7075T6 .125 IAW 737 SRM 53-00-51 PG 212. TREATED AND PRIMED PARTS IAW 737 SRM 51-21-00.SDR AWXA0000201Floorbeam · corrodedC-CHECK, CORROSION LEVEL 2, CORRODED FLOORBEAM UPPER FLANGE STA 1016 LBL 29 (PREVIOUS BLEND BEYOND LIMITS). UPPER FLANGE REPLACED ON JT 1077, FABRICATED STRAP FROM 7075T6 .125 IAW 737 SRM 53-00-51 FIG 203.SDR AWXA0000199Floorbeam · corrodedC-CHECK, TOP FLOORBEAM AT FS 986 BL 0 TO LBL 18 CORRODED OUT OF LIMITS. REMOVED DAMAGED T CHORD IAW 737 SRM 51-40-02, FABRICATED AND INSTALLED REPLACEMENT CHORD IAW 737 SRM 53-00-51 FIG 202 AND SRM 51-20-1, MAT USED (BAC 1505-100617). TREATED AND PRIMED IAW SDR AWXA0000190Floorbeam · corrodedC-CHECK, CORROSION ON UPPER T CHORD OF FLOORBEAM AT FS 947 RBL 20 OUT OF LIMITS. REMOVED DAMAGED AREA IAW 737 SRM 53-00-51, FABRICATED REPAIR PARTS FROM (T-CHORD BAC 1505 -100617 7075T6, SUPPORT ANGLE BAC 1490-2236 7075T6, STRAPS .063 AND .071 7075T6). TREATSDR MWEA00200Floorbeam · misdrilledSTATION 160 FLOORBEAM HAS 3 NUT PLATE HOLES THAT ARE ELONGATED AT X=-18 + X=-29 + X=-47. FABRICATED AND INSTALLED NEW FLOORBEAM AND SPLICES.SDR RRXA002230Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1060 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED L ANGLE IAW EO NR 00-047 WITH APPROVEDSDR USAA000506Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH, STATION 986, RBL 14 UPPER CHORD FLOORBEAM. REPLACED NEW T-CAP PER TR 53-10-05A. (M)SDR GAIA00127Floorbeam · corrodedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND CORROSION ON FLOORBEAM BS 620 AT SEAT TRACK LBL 25. REPAIRED IAW SRM 53-10-4. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00133Floorbeam · corrodedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND CORROSION ON FLOORBEAM UPPER CHORD LOWER SURFACE, BOTH FORE AND AFT SIDES AT STATION 460, RBL 48. REPAIRED FLOORBEAM UPPER CHORD IAW SRM 53-10-8. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00145Floorbeam · corrodedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND FLOORBEAM AT STATION 1130, RBL 10, HAS CORROSION UNDER NUTPLATE. REMOVED CORROSION AND REPAIRED IAW TIMCO REPAIR ENGINEERING ORDER REO NR S00066. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00146Floorbeam · corrodedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND FLOORBEAM AT STATION 1130, RBL 38-45, HAS CORROSION UNDER TWO NUT PLATES. REMOVED CORROSION AND REPAIRED IAW TIMCO REPAIR ENGINEERING ORDER REO NR S00066. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00147Floorbeam · damagedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND BS 360, LBL 25 UPPER CHORD HAS DAMAGED FASTENER HOLES. REPAIRED IAW SRM 53-10-8. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00149Floorbeam · corrodedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND CORROSION ON FLOORBEAM, UPPER CHORD LOWER SURFACE, FORE AND AFT SIDES AT STATION 440, RBL 48. REPAIRED IAW SRM 53-10-8. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00152Floorbeam · corrodedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND FLOOR SUPPORT ANGLES HAVE CORROSION AT BS 312 RBL 40 AND RBL 42. REMOVED CORROSION AND REPAIRED IAW SRM 53-10-8. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00154Floorbeam · damagedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND UPPER CHORD AT BS 600, LBL 25 HAS CUT MARK ON CENTER LINE. REPAIRED IAW SRM 53-10-8. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00155Floorbeam · crackedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND BS 740, FLOORBEAM HAS CRACK EXTENDING BEYOND INBOARD STOP DRILL ON UPPER CHORD AT RBL 45. REPAIRED IAW SRM 53-10-2. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00159Floorbeam · crackedDURING HEAVY C-CHECK AT TIMCO/OSC, FOUND BODY STATION 740, FLOORBEAM UPPER CHORD CRACKED AT LBL 46. REPAIRED IAW SRM 51-10-2. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR USAA000505Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED .5 INCH BY .5 INCH, STATION 967, LBL 6 TO RBL 53. INSTALLED STRAPS PER EA 66921. CORROSION LEVEL 2. (M)SDR DHL200080488CBulkhead · damagedAFT BAGGAGE COMPT BULKHEAD SHOWS FILLET BROKEN AT STA 980.000 LT & RT. REMOVED FASTENERS PER SRM 51-1-21. FABRICATED LINING SUPPORT ANGLE PER SRM 53-2-0. CLEANED, TREATED AND PRIMED PER SRM 51-1-8. INSTALLED ANGLE WITH NEW FASTENERS PER SRM 51-1-21.SDR QXEA0001033Floorbeam · corrodedPDX - CENTER FLOORBEAM AT FRAME 4900, IS CORRODED BELOW PANEL 37AA AT CAMLOCK . REPAIRED IAW FOKKER SRM 53-01-01, PAGE 5 AND SRM 53-01-01, PAGE 6.SDR AT0000166Floorbeam · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOOR SUPPORT CORRODED BEYOND LIMITS AT BS 180, RBL 1 - 39. CORRECTIVE ACTION: REMOVED, FABRICATED, AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-10-02, 51-10-03, AND 51-30-05.SDR SWAA000600Floorbeam · corrodedDURING SCHEDULED HALF D CHECK, FOUND BS 312 FLOORBEAM UPPER SURFACE CORRODED. LBL 11 TO RBL 21. REPAIRED FLOORBEAM PER SRM.SDR SWAA000597Floorbeam · corrodedDURING SCHEDULED HALF D CHECK, FOUND BS 986.5 FLOORBEAM CORRODED ON UPPER SURFACE, LBL 44. REPAIRED BEAM PER RA 1-A53-2037.SDR 0000679972Floorbeam · corrodedCORROSION ON FLOOR SUPPORT BETWEEN STA 200 AND 218 INBD OF RT SEAT TRACK. REPAIRED PER EA 99-172295 LOG PAGE 1419182.SDR USAA000502Floorbeam · corrodedCLT - FOUND T-CAP FLOORBEAM CORRODED, BS 324, RBL TO RBL . REPAIRED PER EA 66826 ANDEA 66865. (M)SDR USAA000503Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 12 INCHES BY 2 INCHES, STATION 740-730, RBL 64 JUST INBOARD OF R2 DOORSILL. REPAIRED PER BOEING DWG 143N5410 AND SRM 51-40-10. (M)
Back to JASC 5315