What was found
CLT - FOUND FLOORBEAM CORRODED 12 INCHES BY 2 INCHES, STATION 740-730, RBL 64 JUST INBOARD OF R2 DOORSILL. REPAIRED PER BOEING DWG 143N5410 AND SRM 51-40-10. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 12 INCHES BY 2 INCHES, STATION 740-730, RBL 64 JUST INBOARD OF R2 DOORSILL. REPAIRED PER BOEING DWG 143N5410 AND SRM 51-40-10. (M)