JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA990296Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON SURFACE TOP OF FLOORBEAM STATION 1006, CORROSION TASK NR C53-107-02. SPLICED IN NEW 'T' CAP PER SRM 53-10-09 AND EA 64206, R 53-10-13. (M)SDR USAA990291Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH BY .5 INCH AREA OF CORROSION AT STATION 947 RBL 6 ON FLOORBEAM, CORROSION TASK NR C53-107-02. INSTALLED ANGLE PER SRM 53-10-9. (M)SDR USAA990289Floorbeam · corrodedCLT - DURIGN Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF CORROSION ON FLOORBEAM AT STATION 328 LBL 12 AND RBL 1, CORROSION TASK NR C53-107-02. SPLICED IN NEW 'T' CAP PER TR 53-10-13. (M)SDR SWAA990749Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CRACKED FLOORBEAM, BS 772, LBL 17. REPAIRED BEAM PER SRM.SDR SWAA990748Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORROSION AT FLOORBEAMS, BS 772, RBL 3, AND BS 857, LBL 12, AFT CARGO BIN. REPAIRED BEAMS PER SRM AND SWA RA NR 1-A53-2021.SDR RRXA991363Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FLOOR SUPPORT UNDER CLIP NUTS AT STA 1746, BETWEEN BL 7-1/2 RIGHT AND BL 23 1/2 RIGHT AT LONGERON 21 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICASDR RRXA991361Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FLOOR SUPPORT UNDER CLIP NUTS, AT STA 1746, BETWEEN BL 1.5 LEFT AND BL 20.5 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FLOORBEASDR AT9900398Floorbeam · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE FLOORBEAM AT BS 277 LBL 30-32 UPPER FORWARD WEB CORRODED. CUT OUT CORRODED AREA, FABRICATED REPAIR FILLER AND DOUBLER, TREATED, PRIMED AND INSTALLED IAW B737 SRM 51-10-1, 51-10-6, 53-10-1, 51-40-2, 51-21SDR USAA990402Floorbeam · corrodedPIT - DURING Q-4 CHECK, FOUND 1 INCH BY 8 INCH CORROSION AT GALLEY AREA FLOORBEAM NR 44 TOP AND LOWER SURFACE, CORROSION LEVEL 1. FABRICATED FLOORBEAM AND INSTALLED PER SRM 53-11-1. (M)SDR USAA990401Floorbeam · corrodedPIT - DURING Q-4 CHECK, FOUND 1 INCH BY 5 INCH CORROSION AT STATION 218-237 FLOORBEAM CAP AT CENTER, CORROSION LEVEL 1. FABRICATED AND INSTALLED NEW SECTION BY SPLICING PER TYPICAL REPAIR 53-11-21A. (M)SDR USAA990400Floorbeam · corrodedPIT - DURING Q-4 CHECK, FOUND 1 INCH BY 4 INCH CORROSION GALLEY AREA NR 49 FLOORBEAM TOP AND LOWER SURFACES, CORROSION LEVEL 1. MANUFACTURED FLOOR SUPPORT AND INSTALLED SAME PER SRM 53-11-1 TYPE A1 AND A2 FIG 11 SHEET 2, ITEM 10. (M)SDR UPS99829661Floorbeam · damagedINSPECTION TYPE:N/A, FLOORBEAM AT FS 1680 HAS ELONGATED HOLES FOR CENTER FASTENER OF SEAT TRACK AFT END. CLEANED UP HOLES TO .5 PER EO DC8-5310-11039-A.SDR SIMA991113Floorbeam · corrodedDURING CPCP-1 INSPECTION, FOUND FLOORBEAMS 36, 38, 39 AND 40 CORRODED. REMOVED AND REPLACED FLOORBEAMS 36 AND 38 IAW SRM 51-25-02. REPAIRED FLOORBEAMS 39 AND 40 IAW SRM 53-00-00 FIGURE 438. AIRCRAFT RETURNED TO SERVICE. (M)SDR RAAA99B2032Floorbeam · corrodedDURING SCHEDULED C-CHECK, FOUND BS 312 FLOORBEAM UPPER CHORD CORRODED AT LBL 3 THRU LBL 30. REMOVED UPPER CHORD, FABRICATED NEW UPPER CHORD 7075T6 .094 AND REPAIRED SPLICE IAW SRM 53-10-08 FIG 9. TREATED, PRIMED, PAINTED IAW SRM 51-10-06. INSTALLED UPPER CHSDR RAAA99B2031Floorbeam · corrodedDURING SCHEDULED C-CHECK, FOUND BS 344 FLOORBEAM UPPER CHORD AT LBL 25 THRU LBL 60 CORRODED. REPLACED FLOORBEAM UPPER CHORD BS 344 LBL 25 THRU LBL 68 IAW SRM 53-10-08 PG 9.SDR ASAA9940099Floorbeam · corrodedSEA - DURING SI CHECK, FOUND CORROSION AROUND SCREW HOLES ON MAIN CABIN FLOORBEAM T-CP AT STATION 986 AND LBL 17 THROUGH 33. REPAIRED PER SRM 53-60-51, FIG 203. (M)SDR ASAA9940098Floorbeam · corrodedSEA - DURING SI CHECK, FOUND MAIN CABIN FLOORBEAM, BS 360, RLB 20.5 AND 25.5 CORRODED ON UPPER CHORD. REPAIRED PER SRM 53-00-51, FIG 201. (M)SDR ASAA9940097Floorbeam · corrodedSEA - DURING SI CHECK, FOUND MAIN CABIN FLOORBEAM, BS 294.5, RBL 18 TO 50 CORRODED ON UPPER CHORD. REPAIRED PER SRM 53-10-51, FIG 205. (M)SDR ABXA9900356Floorbeam · crackedDURING C-CHECK, FOUND FLOORBEAM WEB CRACKED AT STATION 180, LBL 22. REPAIRED IAW DC9 SRM 53-01.SDR 99ZZZM341Floorbeam · corrodedDURING CPCP-1 INSPECTION, FOUND FLOORBEAMS 36, 38, 39 AND 40 CORRODED. REMOVED AND REPLACED FLOORBEAMS 36 AND 38 IAW SRM 51-25-02. REPAIRED FLOORBEAMS 39 AND 40 IAW SRM 53-00-00 FIGURE 438. AIRCRAFT RETURNED TO SERVICE. (M)SDR 99ZZZM340Floorbeam · corrodedDURING CPCP-1 INSPECTION, FOUND FLOORBEAMS 36, 38, 39 AND 40 CORRODED. REMOVED AND REPLACED FLOORBEAMS 36 AND 38 IAW SRM 51-25-02. REPAIRED FLOORBEAMS 39 AND 40 IAW SRM 53-00-00 FIGURE 438. AIRCRAFT RETURNED TO SERVICE. (M)SDR 99ZZZM339Floorbeam · corrodedDURING CPCP-1 INSPECTION, FOUND FLOORBEAMS 36, 38, 39 AND 40 CORRODED. REMOVED AND REPLACED FLOORBEAMS 36 AND 38 IAW SRM 51-25-02. REPAIRED FLOORBEAMS 39 AND 40 IAW SRM 53-00-00 FIGURE 438. AIRCRAFT RETURNED TO SERVICE. (M)SDR 99FDEA00156Floorbeam · corrodedFOUND FLOORBEAM TO BE CORRODED AT BS 1090, RBL 45, WL 208. *S/D* REMOVED AND REPLACED UPPER FLANGE OF FLOORBEAM PER FEDEX EA 7-5310-45246.SDR AWXA9900155Floorbeam · corrodedCORROSION ON BEAM FS 986.5 LBL 42-46. REMOVED DAMAGED CAP, FABRICATED NEW CAP, TREATED PRIMED AND INSTALLED IAW SRM 53-10-9, SRM 51-10-2.SDR AWXA9900153Floorbeam · corrosionCORROSION ON BEAM FS 1016 LT BL 6 12 AFT LAV GALLEY FLOOR. CUT OUT CORROSION, FABRICATED NEW PARTS, TREATED, PRIMED AND INSTALLED IAW SRM 53-10-09, 51-30-2.SDR AWXA9900151Floorbeam · corrodedEXISTING FLOORBEAM REPAIR AT STA 968.5 RBL 49 CORRODED BEYOND LIMITS. REMOVED EXISTING T-CHORD PER SRM 51-30-2, FABRICATED T-CHORD REPLACEMENT PER SRM 53-10-9 FIG 2, TREATED AND PRIMED PARTS PER SRM 51-10-6 AND INSTALLED REPAIR IAW SRM 51-30-2.SDR 9902211144Floorbeam · crackedDURING M CHECK, FOUND CRACK IN FLOOR I BEAM SUPPORT AT FS 879 AT BL 0. REPAIRED PER EA 11-167434.SDR P5CA9900550Floorbeam · damagedFOUND FLOORBEAM AFT CARGO PIT STA 1800R DAMAGED. REPAIRED PER SRM 51-30-02 AND SRM 51-10-02.SDR CALA9900424Floorbeam · corrodedINSPECTION FOUND CABIN FLOORBEAM UPPER CHORD CORRODED AT STA 344, BL 0 TO LBL 15. THE FLOORBEAM UPPER CHORD WAS REMOVED AND REPLACED IAW SRM 53-10-51, FIGURE 205.SDR UPS99829357Floorbeam · corrodedINSPECTION TYPE:A/CK, CORROSION FOUND AT THE FLOORBEAM BY THE LT SERVICE DOOR. UPON FURTHER INVESTIGATION THE LT CIRCUMFERENTIAL FRAME AT STA 1667 FROM STR 21 TO STR 23 TO HAVE EXTENSIVE CORRISION. *S/D* REMOVED LOWER SECTION OF FRAME, FABED SPLICES AND INSSDR UPS99829356Floorbeam · crackedINSPECTION TYPE:A/CK, CRACK AT FLOORBEAM AFT OF SERVICE DOOR. UPON FURTHER INVESTIGATION FOUND CRACK AT CIRCUMFERENTIAL FRAME AT STA 1680 STR 21 NOT AT FLOORBEAM AS FIRST REPORTED. *S/D* REMOVED DAMAGED SECTION OF FRAME, FABED SPLICES AND INSTALLED REPAIR PSDR UPS99229365Floorbeam · corrodedINSPECTION TYPE:SI, CORROSION ON FLOORBEAM UPPER FLANGE LBL 50 TO RBL 50. REPAIRED FLOORBEAM SRM 53-10-8.SDR UPS99229364Floorbeam · corrodedINSPECTION TYPE:SI, CORROSION (C53-224-01.05-01) ON STA 328 FLOORBEAM UPPER CHORD LBL 50. REPAIRED FLOORBEAM AT STA 328 PER SRM 53-10-8.SDR AALA990557Floorbeam · crackedTUL - FOUND FLOORBEAM UPPER FLANGE CRACKED STATION 740 AT RT INBOARD SEAT TRACK RBL 24. STOPPED DRILLED CRACKS AND INSTALLED DOUBLERS PER SRM 53-10-8 PAGES 18-23. (M)SDR 99FDEA00149Floorbeam · corrodedNR 794 - CORROSION (C53-111-01(3)) ON FLOORBEAM LWR CHORD AT BS 1070, WL 200, LBL 40 - RBL 48. REMOVED AND REPLACED BS 1070 FLOORBEAM IAW FEDEX EA 7-5310-45262A.SDR UPS99829398Floorbeam · corrodedINSPECTION TYPE:C3 FS 180 FLOORBEAM AT RBL 24 IS CORRODED OUT OF LIMITS. REPAIRED FLOORBEAM IAW DH SK840-665.SDR COMA9960211Floor Beam · corrodedCORROSION DAMAGE FOUND ON FLOOR BEAMS LBL 27, LBL 9, RBL 9, AND RBL 27 FROM BS 280.0 TO BS 409.0. REPLACED CORRODED SECTIONS OF FLOOR BEAM IAW REO 601R-53-00-027. PART TC: 13,637. (X)SDR COMA9960210Floor Beam · corrodedFLOOR BEAM PLATES AT BS 349.0 ARE CORRODED. REPLACED PLATES. PART TC: 13,637. REF: OPERATOR CONTROL NR 99ZZZX2622 THROUGH 99ZZZX2624. (X)SDR AU990780Floorbeam · corroded(AUS) FUSELAGE FLOORBEAM LOCATED AT STN 344 LBL 2 CORRODED.SDR 99ZZZX2624Floor Beam · corrodedFLOOR BEAM PLATES AT BS 349.0 ARE CORRODED. REPLACED PLATES. PART TC: 13,637. REF: OPERATOR CONTROL NR COMA9960210, AND 99ZZZX2622 THROUGH 99ZZZX2623.SDR 99ZZZX2623Floor Beam · corrodedFLOOR BEAM PLATES AT BS 349.0 ARE CORRODED. REPLACED PLATES. PART TC: 13,637. REF: OPERATOR CONTROL NR COMA9960210, AND 99ZZZX2622 THROUGH 99ZZZX2624.SDR 99ZZZX2622Floor Beam · corrodedFLOOR BEAM PLATES AT BS 349.0 ARE CORRODED. REPLACED PLATES. PART TC: 13,637. REF: OPERATOR CONTROL NR COMA9960210, AND 99ZZZX2623 THROUGH 99ZZZX2624.SDR SCNA99702Floorbeam · corrodedDURING A HEAVY LINE MAINTENANCE CHECK, THE FLOORBEAM AT STA 380 RBL 24 THROUGH 30 WAS FOUND CORRODED OUT OF LIMITS. REMOVED CORROSION ON FLOORBEAM IAW B727 SRM 531001. CUT DAMAGED AREA OUT, FABRICATED REPAIR PARTS FROM 7075 T6 BAC 14902831, 14902785, 1500510SDR CALA9900410Floorbeam · corrodedINSPECTION FOUND FLOORBEAM UPPER FLANGE OF T CORRODED AT STA 312, LBL 10 TO RBL 30. A NEW FLOORBEAM WAS INSTALLED IAW SRM 53-10-51.SDR ABXA9900314Floorbeam · crackedDURING C-CHECK, FOUND FLOORBEAM CRACKED AT STATION 680, UNDER FLOOR TRACK AT LBL54. REPLACED FLOORBEAM IAW DC9 SRM 51-30-2 AND 51-30-5.SDR SCNA99704Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOORBEAM AT STA 1110 HAS CORRISION OUT OF LIMITS ON THE TOP OF THE FLOORBEAM BETWEEN LT BUTTLINE 24 AND RT BUTTLINE 24. REMOVED CORROSION IAW B727 SRM 531001. FABRICATED NEW FLOORBEAM SUPPORT IAW B727 SRM 531008. TREATSDR RRXA991354Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FLOORBEAM UNDER SEAT TRACK 3 ABOVE LONGERON 32 LEFT AT STA 1700. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR STRAP IAW FAA APPROSDR AALA990573Floorbeam · corrodedTUL - FOUND CORROSION AT FASTENER HOLES FOR CEILIG PANEL ATTACHMENT. REMOVED CORROSION AND REPAIRED PER ESO 11697 DATED 4-9-99 USING 7075T6 .080 1 INCY BY 16.5 INCH OAL. (M)SDR 99ZZZX1789Floorbeam · corrodedDURING A C-CHECK, CORROSION WAS NOTED ON FLOORBEAM STA 400.SDR 99ZZZX1788Floorbeam · corrodedDURING A C-CHECK, CORROSION WAS NOTED ON FLOORBEAM STA 380 AT R-1 DOOR.
Back to JASC 5315