What was found
PIT - DURING Q-4 CHECK, FOUND 1 INCH BY 5 INCH CORROSION AT STATION 218-237 FLOORBEAM CAP AT CENTER, CORROSION LEVEL 1. FABRICATED AND INSTALLED NEW SECTION BY SPLICING PER TYPICAL REPAIR 53-11-21A. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-4 CHECK, FOUND 1 INCH BY 5 INCH CORROSION AT STATION 218-237 FLOORBEAM CAP AT CENTER, CORROSION LEVEL 1. FABRICATED AND INSTALLED NEW SECTION BY SPLICING PER TYPICAL REPAIR 53-11-21A. (M)