JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL73E972301Floorbeam · crackedFLOORBEAM AT FS 520 WAS FOUND CRACKED AT RBL 25 AND LBL 45. REPAIRED PER SB 737-53-1120, R 1.SDR SCNA97360Floorbeam · corrodedDURING HEAVY MAINTENANCE VISIT, FOUND THE FLOORBEAM UPPER CAP CORRODED BEYOND LIMITS AT STATION 344, RBL 68 - LBL 52. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT CAP IAW SRM 51-10-1, AND 51-10-2.SDR USAA970326Floorbeam · corrodedCLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 45 INCH CORROSION AREA UPPER AND LOWER SURFACES OF UPPER T-CAP FLOORBEAM BL 0 - LBL 45 BS 344. CORROSION TASK NR C53-107-01. INSTALLED T-CAP PER REPAIR DOCUMENT SRM 53-10-03 TYPICAL REPAIR SEC 41 FLOORBEAM RESDR SIMA973112Floorbeam · corrodedSAW - DURING D-CHECK INSPECTION MAINTENANCE DISCOVERED FLOORBEAM 35 HAD A HOLE DRILLED IN IT AND MAINTENANCE SPLICED IN A NEW SECTION TO FLOORBEAM 35 IAW SRM 53-00-00 FIGURE 429. MAINTENANCE REMOVED AND INSTALLED FLOORBEAMS 36 AND 38 IAW SRM 51-25-02. AIRCRASDR MZZA97297Floor Beam · corrodedKUL - HNRC: 844633 - Q-CHECK FOUND TRANSVERSE FLOOR BEAM STA 1130 RT LAVATORY RBL 20 UPPER CHANNEL CORRODED. REMOVED CORROSION IAW SRM 51-10-6. FOUND BEYOND LIMITS IAW SRM 51-10-6. DIMENSION 2 INCHES BY 4.5 INCHES BY 0.046 INCH. REPLACED FLOOR BEAM CHORD SDR DLL10972315Floorbeam · damagedTHE RT SIDE OF THE CARGO FLOORBEAM AT FS 609 WAS BADLY DAMAGED BY A SERVICE TRUCK IMPACT. A NEW RT SECTION OF FLOORBEAM WAS SPLICED IN PER ER/A 363044-14, REV A.SDR 97ZZZM1182Floorbeam · corrodedSAW - DURING D-CHECK INSPECTION MAINTENANCE DISCOVERED FLOORBEAM 35 HAD A HOLE DRILLED IN IT AND MAINTENANCE SPLICED IN A NEW SECTION TO FLOORBEAM 35 IAW SRM 53-00-00 FIGURE 429. MAINTENANCE REMOVED AND INSTALLED FLOORBEAMS 36 AND 38 IAW SRM 51-25-02. AIRCRASDR 97ZZZM1181Floorbeam · corrodedSAW - DURING D-CHECK INSPECTION MAINTENANCE DISCOVERED FLOORBEAM 35 HAD A HOLE DRILLED IN IT AND MAINTENANCE SPLICED IN A NEW SECTION TO FLOORBEAM 35 IAW SRM 53-00-00 FIGURE 429. MAINTENANCE REMOVED AND INSTALLED FLOORBEAMS 36 AND 38 IAW SRM 51-25-02. AIRCRASDR UPS97224924Floorbeam · corrodedINSPECTION TYPE-SI, CORROSION ON FLOORBEAM AT STA 277 RBL 1 WL 208. REMOVED DAMAGED SECTION OF FLOORBEAM AND SPLICED NEW SECTION IN IAW SRM 51-40-4.SDR GAIA9761AFloorbeam · crackedDURING INSPECTION OF PSE 53.09.015 WHILE AIRCRAFT WAS IN C-CHECK, A CRACK WAS FOUND ON THE FLOORBEAM AT STATION Y=566 AT X=54.50. THE FLOORBEAM WAS REMOVED AND REPLACED IAW THE DC-9 SRM. (M)SDR GAIA9761Floorbeam · crackedDURING INSPECTION OF PSE 53-09-015 WHILE AIRCRAFT WAS IN C-CHECK, A CRACK WAS FOUND ON THE FLOORBEAM AT STATION Y=566 AT X=54.50. REPLACED FLOORBEAM. (M)SDR USAA970325Floorbeam · corrosionCLT - DURING C-04 CHECK VISUAL INSPECTION, FOUND CORROSION ON THE ENTIRE FLOORBEAM AT STATION 1661. REPAIRED 1661 FLOORBEAM CHORD PER REPAIR DOCUMENT SRM 53-00-51 FIGURE 201, 203 AND PER EA NR 60716. (M)SDR USAA970324Floorbeam · corrosionCLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND CORROSION AT FLOORBEAM STATION 377.7 TOP SURFACE THE LENGTH OF THE ENTIRE BEAM. REPLACED ENTIRE FLOORBEAM PER REPAIR DOCUMENT SRM 53-00-51. (M)SDR USAA970322Floorbeam · corrosionCLT - DURING Q-1 VISUAL CHECK INSPECTION, FOUND CORROSION AROUND THE NUTPLATE HOLES STATION 967 FLOORBEAM LBL 56, RBL 56 T-CAP. CORROSION CARD NR C53-107-02. INSTALLED NEW T-CAP PER REPAIR DOCUMENT 53-10-05. (M)SDR CALA9701589Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED ON UPPER CHORD AT STA 344 FROM LBL 0 TO LBL 20. THE CORRODED AREA WAS CUT OUT, A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-10-8.SDR UPS97824925Floorbeam · corrodedINSPECTION TYPE-C, FLOORBEAM AND WEB CORRODED FS 1700 BL 0. REPAIRED IAW DHC SK-801-128.SDR UPS97224901Floorbeam · corrodedINSPECTION TYPE-SI, CORROSION UPPER FLANGE OF FLOORBEAM BS 560 WL 208 RBL 45 TO 55. REMOVED UPPER FLANGE AND SPLICED IN REPAIR SECTION IAW SRM 53-10-8.SDR UPS97224900Floorbeam · corrodedINSPECTION TYPE-SI, CORROSION UPPER FLANGE OF FLOORBEAM BS 560 WL 208 LBL 2 TO LBL 25. REMOVED DAMAGE SECTION AND SPLICED IN NEW SECTION OF FLOORBEAM UPPER CHORD IAW SRM 53-10-8.SDR DL72S972321Floorbeam · corrodedSTA 344 FLOORBEAM CORRODED LEFT TO RIGHT SIDES. REPAIRED PER SRM 51-10-8 FIG 11.SDR DL72S972272Floorbeam · corrodedCABIN FLOOR BEAM CORRODED STA. 380 LBL14 TO RBL60. REPAIRED PER SRM 53-10-1 FIG. 4.SDR CALA9701582Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 986.5 FROM L-2 TO R-2 DOOR. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51 AND ECRA 5310-03450.SDR 97ZZZX4984Floor Beam · corrodedDURING C-CHECK, CORROSION WAS NOTED ON UPPER CHORD FLOOR BEAM STA 420 BETWEEN RBL 12 AND LBL 14.SDR 97ZZZX4983Floor Beam · corrodedDURING C-CHECK, CORROSION NOTED ON UPPER CHORD FLOOR BEAM STA 480 BETWEEN RBL 65 AND LBL 24.SDR 97ZZZX4929Floor Beam · corrodedDURING C-CHECK, CORROSION NOTED ON UPPER T-CHORD FLOOR BEAM STA 328 AT LBL 55.SDR 97ZZZX4925Floor Beam · corrodedDURING C-CHECK, CORROSION NOTED ON CABIN FLOOR BEAM UPPER CHORD AT STA 380 FROM RBL 20 TO RBL 45.SDR 97ZZZX4918Floor Beam · corrodedDURING C-CHECK, CORROSION NOTED ON CABIN FLOOR BEAM STA 1130, OUTBOARD OF RBL 24.SDR 97ZZZX4915Floor Beam · corrodedDURING C-CHECK, CORROSION NOTED ON CABIN FLOOR BEAM UPPER CHORD FROM LBL 55 TO RBL 42.SDR CALA9701570Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT BS 312, BL 0 TO RBL 15. THE FLOORBEAM WAS REPAIRED IAW SRM 53-10-51 PAGE 221, FIGURE 205.SDR ASAA9710101Floorbeam · corrodedSEA - DURING C-CHECK, FOUND CORROION ON THE AFT FLANGE UPPER SURFACE OF THE FLOORBEAM, AROUND THE NUTPLATE HOLES. REPAIRED PER EA 5310-01555 AND BOEING TELEX ASA-SEA-97-0432. (M)SDR UPS97224851Floorbeam · corrodedINSPECTION TYPE-SI, CORROSION UPPER FLANGE OF FLOORBEAM BS 312 WL 208 LBL 27. REMOVED DAMAGED SECTION OF FLOORBEAM AND REPLACED PER SRM 53-10-8.SDR AALA972080Floorbeam · corrodedTUL - FRAME 33 CORRODED BETWEEN TRACK 2 AND 3. REPAIRED FLOOR CROSSBEAM IAW ESO DATED 29 OCT 97. (M)SDR AALA972057Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM CAP ON BOTH SIDES OF ROLLER TRAY AT FRAME 27. SPLICED NEW SECTION OF FLOOR CAP. (M)SDR 97FDEA00794Floorbeam · corrodedCORROSION (C53-221-01) ON UPPER SURFACE OF FLOOR SUPPORT AT BS 264, WL 208, LBL 2 THROUGH LBL 7. *S/D* REMOVED AND REPLACED UPPER CHORD OF FLOORBEAM (25G BEAM) DUE TO CORROSION BEING OUT OF LIMITS IAW FED SRM 53-10-1, 51-30-2, 51-30-2 AND BAC DRAWING 65-1758SDR UPS97825288Floorbeam · corrodedINSPECTION TYPE-C/CK, FUSELAGE STATION 1660 FLOORBEAM IS CORRODED. REMOVED CORRODED SECTION OF BEAM IAW REO 03846, FABBED REPAIR ANGLE IAW REO 03846. INSTALLED, ALODINED AND PRIMED IAW REO 03846 AND DC8 SRM 51-3-0 AND 51-1-20D AND 51-1-8.SDR UPS97825260Floorbeam · corrodedINSPECTION TYPE:C/CK, FS 1660 FLOORBEAM IS CORRODED. REMOVED CORRODED SECTION OF BEAM IAW REO 03846. FABBED REPAIR ANGLE IAW REO 03846 INSTALLED ALODINED AND PRIMED IAW REO 03846 DC8 SRM 51-3-0 AND 51-1-20D AND 51-1-8.SDR UPS97225128Floorbeam · corrodedINSPECTION TYPE-D, CORROSION ON ANCHOR CLIP HOLE ON UPPER AND LOWER SURFACE OF FLOORBEAM TOP CHORD BS 312 LBL 19. REPAIR CARRIED OUT IAW SRM 53-10-8 FIG 7.SDR SWAA970963Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORROSION AT BS 328 AND FROM 727 TO 947. REPAIRED PER BOEING SRM.SDR AALA972033Floorbeam · corrodedTUL - FOUND CORROSION TOP AND BOTTOM OF FORWARD UPPER CHORD OF STATION 344 FLOORBEAM FROM LBL 12 INCHES - RBL 12 INCHES. REMOVED CORROSION, INSTALLED REPAIR PER SRM 53-10-8 FIG 7 AND ESO 11697, DATED 10-6-97. (M)SDR 97FDEA00784Floorbeam · corrodedNR 0253 009 CORROSION (C53-224-06) ON FLOORBEAM BS 344, RBL 15-LBL 60, WL 208. UPPER CHORD OF 344 FLOORBEAM, RBL 65 TO LBL 65, WL 208 WAS FOUND TO BE OUT OF LIMITS. REMOVED CORRODED UPPER CHORD FROM RBL 65 TO LBL 65 AND INSTALLED NEW UPPER CHORD PER FED-EX DSDR SIMA973001Floorbeam · corrodedSAW - DURING CPCP-4 INSPECTION MAINTENANCE DISCOVERED FLOORBEAM 36 CORRODEDOUT OF LIMITS. MAINTENANCE REMOVED AND REPLACED FLOORBEAM 36 IAW SRM 51-25-02 AND 51-25-03. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR 97FDEA00777Floorbeam · corrodedNR 0103 008 CORROSION (C53-224-06) ON FLOORBEAM BS 328, LBL 37, WL 208. REMOVED CORROSION (C53-224-06) FOUND TO BE OUT OF LIMITS. REPAIRED BS 328, LBL 37, WL 208 PER FED-EX EA NR 7-5310-36824.SDR MWEA97809Floorbeam · misdrilledDURING C-CHECK, FOUND A HALF DRILLED HOLE IN RADIUS OF COCKPIT FLOORBEAM STATION 160. MTC REPAIRED IAW SRM 53-01 FIGURE NR 1 AND FIGURE NR 2.SDR UPS97225066Floorbeam · corrodedINSPECTION TYPE-D, CORROSION AT STA 312 FLOORBEAM TOP CHORD ANCHOR NUT HOLE LBL 2. REPAIR CARRIED OUT IAW SRM 53-10-8 FIG 7.SDR 97FDEA00773Floorbeam · corrodedCORROSION (C53-111-01, 2) UNDER NUT PLATES ON FLOORBEAM BS 600, RBL 25 LBL 25, WL 200 FWD CARGO BAY. *S/D* MECHANICALLY REMOVED CORROSION FROM UNDER NUT PLATES ON BS 600 FLOORBEAM, RBL 25 TO LBL 25, WL 200 FWD BAY. FOUND TO BE OUT OF LIMITS PER FED SRM 53-1SDR UPS97224763Floorbeam · corrodedINSPECTION TYPE:SI CORROSION ON UPPER FLANGE OF FLOORBEAM BS 344 WL 208 RBL 10. REPAIRED FLOOR BEAM IAW SRM 53-10-8. REPLACED DEMAGED SECTION OF UPPER CHORD.SDR SIMA972951Floorbeam · corrodedDURING CPCP-4 INSPECTION MAINTENANCE DISCOVERED FLOORBEAM 38 CORRODED OUT OF LIMITS. MAINTENANCE REMOVED AND REPLACED FLOORBEAM 38 IAW SRM 51-25-00. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR CALA9701497Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT BS 294 ON RT SIDE. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED. A NEW SECTION AND DOUBLERS WERE FABRICATED AND INSTALLED IAW SRM 53-10-51.SDR AALA974061Floorbeam · corrodedAFW - FLOORBEAM AT STATION 1640 HAS CORROSION REMOVAL BEYOND LIMITS. REF MRB 757-1251. REFINISHED THE AREA PER REF C SRM SECTION. (M)SDR UPS97524751Floorbeam · corrodedINSPECTION TYPE:C MAIN DECK FLOORBEAM UPPER CHORD HAS AREAS OF CORROSION ON UPPER SURFACE BETWEEN BS 990-BS1070 LBL 45 WL 208. CORROSION REWORK OUT OF LIMITS IAW SRM 53-00-51. REPAIRED FLOORBEAM STA 990-1070 LBL 45 WL 208 IAW BF GOODRICH AEROSPACE EWO97-4086SDR DL73K972122Floorbeam · crackedTHE FLOORBEAM AT BS 520 WAS FOUND CRACKED AT RBL 25. CRACKING FOUND IS TYPICAL OF THAT DESCRIBED IN SB 737-53-1120 (R1). REPAIR PER SB 737-53-1120 AUTHORIZED BY DELTA ER/A 330883-14.
Back to JASC 5315