What was found
INSPECTION TYPE-C/CK, FUSELAGE STATION 1660 FLOORBEAM IS CORRODED. REMOVED CORRODED SECTION OF BEAM IAW REO 03846, FABBED REPAIR ANGLE IAW REO 03846. INSTALLED, ALODINED AND PRIMED IAW REO 03846 AND DC8 SRM 51-3-0 AND 51-1-20D AND 51-1-8.