JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202307120612Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM EXISTING REPAIR FILLER AT BS 987 AT RBL 45. REPAIRED FLOOR BEAM PER SRM 53-70-51 AND SRM 51-40-02.SDR AALA202307129172Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM EXISTING REPAIR FILLER AT BS 987 AT RBL 35. REPAIRED FLOOR BEAM PER SRM 53-70-51 AND SRM 51-40-02.SDR SWAA2023082975871Floorbeam · crackedCRACKED FLOOR BEAM AT FWD CABIN BS328 RBL20 WL208.<[01] VERIFIED APPLICABILITY PER SRM 53-10-51-1A-1;[02] REMOVED DAMAGE ON FLOOR BEAM AT FWD CABIN BS328 RBL20 WL208. 1.1'L X 0.950' W DAMAGE EXCEED ALLOWABALE LIMITS GIVEN ON SRM 53-10-51-1A-1 PAR 4.C(1) SUBMITSDR SWAA2023082975855Floorbeam · corrodedCORROSION ON BS 986 PREVIOUS REPAIR UPPER FWD FLANGE AT FLOORBOARD HOLES RBL 39 & RBL 42 WL 208<[01] NO ALLOWABLE LIMITS FOUND ON SRM FOR PREVIOUS REPAIR DAMAGE REPAIR PARTS TO BE REMOVED AND BS986 TO BE REPAIRED I.A.W SRM 53-70-51-2R-4 REPAIR. 4 ALTERNATIVE 1SDR SWAA2023082975856Floorbeam · corrodedCORROSION ON BS 986 UPPER CHORD FWD FLANGE AT FLOORBOARD HOLES LBL 38; LBL 41; LBL 44 & LBL 46 WL 208<[01] VERIFIED APPLICABILITTY SRM PER SRM 53-70-51-1A-1;[02] EVALUATED CORROSION ON BS 986 UPPER CHORD FWD FLANGE AT FLOORBOARD HOLES LBL 38 1'X1'X0.020'; LBL SDR SWAA2023081575970Floorbeam · corrodedCORROSION ON BS 328 FLOOR BEAM RBL 42 WL 208.<[01] ADDED ELEMENT P/N TO MEASUREMENT TABLE;[02] VERIFIED SRM APPLICABILITY OF SRM 53-10-51-2R-7.;[03] UPDATED/CORRECTED STEP 1;[04] ACCOMPLISHED HFEC SURFACE SCAN OF CUT EDGE IAW 737 NDTM PART 6 CHAPTER 51-00-00 PSDR SWAA2023081575850Floorbeam · corrodedCORROSION ON BS 986 FLOOR BEAM UPPER FLANGE RBL 40-44 AND LBL 44 WL 208.<[01] UPDATED STEPS 1-10.;[02] PARTIAL STEP 11-13;[03] VERIFIED THE APPLICABILITY OF SRM 53-70-51-1A-1;[04] EVALUATED CORROSION ON BS 986 UPPER FWD FLANGE AT LBL 44; AREA 1'X1.2'X0.036'; ASDR SWAA2023080976090Floorbeam · corrodedCORROSION ON FLOOR BEAM AT AFT CABIN BS986 LBL43 WL208.<[01] VERIFIED SRM 53-70-51-1A-1 IS APPLICABLE FOR ALLOWABLE DAMAGE TO SECT. 47 FLOOR STRUCTURE.;[02] CONCUR WITH APPLICABILITY OF SRM 53-70-51-1A-1.;[03] REMOVED CORROSION FROM UPPER FLANGE OF BS 986.5 FLSDR DALA2023070605441Unknown · unknownSHIP 3353 CORROSION FLOOR BEAM YA FR72 TO FR73 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM YA LOC. BTW FR72 TO FR73 AT AFT GALLEY AREA. (2850994)SDR DALA2023070605474Unknown · unknownSHIP 0676 SECONDARY NRC: CORROSION ON CPAX FLOOR BEAM STA 1640 BTW LBL 60 TO BL0 IN REF NRC 00481. CORRECTIVE ACTION: REPAIRED PER B757-200 SRM-53-00-51. (2849448)SDR CALA2023070502169Floorbeam · corrodedFOUND FLOOR BEAM CORROSION AT STA303 ,LBL 52 IN CABIN REPAIRED THE FLOOR BEAM AS PER UAL EC/RA 5310-08174,DETAIL REF T O UAL 44-0008 FORM ATTACHED, WORK ACCOMPLISHED BY V928158 DETAIL STEPS REF TO BSH NR N0473, WORK ACCOMPLISHED BY INSP V928 158 RII INSPECTIONSDR CALA2023070502168Floorbeam · corrodedFOUND FLOOR BEAM CORROSION AT STA325 ,LBL 30-52 IN CABIN REPAIRED THE FLOOR BEAM AS PER UAL EC/RA 5310-08175,DETAIL REF T O UAL 44-0008 FORM ATTACHED, WORK ACCOMPLISHED BY V928158 DETAIL STEPS REF TO BSH NR N0474, WORK ACCOMPLISHED BY INSP V928 158 RII INSPECTSDR DALA2023070405362Unknown · unknownSHIP 3355 CORROSION ON FLOOR BEAM -Y1552.5 LOCATED FR31 TO FR37 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1552.5 LOC BETWEEN FR31 TO FR37 IN PASSENGER CABIN. (2846596)SDR DALA2023070405361Unknown · unknownSHIP 3355 CORROSION ON FLOOR BEAM Y1456 LOCATED FR26 TO FR37.4 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM Y1456 LOCATED FR26 TO FR37.4 IN PASSENGER CABIN. (2846541)SDR SWAA2023080474160Floorbeam · corrodedCORROSION ON FLOOR BEAM 986.5 RBL 43 WL 208.1 AT AFT GALLEY AREA 2023-422400<[01] TOOL USED: THICKNESS GAGE. P/N: 45MG; S/N: 130060401; DUE DATE: 20-MAR-24.;[02] TOOL USED: EDDY CURRENT EQUIPMENT. P/N: NORTEC 600D. S/N: 220273012. DUE DATE: 17-DEC-23.;[03] REPSDR VNAA202308040010Floorbeam · crackedCRACK ON CENTER COCKPIT FLOOR BEAM RBL12 AT FS 280.00 FLOOR INTERNAL SUPPORT STRUCTURE BELOW FLIGHT COMPARTMENT WAS FOUND. CENTER COCKPIT FLOOR BEAM RBL12 AT FS 280.00 FLOOR INTERNAL SUPPORT STRUCTURE WAS REPAIRED PER REO 690-53-11-1576 REV. --SDR SWAA2023073174200Strap · corrodedCORROSION FOUND AT STA.947 LBL25 UPPER AFT FLANGE AT FLOOR BEAM<[01] REMOVED DAMAGE PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1.;[02] ADDED TOOLS.;[03] VERIFIED 1. WILSON WHITT (TECHNICIAN); 02-JUL-2023 17:27 UTC<BR>REMOVED DAMAGE PER SRMSDR SWAA2023073174201Strap · corrodedIN THE AFT CABIN WET AREA THERE IS EVIDENCE OF CORROSION ON TOP OF THE FLOOR BEAM AT STATION 947; LBL 16.<[01] REMOVED DAMAGE PER SRM 51-10-02. FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1.;[02] ADDED TOOLS;[03] VERIFIED 1. WILSON WHITT (TECHNICIAN); 02-JULSDR DALA2023070305357Unknown · unknownSHIP 3123 AFTER REMOVED FLOOR BEAM Y1192 PERFORMED VISUAL INSPECTION ON AREA AND FOUND ELONGATED HOLES (4 E/A) ON CROSSBEAM LOC. AT FR68 AT LEVEL Y119 2 AT AFT GALLEY AREA. CORRECTIVE ACTION: COMPLIED WITH ER/A 609536-14. (2845768)SDR DALA2023070305347Unknown · unknownSHIP 3118 CORROSION FLOOR BEAM -Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y1162.5 LOCATED BTW FR 68 TO FR 69 AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 AND SRM 51-42-11. (2844300)SDR SWAA2023073173538Floorbeam · crackedCABIN FLOOR STRUCTURE BREAK ASSY CRACKED STA 540 AT BL 0 TO RBL 24.<[01] REMOVED; AND REPLACED BREAK ASSY. REF. SRM. 51-40-02.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1.SDR SWAA2023073173540Floorbeam · crackedCABIN FLOOR STRUCTURE BREAK ASSY CRACKED STA 540 AT BL 0 TO LBL 24.<[01] REMOVED; AND REPLACED BREAK ASSY. REF. SRM. 51-40-02.;[02] INSPECTION VERIFIED CORRECTIVE ACTION STEP 1.SDR AALA202307039812Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM AT BS 986.5 AND LBL 44. REPAIRED FLOOR BEAM PER SRM 53-70-51.SDR CALA2023070302130Floorbeam · corrodedAFT CABIN FLOOR BEAM Y-765 HAS CORROSION FR64 TO FR66. REMOVED CORROSION ON AFT CABIN BEAM Y-765 FR64 TO FR66 L=1.3" W= 1.0" D=0.91" FOUND TO BE OUT OF LIMITS IAW SRM 51-41-15 REMOVED AND REPLACED BEAM Y-765 IAW SRM 51-42-11. EMP: V934143 WC: 58844 STA: ST ENGSDR AALA202306306619Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FLOOR BEAM UPPER T CHORD. LOCATED AT BS 986.5 FROM LBL 32.0 TO RBL 32.0. REPAIRED T CHORD PER SRM 53-70-51-2 PROCEDURE 4 TABLE 201.SDR CALA2023063002104Floorbeam · corrodedAFT CABIN FLOOR BEAM Y-765 HAS CORROSION FR64 TO FR66. REMOVED CORROSION ON AFT CABIN BEAM Y-765 FR64 TO FR66 L=1.3" W= 1.0" D=0.91" FOUND TO BE OUT OF LIMITS IAW SRM 51-41-15 REMOVED AND REPLACED BEAM Y-765 IAW SRM 51-42-11. EMP: V934143 WC: 58844 STA: ST ENGSDR SWI2023F00232Unknown · crackedRH COCKPIT FLOOR BEAM AT APPROX RBL12, FWD SIDE OF FS280 FOUND TO BE CRACKED (C-CHECK RO 8/16/2023) REMOVED CRACKED BEAM AND REPAIRED RH COCKPIT FLOOR BEAM AT APPROX RBL12, FWD SIDE OF FS280 REF CRJ700 SRM 53-11-43-201-003-A01. COMPLIED WITH TASK CARD SDR SWI2023F00217Unknown · crackedRH COCKPIT FLOOR BEAM AT APPROX RBL12, FWD SIDE OF FS280 FOUND TO BE CRACKED (C-CHECK RO 8/16/2023) REMOVED CRACKED BEAM AND REPAIRED RH COCKPIT FLOOR BEAM AT APPROX RBL12, FWD SIDE OF FS280 REF CRJ700 SRM 53-11-43-201-003-A01. COMPLIED WITH TASK CARD SDR SWI2023F00216Unknown · crackedLH COCKPIT FLOOR BEAM AT APPROX LBL12, FWD SIDE OF FS280 FOUND TO BE CRACKED (C-CHECK RO 8/16/2023) REMOVED AND INSTALLED NEW COCKPIT FLOORBEAM AND ALL REPAIRED PARTS (TYPE IV) AT LBL 12 FS265 - FS280 REF CRJ700 SRM 53-11-43-201-003-A01 REV 38 JUL 25/2SDR AALA202307197503Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM BETWEEN FR 66 AND FR 68, BETWEEN Y1292 AND Y1162. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR AALA202307140778Unknown · unknownAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR BEAM LOCATED AT BS 987.5, S17L, AND LBL 61. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R PROCEDURE 6 ALTERNATIVE 3.SDR AALA202307144164Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON PASSENGER CABIN FLOOR BEAM, AROUND FASTENER HOLE, LOCATED AT 986.5, S17R, AND RBL 61. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-6.SDR CALA2023062802078Floorbeam · corrodedFLOOR BEAM Y765 UPPER SURFACE HAS SEVERAL SPOTS WITH CORROSION FR66 TO FR68 DOT 41-20SDR FDEA202306251213Floorbeam · damagedFWD CARGO PIT FLOOR BEAM AT APPROX STA 6-10 CENTER BUTTLINE HAS AN IMPACT DAMAGE IN WHICH THE VERTICAL LEG WAS DEFORMED BEYOND ALLOWABLE LIMITS. REPAIRED FLOOR BEAM PER SRM 53-00-00-0G FIG 208 MAJOR REPAIRSDR SWAA2023072871354Floorbeam · corrodedAFT GALLEY FLOOR STRUCTURE STA. 947.5 LBL 25 HAS CORROSION ON FLOOR BEAM.<[01] REMOVED CORROSION PER SRM 51-10-02. BLENDED AREA OUT OF LIMITS PER SRM 53-70-51-1A-1. REMANING THICKNESS IS .084?.[10] FABRICATED ALL REPAIR PARTS I.A.W SRM 53-70-51-2R-5;[11] VERIFSDR ASAA2023062344133Floorbeam · corrodedFLOOR SUPPORT AT FS 986.5 HAS AREAS OF CORROSION FROM BL0 TO RBL 30. GROUNDED - YES. BLENDED CORROSION, FOUND TO BE OUT OF LIMITS IAW B737-900 SRM 53-70-51-1A-1. REPAIRED FLOOR SUPPORT (BEAM) IAW B737-900 SRM 53-70-51-2R-4. W= 1.0" O= .150 R= .113 L= 4.00" D= SDR REXA2022071700503Floorbeam · corrodedFS280 CROSSBEAM IS CORRODED FROM BL0 TO RBL12 INSTALLED NEW SERVICEABLE R/H F.S. 280 CROSSBEAM P/N CC670-34094JP-2S IAW CRJ-900 SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01, 51-42-21-001-001-A01 AND 51-42-22-001-001-A01.SDR CALA2023062301984Floorbeam · corroded(B737-53-3-0737) M/C STA 946 LBL 53 FLOOR BEAM HAS CORROSIONSDR SWAA2023071970379Floorbeam · corrodedCORROSION ON FLOOR BEAM UPPER FLANGE BS 947 LBL 25 AND LBL 50 WL 208.<[01] VERIFIED APPLICABILITY OF SRM 53-70-51-1A-1 ALLOWABLE DAMAGE [12] CORRECTION ACTION: FABRICATED REPAIR PARTS ITEM(1) T-CHORD 2EA FROM BAC1505-101045 7075T6 LOT #1522472-1; ITEM(2) ANGLESDR SWAA2023071970381Floorbeam · corrodedCORROSION ON FLOOR BEAM BS 947 RBL 50 WL 208.<[01] VERIFIED APPLICABILITY OF SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1;[02] EVALUATED CORROSION ON BS 947 FLOORBEAM UPPER FLANGE AT RBL 50 WL 208 IN AN AREA OF .8' X .6' LOWEST REMAINING MATERIAL THICKNESS .125; CORROSDR GCXA2023FA0000323Floorbeam · corrodedMAIN CABIN FLOOR SUPPORT BEAM Y254 BETWEEN C16-C19 LBL10" HAS CORROSION BEYOND REPAIR LIMITS/ REPLACEDSDR SWIA2023070300619Unknown · corrodedCORROSION, AFT WET AREA, ON LH LONGITUDINAL FLOOR BEAM AT FRAME 87 WHERE THE BEAM PASSES BETWEEN THE LH AND CENTER SHEAR PANELS. (C-CHECK RO 6/30/2023) REMOVED AND REPLACED LH LONGITUDINAL FLOOR BEAM AT FRAME 87 WHERE THE BEAM PASSES BETWEEN THE LH ANDSDR CALA2023062802042Floorbeam · corroded(B737-53-3-0737) M/C STA 946 LBL 53 FLOOR BEAM HAS CORROSION 43 OP 32036 BY MECH V943916 INSP AQC029. REPAIRED FLOOR BEAM AT STA 946 LBL 53 REF B737-700 SRM 53-70-51- 2R-5 REPAIR 5. DATA WAS TRANSCRIBED FROM PAPER DOC AERSALE WO 39SDR CALA2023062802041Floorbeam · corrodedB737-53-3-0737 AFT CABIN FLOOR BEAM AT BS986.5 L/H AND R/H 6" FROM BL O HAS CORROSION AND LBL46 R-4 AT BS 985.5. DATA WAS TRANSCRIBED FROM PAPER DOC AERSALE WO 3943 OP 31836 BY MECH V943919 INSP AQC050. REMOVED AND DISCARDED EXISTING REPAIR FABRICATED AND INSTSDR DALA2023062005012Unknown · unknownCORROSION FLOOR BEAM -Y765 LOCATED BTW FR 66 TO FR 70 AT AFT GALLEY AREA. REPLACED FLOOR BEAM -Y765 LOCATED BTW FR 66 TO FR 70 AT AFT GALLEY AREA (SSI 534147) AS PER SRM A321. 51-72-11 AND DRAWING 53472001 RELEASE DATE 07 DEC. (LP#2824265)SDR SCNA20240310107Floorbeam · crackedDEFECT WO 74296 NR00075: CRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO LBL 2 4.75 AT PASSENGER CABIN - - RESOLUTION: REPLACED PLATE ON INTERCOSTAL LOCATED ON FLOOR STRUCTURE BS 540 BTW BL 0 TO LBL 24.75 AT PASSENGER CABIN IAW B737-800 SRSDR ABXA20230626136Floorbeam · corrodedDURING N317CM C-CHECK AT AIRBORNE (TAMPA), FWD CARGO COMP FLOOR BEAM UPPER CAP EXFOLIATED AT STA 701 LBL 48. REMOVED CORROSION IAW B767-300 SRM 51-00-02 ORIGINAL THICKNESS .100 REMOVED .030 REMAINING THICKNESS .070 TO BR OUT OF LIMITS IAW B767-300 SRM 53-00-07SDR CALA2023061901901Floorbeam · corrodedA3NB-53-3-6038 MAIN CABIN FLOOR BEAM 7254-765 HAS CORROSION AT F R16SDR CALA2023061901900Floorbeam · corrodedAA3NB-53-6038 MAIN CABIN LF FLOOR BEAM Y254 CORRODED AT FR 16SDR AALA202307184844Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM BETWEEN FR 64 AND FR 66 AT +Y1292. REPLACED FLOOR BEAM PER SRM 51-42-11.
Back to JASC 5315