JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2020012600221Fitting · crackedSHEAR FITTING AT BS 540, LBL 15.04 WAS CRACKED. REMOVED AND REPLACED THE SHEAR FITTING IAW SRM 51-40-02, AND DWG 111A2000.SDR CALA2020012600220Fitting · crackedSHEAR FITTING AT BS 540, LBL 40.87 WAS CRACKED. REMOVED AND REPLACED THE SHEAR FITTING IAW SRM 51-40-02, AND ECRA 5714-01044.SDR CALA2020012600219Fitting · crackedSHEAR FITTING AT BS 540, RBL 6.14 WAS CRACKED. REMOVED AND REPLACED THE SHEAR FITTING IAW SRM 51-40-02, AND DWG 111A2000.SDR DALA2020012310530Plate · corrodedCORROSION ON RT SIDE PLATE FROM BS 1440 TO 1530 IN THE AFT CARGO BAY. REPLACED IAW SRM 51-40-02-0G, PAR. 4, 7, AND DWG 146N5391, REV. B.SDR DALA2020012390527Plate · corrodedCORROSION ON LH SIDE PLATE FROM BS 1410 - 1530 IN THE AFT CARGO BAY. REPLACED IAW SRM 51-40-02-0G, PAR.7, AND DWG 146N5391 REV. B.SDR DALA2020012390526Floor Support · corrodedCORROSION ON FLOOR SUPPORT BS 1500 TO 1520, LBL 7.55 IN THE AFT CARGO BAY. REPAIRED IAW SRM 53-00-53-2R REPAIR 1.SDR FDEA2020012190172Floor Support · crackedFWD CARGO BELOW THE FLOOR LEVEL AT FRAME 38.1 APPROX RBL56 STRUCTURAL INTERCOSTAL IS CRACKED AND CORRODED AT THE SAME LOCATION REMOVED AND REPLACED NEW INTERCOSTAL IAW A300-600 SRM 51-40-21 AND SRM 51-40-44SDR FDEA2020012190171Brace · crackedFWD CARGO COMPARTMENT R/H SIDE JUST BELOW THE MAIN CABIN FLOOR LEVEL AT APPROX RBL105 BETWEEN FRAMES 38.1 AND 38.2 SUB-STRUCTURAL BRACE IS CRACKED . FABRICATED NEW SUPPORT PER DWG A53781038 ISSUE G, REMOVED AND REPLACED SUPPORT PER DWG A53781962 ISSUE ESDR FDEA2020012190170Brace · crackedFWD CARGO COMPARTMENT L/H SIDE JUST BELOW THE MAIN CABIN FLOOR LEVEL AT APPROX LBL105 BETWEEN FRAMES 38.1 AND 38.2 SUB STRUCTURAL BRACE IS CRACKED FABRICATED NEW SUPPORT PER DWG A53781038 ISSUE G, REMOVED AND REPLACED SUPPORT PER DWG A53781962 ISSUE ESDR FDEA2020012190169Web · corrodedFLOOR SUPPORT STRUCTURE UNDER LAV CORRODED @ LBL30 BETWEEN FRAMES 11-14 FABRICATED NEW WEB PER AIRBUS DWG A53612214 ISSUE N, REMOVED AND REPLACED WEB AND SUPPORT PER SRM 51-40-21 AND DWG A53612214 ISSUE N.SDR FDEA2020012190168Brace · crackedFWD CARGO COMPARTMENT R/H SIDE JUST BELOW THE MAIN CABIN FLOOR LEVEL AT APPROX RBL105 BETWEEN FRAMES 38 AND 38.1 SUB-STRUCTURAL BRACE IS CRACKED (STREAMER ATTACHED) FABRICATED NEW SUPPORT PER AIRBUS DWG A53781038 ISSUE G, REMOVED AND REPLACED SUPPORT PESDR CALA2020012300204Fitting · crackedSHEAR FITTING AT BS 540 RBL 15.04 WAS CRACKED. REMOVED AND REPLACED THE SHEAR FITTING IAW SRM 51-40-02, AND EC / RA 57-14-01044.SDR SWAA2021062923415Scuff Plate · crackedR1 DOOR SCUFF PLATE HAS 2 EACH CRACKS AT BEND RADIUS. / RECEIVED NEW SCUFF PLATE FOR R1 DOOR; SCUFF PLATE WILL BE INSTALLED ON WORK CARD #J725-025-00-01Y 2015609 2000/0002.SDR SWIA2020030549077Structure · corroded* CORROSION DETECTED ON "BOTH" FWD/AFT SIDES OF F.S. 549.00, L/H FUSELAGE, BELOW FLOOR SILL AND ABOVE FBB DOOR SURROUND STRUCTURE (MARKED). (C-CHECK) RO 3/3/2020 COMPLIED WITH ALL STEPS OF REO. SEE CONTINUE CARD FOR DETAILS. NO LEAKS NOTED.SDR SWIA2020030549076Structure · corroded* CORROSION DETECTED ON "BOTH" FWD/AFT SIDES OF F.S. 533.00, L/H FUSELAGE, BELOW FLOOR SILL AND ABOVE FBB DOOR SURROUND STRUCTURE (MARKED) (C-CHECK) RO 3/3/2020 COMPLIED WITH ALL STEPS OF REO. SEE CONTINUE CARD FOR DETAILS.SDR AALA2020021109027Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN WET AREA FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR PLATE PER SRM 51-72-11.SDR AALA2020021109026Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN WET AREA FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-72-11.SDR SWIA2020020548223Floor Support · corrodedCORROSION IN R/H FLOOR BOARD SUPPORT FR.87. (C-CHECK) RO 2/03/2020 REMOVED AND REPLACED R/H FLOOR BOARD SUPPORT FR 87. REF SRM. / RESTORED SURFACE PROTECTION ON R/H FLOOR BOARD SUPPORT FR 87. REF SRM. PO# 245304, 23781. / APPLIED CIC TO R/H FLOOR BOARD SUSDR SWAA2020020541009Web · corrodedFORWARD CARGO BAY SUB THRESHOLD WEB CORRODED BETWEEN BS. 440 TO BS. 500, RBL 23. / R&R WEB FROM STA440- STA 500 WL156 88415U 24JAN20.SDR IPXA2020020315646Stiffener · crackedINSPECTION TYPE:C12CRACK ON CENTER WING TANK STIFFENER (P/N : 111T2011-5) ON STA 785.9 , LBL 55REPAIR I.A.W 767-300F SRM 57-10-10-2R-2 REPAIR 2 REV.76.01 , UPS EO B767-5740-58151-B , BOEING SRID : 3-4620819146 AND UPS EO B767-5710-75257-ASDR IPXA2020020315645Stiffener · crackedINSPECTION TYPE:C12CRACK ON CENTER WING TANK STIFFENER (P/N : 111T2005-8) ON STA 785.9 , RBL 11REPAIR I.A.W 767-300F SRM 57-10-10-2R-2 REPAIR 2 REV.76.01 , UPS EO B767-5740-58151-B , BOEING SRID : 3-4620819146 AND UPS EO B767-5710-75257-ASDR IPXA2020020315644Stiffener · crackedINSPECTION TYPE:C12CRACK ON CENTER WING TANK STIFFENER (P/N : 111T2008-12) ON STA 785.9 , RBL 33REPAIR I.A.W 767-300F SRM 57-10-10-2R-2 REPAIR 2 REV.76.01 UPS EO B767-5740-58151-B , BOEING SRID : 3-4620819146 AND UPS EO B767-5710-75257-ASDR IPXA2020020315643Stiffener · crackedINSPECTION TYPE:C12CRACK ON CENTER WING TANK STIFFENER (P/N : 111T2008-11) ON STA 785.9 , LBL 33REPAIR I.AW 767-300F SRM 57-10-10-2R-2 REPAIR 2 REV.76.01 , UPS EO B77-5740-58151-B , BOEING SRID : 3-4620819146 AND UPS EO B767-5710-75257-ASDR IPXA2020020315641Stiffener · crackedINSPECTION TYPE:C12CRACK ON CENTER WING TANK STIFFENER (P/N : 111T2011-6) ON STA 785.9 , RBL 55REPAIR I.A.W 767-300F SRM 57-10-10-2R-2 REPAIR 2 REV.76.01 , UPS EO B767-5740-58151-B , BOEING SRID : 3-4620819146 AND UPS EO B767-5710-75257-ASDR REXA2020012880124Stringer · corroded"[ IN REFERENCE NRC 00211 ]: INITIAL INSPECTION: CORROSION ON STRINGER25RH IN STA. FS= 280 TO FS= 327 AT MAIN AVIONICS COMPARTMENT. (E/E) [TASK 900-53-140-300 APPENDIX A ] TCI: 100-09, 100-09E4, 100-09E5
""CORROSION LEVEL 2, STRINGER 25RH STA 280 TO 327SDR DALA2020012219511Floor Support · corrodedCORROSION WAS FOUND ON THE FLOOR SUPPORT, BS 1320 - 1340, LBL 10.45 IN THE AFT CARGO BAY. THE FLOOR SUPPORT WAS REPAIRED IAW SRM.SDR DALA2020012280509Angle · corrodedCORROSION FOUND ON THE ANGLE BETWEEN BS 720 - 740, LBL 61, IN THE PAX CABIN FLOOR STRUCTURE. REMOVED CORROSION IAW SRM, INSPECTED AND FOUND TO BE OUT OF LIMITS. ANGLE WAS REPLACED IAW SRM.SDR AALA202001221906Stiffener · crackedAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND WHEEL WELL FORWARD BULKHEAD, VERTICAL STIFFNER , LOWER ATTACH BRACKET IS CRACKED. REPLACED BRACKET PER SRM 51-40-08.SDR DALA2020012190452Floor Support · corrodedCORROSION FOUND ON THE FLOOR SUPPORT, BS 1645 - 1680, BL 0 IN THE PAX CABIN. THE CORROSION WAS REMOVED AND EVALUATED BEING OUT OF LIMITS. THE TWO FLOOR SUPPORTS WERE REPLACED IAW SRM.SDR DALA2020012190451Floor Support · corrodedCORROSION FOUND ON FLOOR SUPPORT FROM BS 1320 TO 1340, RBL 2.90 IN THE AFT CARGO BAY. THE FLOOR SUPPORT WAS REPAIRED IAW SRM.SDR SWAA2021082227767Floor Support · corrodedINTERCOSTAL BETWEEN FRAME STA 747 TO STA 767 @ APPROX RBL 25 HAS COROSSION ON BOTTOM SURFACE IN AFT CARGO COMP. / REMOVED AND REPLACED INTERCOSTAL BETWEEN STA 747 TO 767 @ RBL 25 IN AFT LOWER CARGO. P/N 146A7505-2 PER SRM 51-40-05 AND SRM 51-40-02. ( SA-M 326 SDR SWAA2021062925016Scuff Plate · crackedCRACK FWD CORNER SCUFF PLATE AT FWD CARGO COMPARTMENT / PERFORMED PERMANENT REPAIR ON FWD CORNER SCUFF PLATE LOC; AT FWD CARGO COMPARTMENT IAW EA NO.1-A53-2076 REV.11.SDR SWAA2021062425018Scuff Plate · crackedCRACK CENTER SCUFF PLATE AT FWD CARGO COMPARTMENT / PERFORMED PERMANENT REPAIR ON CENTER SCUFF PLATE LOC; AT FWD CARGO COMPARTMENT IAW EA NO.1-A53-2076 REV 11.SDR SWIA2020031049098Intercostal · cracked* THE INTERCOSTAL BETWEEN FS 621 AND FS 625, AT STRINGER LOCATION 15R, HAS A SUSPECTED CRACK ON ITS OUTBOARD FLANGE THAT ATTACHES TO THE FUSELAGE SKIN. (C CHECK) RO 3/7/2020 REMOVED CRACKED INTERCOSTAL CLIP REF. CRJ200 SRM. LOCATED AND DRILLED FULL SIZE ALSDR SWIA2020031049097Intercostal · cracked* THE INTERCOSTAL BETWEEN FS 621 AND FS 625, AT STRINGER LOCATION 14L, HAS A SUSPECTED CRACK ON ITS OUTBOARD FLANGE THAT ATTACHES TO THE FUSELAGE SKIN. (C CHECK) RO 3/7/2020 VERIFIED THE CRACK. REMOVED THE CRACKED INTERCOSTAL / BRACKET AT STRINGER 14L BETSDR SWIA2020031049096Intercostal · cracked* THE INTERCOSTAL ADJACENT TO STRINGER 14R, THAT SPANS BETWEEN FS 621 AND FS 625, IS CRACKED. (C CHECK) RO 3/7/2020 REMOVED AND REPLACED CLIP P/N: 601-35012-52 BETWEEN FS 621 AND FS 625, STRINGER 14R REF. CRJ-200 SRM AND BOMBARDIER. COMPLIED WITH SKYWEST TSDR SWIA2020031049095Intercostal · cracked* THE INTERCOSTAL ADJACENT TO STRINGER 14L, THAT SPANS BETWEEN FS 621 AND FS 625, IS CRACKED. (C CHECK) RO 3/7/2020 REMOVED AND REPLACED CLIP P/N: 601-35012-51 BETWEEN FS 621 AND FS 625, STRINGER 14L REF. CRJ-200 SRM AND BOMBARDIER. COMPLIED WITH SKYWEST TSDR SWIA2020030549075Angle · corroded* CORROSION DETECTED AT STGR (19R) ON (CLIP/ANGLE) MEMBER THAT ATTACHES TO STGR (19R) ON AFT SIDE OF F.S. 661.00+90.00 (MARKED). (C-CHECK) RO 3/3/2020 REMOVED TENSION FITTING P/N SH670-39090-1 REF CRJ900 SRM; LOCATED, DRILLED AND TRIMMED REPLACEMENT DIAPHSDR SWIA2020030549073Door Sill · corroded* CORROSION DETECTED ON R/H FLOOR "SILL" FROM F.S. 349.00 TO F.S.364.00, LARGE AREAS (MARKED). (C-CHECK) RO 3/3/2020 REMOVED AND REPLACED FLOOR SILL ON RHS BETWEEN FS349-FS409 REF CRJ900 SRM. NO LEAKS NOTED AT THIS TIMESDR SWIA2020030549071Door Sill · corroded* CORROSION DETECTED ON R/H FLOOR " SILL" FROM F.S. 280.00 TO F.S. 318.70, IN SEVERAL PLACES (MARKED). (C-CHECK) RO 3/3/2020 REPLACED R/H FLOOR SILL BETWEEN FS 280.00-319.00 REF. CRJ 900 SRM NO LEAKS FOUNDSDR SWIA2020030549070Support Angle · corroded* CORROSION DETECTED ON FLOOR BOARD SUPPORT "ANGLE" ATTACHED TO FWD SIDE OF F.S. 280.00 CROSS BEAM , BETWEEN (LBL 12.0) AND (RBL 12.00) (MARKED). (C-CHECK) RO 3/3/2020 FLOOR BOARD SUPPORT ANGLE ATTACHED TO FWD SIDE OF FS280 CROOBEAM BTWN LBL12 & RBL12 REPSDR SWIA2020030348957Casting · cracked* RBL 9.0 AT FS 460 CASTING HAS CRACK AT UPPER RADIUS.(MARKED) FLOOR SUPPORT STRUCTURE. (C-CHECK) RO 2/28/2020 REMOVED AND REPLACED RBL 9.0 AT FS 460 CASTING REF DWG, AND BOMBARDIER. COMPLIED WITH SKYWEST TASK CARD. CHECKS GOOD.SDR SWIA2020021848679Intercostal · crackedINTERCOSTAL CRACKED FS 280 LBL 39 (C-CHECK) RO:2/14/2020REMOVED AND REPLACED INTERCOSTAL FS 280 LBL 39 REF CRJ 700 SRM AND COMPLIED WITH SKYCARD CL600-2C10) STRUCTURAL MAJOR REPAIR (**RII**) AND COMPLIED WITH M-337SDR FDEA2020012170162Fitting · crackedAFT CARGO COMPT SHEAR WEB STRUCTURE CLIP IS CRACKED AT O/B RBL 24.75" AND BS 1715. REMOVED, FABRICATED AND INSTALLED CLIP ON AFT CARGO COMP SHEAR WEB STRUCTURE AT O/B SIDE OF RBL 24.75, STA 1715 IAW SRM 51-40-02-OG AND B DWG 146N5329,REV - AND REV C.SDR SIMA2020013017012Web · unknownRH WEB/FLOOR AT FS 193.00 OUTBD OF THE ADG RETACTION PUMP HAS 3/8" CRACK ON THE PREVIOUS REPAIR DOUBLER. -C/A-REPLACED REPAIR DOUBLER FROM PREVIOUS REPAIR IAW SRM 53-11-43 AND ETN-CR-53-099.SDR REXA2020012870095Access Panel · cracked"HIDDEN DAMAGE :IN REF NRC S/N 00421, DURING STIFFENER REMOVAL,CRACK ON ACCESS 171CL WAS FOUND. (FUS)(SM).
"CRACK ON ACCESS 171CL WAS REPAIRED PER REO 670-53-82-430 REV --SDR C77A2020012700010Splice Plate · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-86101-001 LH UPPER SHEET, P/N 170-86101-001 RH UPPER SHEET, P/N 170-86055-001 FR84 RH SPLSDR CALA2020012600218Floor Support · corrodedAFT CABIN FLOOR STRUCTURE AT Y765, FRAME 70 WAS CORRODED. REMOVED AND REPLACED AFT CABIN FLOOR STRUCTURE AT Y765 BETWEEN FRAMES 66 - 70 IAW 51-42-11 PAR 2.D, AND 51-49-00 TABLE 11.SDR AALA202001239021Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN WET AREA SHEAR PLATE BETWEEN FR 69 AND FR 70 AT +Y1162. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR A6WA2020012047113Intercostal · corrodedINTERCOSTAL JUST TO THE LEFT OF STRINGER 27 HAS CORROSION SPOTS BETWEEN FRAMES 364 AND 349, IN FWD E&E BAY. ORIGINAL MATERIAL .080, MATERIAL LOSS .009, .071 REMAINING. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-42-06 AND 51-4