JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022032275330Support · crackedLOWER FUSELAGE KEEL BEAM PANEL 191F FORWARD LH SUPPORT CLIP CRACKED / R&R LOWER FUSELAGE KEEL BEAM PANEL 192F FORWARD LH SUPPORT CLIP PER SRM 51-40-02SDR C77A2020020380032Floor Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-60259-001 FR90 RH OB GUSSET, P/N 170-60257-001 FR90 RH IB GUSSET, P/N 170-60257-001 FR90 SDR C77A2020020380031Gusset · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-60259-001 FR90 RH OB GUSSET, P/N 170-60257-001 FR90 RH IB GUSSET, P/N 170-60257-001 FR90 SDR C77A2020020380027Gusset · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-60259-001 FR90 RH OB GUSSET, P/N 170-60257-001 FR90 RH IB GUSSET, P/N 170-60257-001 FR90 SDR C77A2020020380025Floor Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING FORWARD CABIN FLOOR STRUCTURE: P/N 170-05663-003 (170-05663-005) RH FLOOR SILL, P/N 170-12114-001 RH FLOOR SPLICE, P/N 170-0SDR C77A2020020380024Floor Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING FORWARD CABIN FLOOR STRUCTURE: P/N 170-05663-003 (170-05663-005) RH FLOOR SILL, P/N 170-12114-001 RH FLOOR SPLICE, P/N 170-0SDR C77A2020020380023Floor Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING FORWARD CABIN FLOOR STRUCTURE: P/N 170-05663-003 (170-05663-005) RH FLOOR SILL, P/N 170-12114-001 RH FLOOR SPLICE, P/N 170-0SDR C77A2020020380022Doubler · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING FORWARD CABIN FLOOR STRUCTURE: P/N 170-05663-003 (170-05663-005) RH FLOOR SILL, P/N 170-12114-001 RH FLOOR SPLICE, P/N 170-0SDR REXA2019111281586Floor Support · crackedPRESSURE FLOOR SUPPORT CHANNEL @ FS 484.0 RBL 36 IB LEG CRACKED
LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE IB CLIP PN 601R31171-9 ON PRESSURE FLOOR SUPPORT CHANNEL AT FS 484 RBL 36 IAW CRJ 200 SRM 51-40-11 TR 51-42- AND 51-42-21.SDR SWAA2019110538612Door Sill · corrodedR1 DOOR INNER CHORD LOWER SILL CORRODED BETWEEN BS. 907 TO BS. 1006, RBL 57. / R&R INNER CHORD LOWER SILL IAW SRM AND DWG.SDR SWAA2019110438591Angle · corrodedAFT CARGO COMPARTMENT Z-ANGLE CORRODED BETWEEN BS. 727 TO BS. 847, LBL 21. / R&R Z-ANGLE IAW SRM.SDR SWAA2019110438590Angle · corrodedAFT CARGO COMPARTMENT Z-ANGLE CORRODED BETWEEN BS. 727+4 TO BS. 767, RBL 21. / R&R Z-ANGLE IAW SRM & DWG.SDR SWAA2019110438580Intercostal · crackedFORWARD GALLEY AND LAV FLOOR STRUCTURE WEB INTERCOSTAL CRACKED BETWEEN BS. 312 TO BS. 328, RBL 32. / R&R WEB-INTERCOSTAL IAW SRM AND DWG.SDR SWAA2019110438579Intercostal · crackedFLOOR STRUCTURE INTERCOSTAL - WEB CRACKED AT BS. 540, BETWEEN BL 0 TO LBL 24.5. / R&R INTERCOSTAL WEB IAW SRM AND DWG.SDR SWAA2019110438570Door Sill · corrodedR2 DOOR MOPSILL UPPER SURFACE CORRODED BETWEEN BS. 950 TO BS. 986, RBL 53. / R&R MOPSILL IAW SRM AND DWG.SDR SWAA2019110438569Door Sill · corrodedL2 DOOR MOPSILL UPPER SURFACE CORRODED AT BS. 986, LBL 47. / R&R MOPSILL IAW SRM AND DWG.SDR SWAA2019110438568Strap · corrodedUPPER SURFACE OF STRAP CORRODED BETWEEN BS. 1028 TO BS. 1016, RBL 18. / R&R STRAP IAW SRM AND DWG.SDR SWAA2019110438567Strap · corrodedUPPER SURFACE OF STRAP CORRODED BETWEEN BS. 1006 TO BS. 1030, BETWEEN RBL TO LBL 3. / R&R STRAP IAW SRM AND DWG.SDR SWAA2019110138453Angle · corrodedAFT CARGO COMPARTMENT R/H SIDE Z-ANGLE CORRODED BETWEEN BS. 727F TO BS. 767, RBL 21. / R&R Z-ANGLE IAW SRM.SDR SWAA2019102938351Web · corrodedAFT CARGO LOWER SILL WEB CORRODED BETWEEN BS. 794 TO BS. 847, RBL 27, ON UPPER SURFACE. / R&R WEB IAW SRM & DWG.SDR SWAA2019102938334Gusset · crackedFORWARD CARGO COMPARTMENT GUSSET CRACKED AT BS. 500D, STR. 19R. / R&R GUSSET IAW SRM AND DWG.SDR SWAA2019102938333Gusset · crackedFORWARD CARGO COMPARTMENT GUSSET CRACKED AT BS. 500D, STR. 19L. / R&R GUSSET IAW SRM AND DWG.SDR SWAA2019102838295Attach Angle · corrodedAFT CARGO ATTACH ANGLE COMMON TO LONGITUDINAL WEB CORRODED AT BS. 927+16, RBL 16, ON FORWARD FACE OF FLANGE. / R&R ATTACH ANGLE IAW DWG.SDR SWAA2019102838294Angle · corrodedAFT CARGO Z-ANGLE CORRODED ON UPPER AND LOWER SURFACE BETWEEN BS. 727C+10 TO BS. 767, RBL 23. / REPAIRED Z-ANGLE PER SRM.SDR SWAA2019102538230Angle · corrodedAFT CARGO Z-ANGLE CORRODED ON UPPER AND LOWER SURFACE BETWEEN BS. 727C8 TO BS. 787+12, LBL 23. / R&R Z ANGLE IAW SRM.SDR AALA201910259025Baffle · crackedAIRCRAFT IN BASE VISIT: BAFFLE CLIP CRACKED (.5INCH) AT STA 500G, S25R, RBL45. REMOVED AND REPLACED BAFFLE CLIP IAW BOEING DRAWING 143A7502 AND AARD 51-00-05.SDR AALA201910259030Door Sill · corrodedAIRCRAFT IN BASE VISIT: DOOR SILL -Y1732 AT FR68 CORRODED TWO PLACES AT NUTPLATES AT FR68, Y1732. REMOVED CORROSION FRABRICATED REPAIR ANGLE AND FILLER, INSTALLED SAME IAW SRM 53-41-14-300-001 AND SRM 51-42-11.SDR AALA201910259033Door Sill · corrodedAIRCRAFT IN BASE VISIT: CORROSION FOUND ON L2 DOOR SILL, FWD END OF FR66. INSTALLED FRAME REPAIR IAW SRM 53-41-14 FIG101.SDR REXA2019102481504Intercostal · corrodedINITIAL INSPECTION: CORROSION ON INTERCOSTAL 27(RH SIDE) AND 26R BTW. FS349 AND FS364 (FWD TO E/E DOOR) [IN REFERENCE TASK 900-53-140-300 APPENDIX A].(E/E)(TCI 100-09)
SUMMARY:INTERCOSTAL 27RH AND 26RH BTW. FS349 AND SDR SWAA2019102438177Web · corrodedFORWARD CARGO BAY BETWEEN CENTER CARGO LOWER DOOR THRESHOLD WEB CORRODED BETWEEN BS. 480+5 TO BS. 460+8, AREAS TOP SKIN. / R&R THRESHOLD WEB IAW DWG & SRM.SDR AALA201910249015Angle · corrodedAIRCRAFT IN BASE VISIT: LH TRANSITION ANGLE CORRODED AT 727D-847, LBL24. REMOVED AND REPLACED TRANSITION ANGLE IAW SRM 53-00-53-2R.SDR CALA2019102311784Angle · crackedMAIN FLOOR SUPPORT ANGLE APPEARS CRACKED AT FASTNER HEAD AT RBL55 STA 616 REF AAR N/R 99848350 INSTALLED REPAIR AT R/H MAIN FLOOR INNER CHORD STA 616 HOLE FASTNER FROM STA 601-639 RBL 55 AS PER RES WI2015189-51 AND ECRA 5315-01134.SDR CALA2019102311787Web · corrodedAFT PIT WEB BOX MANY CORROSION SPOTS PER HAECO LCQ NON ROUTINE 9 290735. REMOVED AND REPLACED AFT CARGO WEB BOX IAW A319 SRM 51-72-11-911 -001.SDR AALA201910229029Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED CABIN FLOOR SUPPORT ANGLE AT BS 540 AND RBL 1. REPLACED SUPPORT ANGLE PER AARD 51-00-05-1.SDR AALA201910229028Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED CABIN FLOOR SUPPORT ANGLE AT BS 540 AND LBL 1. REPLACED SUPPORT ANGLE PER AARD 51-00-05-1.SDR AALA201910219051Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRCKED FORWARD WET AREA FLOOR INTERCOSTAL BETWEEN BS 277 AND BS 293 AT BL 0. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA201910219031Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FORWARD WET AREA FLOOR INTERCOSTAL AT BS 290 AND BL 0. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR DALA2019102186021Roller Tray · corrodedMTC TASK-AFT CARGO ROLLER TRAY AT STA1153 AND LBL 6.5 FOUND CORROSION. REPAIRED THE AFT CARGO ROLLER TRAY AT STA1153 AND LBL 6.5 AS PER PRI 581515-14 REV.0&B767-400 SRM 53-00-53 REPAIR 1 REV.58 09/05 /2019.THE PRI 581515-14 REV.0 COMPLETED AND COMPLIED WITH ERSDR SWAA2022032275560Cap · corrodedFWD CARGO RH SIDEWAL TO FLOOR PANEL CAP STRIP HAS CORROSION ON LOWER SURFACE / REMOVED CORROSION FROM FWD CARGO RH SIDEWALL TO FLOOR PANEL CAP STRIP. NO SRM LIMITS GIVEN REPLACED PART ON SHELF IAW B737 SRM 51-10-02-0G-0 STEP 9 P/N 453A1611-5 'A' TAG A18452SDR SWAA2022032275556Scuff Plate · crackedFWD CARGO DOOR; AFT CORNER SCUFF PLATE IS CRACKED INTO 2 PIECES / ACCOMPLISHED WELD REPAIR ON FWD CARGO AFT CORNER SCUFF PLATE I.A.W EA. 1-A53-2076 REV II.SDR SWAA2022032275555Scuff Plate · crackedFWD CARGO DOOR; FWD CORNER SCUFF PLATE IS CRACKED INTO 2 PIECES / ACCOMPLISHED WELD REPAIR ON FWD CARGO FWD CORNER SCUFF PLATE I.A.W E.A 1-A53-2016 REV IR IISDR SWAA2022032232166Splice · corrodedAFT CARGO RH FLOOR CAP STRIP SPLICE HAS CORROSION AT STA 727D RBL 24. / AFT CARGO RH CAP STRIP SPLICE REQUIRES REPLACEMENT NO WRITTEN LIMITS NO DAMAGE ALLOWED @ STA 727D RBL 24. INSTALLED ON CUSTOMER CARD SA-M 565S ACCOMPLISHMENT REPLACED ON NRC Y117473SDR SWAA2022032209537Shield · corrodedAFT CARGO BAY RHT SHIELD FWD OF THE CARGO DOOR HAS AREAS OF CORROSION BS767 TO BS787 RBL23 WL156 / AFT CARGO BAY SHIELD BS767-787 RBL23 WL156 FOUND TO BE OUT OF LIMIITS DUE TO NO SRM LIMITS. REMOVED AND REPLACED SHIELD PER SRM 51-40-05-0G-0; SRM 51-40-02-0G-0;SDR SWAA2022032209536Strap · corrodedAFT CARGO BAY FLOOR STRAP AT BS767+6 HAS CORROSION FROM RBL 10 TO LBL10 WL156 / RECEIVED NEW ACB FLOOR STRAP FOR B.S 767+6 DUE TO SRM HAS NO ALLOWABLE LIMITS NEW PART WILL BE INSTALLED ON CUST. CARD # JPANEL-141-CLOSE NEW PART WAS RECEIVED ON PO# 765896SDR SWAA2022032209535Strap · corrodedAFT CARGO BAY FLOOR STRAP AT BS727D+6 HAS CORROSION FROM RBL 10 TO LBL10 WL156 / RECEIVED NEW ACB FLOOR STRAP FOR ACB B.S 727D+6 DUE TO NO SRM ALLOWABLE LIMITS. NEW PART WILL BE INSTALLED ON CUST. CARD # JPANEL-141-CLOSE NEW PART WAS RECEIVED ON CUST. PO# 7621SDR SWAA2022032209534Plate · corrodedAFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS727 TO BS767 RBL23 WL156 / REMOVED AND REPLACED ACB RH FLOOR TO SIDEWALL SUPPORT PLATE BS 727-767 RBL23 WL156 IAW SRM 51-40-02; SRM 51-40-05 AND DWG 146A7500SDR SWAA2022032209530Shield · corrodedFWD CARGO BAY RHT SHIELD BS495 TO BS500A HAS AREAS OF CORROSION RBL23 WL156 / CORROSION ON SHIELD BS 495-500A WL 156 FOUND TO BE OUT OF LIMITS DUE TO NO SRM LIMITS; REMOVED AND REPLACED SHIELD PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; DWG 143A0080.SDR SWAA2022032255121Panel · crackedCABIN FLOOR BOARD PNL 231NF TO 231KF PANEL BRAKES CRACKED. / REMOVED AND REPLACED CABIN FLOOR BOARD PNL 231NF TO 231KF PANEL BRAKES IAW AMM 53-21-00 AND SRM 51-40-02SDR C77A2020020430050Floor Support · corrodedDURING BASIC CHECK AT EAMS, CORROSION DAMAGE WAS DISCOVERED ON THE CENTER FUSELAGE III FLOOR STRUCTURE LONGITUDINAL BEAM INTERCOSTAL BETWEEN FRAMES 89-90. REFERENCE ETD2019-170-138520 FIGURES 1 FOR DETAILS, FOR THE DAMAGE LOCATIONS AND DIMENSIONS. EAMS REQUESTSDR C77A2020020380033Floor Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-60259-001 FR90 RH OB GUSSET, P/N 170-60257-001 FR90 RH IB GUSSET, P/N 170-60257-001 FR90
Back to JASC 5320