What was found
THIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-60259-001 FR90 RH OB GUSSET, P/N 170-60257-001 FR90 RH IB GUSSET, P/N 170-60257-001 FR90 LH IB GUSSET, P/N 170-60261-001 FR90 LH OB GUSSET, P/N 170-86181-005 FR89 RH PANEL SUPPORT, P/N 170-86107-001 FR89 SPLICE, P/N 170-65927-007 LH SHEAR PANEL. REPLACEMENT OF PARTS IS ACCOMPLISHED IN ACCORDANCE WITH EMBRAER DRAWINGS LISTED IN TABLE 2 AND SRM CHAPTER 51 PRINCIPLES. SUPPLEMENTAL FOLLOW UP INSPECTIONS WILL NOT BE REQUIRED FOR DIRECT REPLACEMENT OF THE FLOOR STRUCTURE. COMPASS ENGINEERING HAS CLASSIFIED THIS AS A MINOR REPAIR. WORK ORDER 2752898