SDR JR2R2019101369620Gusset · corrodedCORROSION ON GUSSET STA 24868 RBL 584.2SDR JR2R2019101369626Shear Web · corrodedCORROSION ON SHEAR WEB STA 24458 RBL 584.2 TO RBL 939.8SDR SWAA2022040563695Stiffener · brokenSTIFFENER BROKEN AT STA 663 RBL 6 TO RBL 30 WL 153 / REMOVED AND REPLACED WITH NEW STIFFNER AT STA 663 RBL 6 TO RBL 30 WL 153 PO# 746581 IAW SRM 51-40-05 AND DWG 111A1001. STIFFENER IS BEING TRANSFERRED TO TASK CARD NUMBER N226420; OF ALL WORK AND DOCUMENTATIOSDR SWAA2019111938959Stiffener · crackedCRACKED FOUND ON UPPER END OF VERTICAL STIFFENER AT STA 540 LBL 25 / R&R VERTICAL STIFFENER IAW EA.SDR REXA20191118595Support · crackedINITIAL INSPECTION: CRACK ON SUPPORT OF AC GROUND POWER CONNECTION RECEPTACLE. (FUS).
RECEPTACLE SUPPORT WAS REPLACED PER CRJ/900 SRM 51-42-13-001-001-A01SDR REXA2019111891385Access Panel · wornINITIAL INSPECTION: WORN HINGE PLATES ON LOWER CUT OUT ACCESS PANEL 122CR AND 122DR. (FUS).
ACCESS PANEL 122CR WAS REPLACED PER EA CRJ953-09836 REV IR AND ACCES PANEL 122DR WAS REPLACED PER EA CRJ953-09806 REV IR.SDR AALA201911139034Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON CABIN FLOOR INTERCOSTAL AT BS 947 AND LBL 25. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR SWAA2019102938341Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS. 727 TO BS. 847, LBL 20. / R&R SUPPORT PER SRM & DWG.SDR SWAA2019102938339Webbing · corrodedAFT CARGO BAY ON SUB THRESHOLD WEB CORRODED BETWEEN BS. 795 TO BS. 847, RBL 25. / R&R WEB PER SRM & DWG.SDR SWAA2019102938338Shield · corrodedAFT CARGO BAY AFT SHIELD CORRODED AT BS. 847+12, RBL 20. / R&R SHIELD IAW SRM AND DWG.SDR REXA2019102301557Bolt · missing"INITIAL INSPECTION: MISSING FITTING ATTACHED TO FWD RIGHT RAIL AND MISSING BOLTS OF HIS FITTING AT FWD BAGGAGE BAY. (CCD)
"
"NEW FITTING FWD RIGHT IN RAILAT FWD BAGGAGE BAY WILL BE INSTALLED UNDER CARD 900-53-900-125 STEP 29. SDR REXA2019102301556Helicoil · missing"INITIAL INSPECTION: MISSING HELICOIL INSERT IN FITTING ATTACHED TO AFT RIGHT RAIL AND MISSING BOLT OF HIS FITTING AT FWD BAGGAGE BAY. (CCD)
"
"NEW FITTING AFT RIGHT RAIL AT FWD BAGGAGE BAY WILL BE INSTALLED UNDER CARD 900-53-900-125 STEP 29. SDR REXA2019102301554Scuff Plate · worn"INITIAL INSPECTION: WAVINESS SCUFF PLATES AT FWD BAGGAGE BAY CUT-OUT.(CCD)
"SCUFF PLATES AT FWD BAGGAGE BAY CUT-OUT WERE REMOVED, PER EXCESSIVE DAMAGE WILL BE REPLACED AND NEW SCUFF PLATES AT FWD BAGGAGE BAY CUTOUT WILL BE INSTALLED UNDER CARD 900-53-900-125SDR AALA2019102199008Door Sill · unknownAIRCRAFT IN BASE MAINTENANCE: DURING THE CURRENT MAINTENANCE VISIT THE RIGHT HAND AFT DOOR CUT OUT LOWER SILL WHICH WAS PREVIOUSLY REPAIRED WAS REPLACED AND THE EXISTING REPAIR SPLICE ANGLE WAS REPLACED WITH THE PROPER SPLICE ANGLE AS OUT LINED IN THE APPLIACASDR DALA2019101535913Floor Support · corrodedCORROSION ON FLOOR SUPPORT STRUCTURE BTW STA 377-372, LBL 61. FLOOR SUPPORT WAS REPLACED PER. B757-200 SRM. 51-40-02 PAR, 4.SDR SWAA2022040407871Cap · corrodedCORROSION ON UPPER CHORD BS 986 RBL45 AND LBL45 AT NUTPLATE LOCATION / ON BS986 UPPER CHORD LBL 45 REPAIRED I.A.W SRM 53-70-51-2R-6 REPAIR 6 ALTERNATIVE 1 FIG 205 DUE TO FOUND OUT LIMIT AND BS 986 UPPER CHORD RBL 45 REMOVED CORROSION ON 2' X 1' AREA ORIGINAL MSDR SWAA2022040563693Support Channel · corroded***CORROSION*** FWD. CARGO COMPARTMENT; STA 510 BL 0 WL 148 UPPER SIDE OF SUPPORT ANTENNA HAS CORROSION. / CORROSION AT FWD CARGO COMPARTMENT STA 510 BL 0 WL 148 ON UPPER SIDE OF SUPPORT ANTENNA WAS FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS SHOWN INSDR AALA201911049009Transition Panel · corrodedAIRCRAFT IN BASE VISIT: CORROSION ON FORWARD CARGO COMPARTMENT LEFT HAND TRANSITION PANEL BETWEEN BS 460 AND BS 500I. REPLACED LT TRANSITION PANEL IAW SRM 53-00-53-2R/5. SUPPLEMENTAL REPORT: ENGINEERING REVIEWED THIS EVENT AND DETERMINED THE CORRECT LEVEL WAS SDR AALA201911139022Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR SUPPORT AT BS 947 AND RBL 20. REPLACED FLOOR SUPPORT PER AARD 51-00-05-1.SDR AALA201911139021Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON "Z" ANGLE AT BS 887 AND RBL 20, REPLACED "Z" ANGLE PER SRM 51-40-02.SDR HNAA2019110600348Door Sill · corrodedSERVICE DOOR CENTER SILL HAS AREAS OF CORROSION....FIX:REMOVED AND REPLACED SERVICE DOOR SILL IAW EMB 145 SRM 51-40-02. NOTE: A/C IN ABI HVY CHCKSDR AALA201911049008Floor Support · corrodedAIRCRAFT IN BASE VISIT: CORROSION ON #1 FLOORBOARD SUPPORT STA500H+14-18. INSTALLED NEW REPAIR/SPLICE TO LH TIE DOWN TRACK #1 IAW SRM 53-00-53-29-4.SDR IPXA2019103098430Intercostal · crackedINSPECTION TYPE:2CFWD. CARGO INTERCOSTAL IS CRACKED BETWEEN STA. 6-30 TO 6-50 AND ABOVE LONG. 43 R/H.REMOVED, FABRICATED AND REPLACED INTERCOSTAL BETWEEN STA. 6-30 TO 6-50 AND ABOVE LONG. 43 R/H IAW DWG. ACA7049 AND SRM 51-33-01. (MINOR)SDR AALA201910279013Channel · corrodedAIRCRAFT IN BASE VISIT: CORROSION ON Z CHANNEL AT STA 867.2, S25R, RBL16. INSTALLED NEW Z CHANNEL IAW AARD 51-00-05-1.SDR AALA201910279014Transition Panel · corrodedAIRCRAFT IN BASE VISIT: CORROSION ON TRANSITION PANEL AT STA 500A-500I, S25R. INSTALLED NEW TRANSITION PANEL IAW SRM 53-00-53-2R 5.SDR R61A2019102611146Floor Support · corrodedFLOOR SUPPORT FOUND CORRODED AT FR 89 RBL 36. R&R'D SUPPORT IAW SRM 51-43-03 AND SRM 51-42-01SDR R61A2019102611144Upper Sheet · corrodedON FLOOR STRUCTURE AT FR 85 RBL11, CORROSION FOUND ON UPPER SHEET. R&R'D UPPER SHEET IAW SRM 51-43-03 AND SRM 51-41-01SDR R61A2019102611142Gusset · corrodedFLOOR STRUCTURE AT FR 89 RBL 11, GUSSET PLATE FOUND CORRODED. R&R'D GUSSET PLATE IAW 51-43-03SDR SWAA2019102538185Stiffener · corrodedEXTRUDED STIFFENER CORRODED ON TOP BETWEEN BS. 986.5 TO BS. 1006, LBL 18. / R&R STIFFENER PER SRM.SDR R61A2019102561136Floor Support · corrodedFLOOR STRUCUTRE INTERCOSTAL FOUND CORRODED. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51-43-03SDR AALA201910249026Transition Panel · corrodedAIRCRAFT IN BASE VISIT: AFT CARGO LH TRANSITION PANEL HAS SEVERAL ARES OF CORROSION FROM BS727D-847, S25L. REMOVED AND REPLACED TRANSITION PANEL IAW SRM 57-00-05-1.SDR SWAA2019102238100Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS. 312 TO BS. 328, RBL 31. / R&R FLOOR SUPPORT PER SRM AND DWG.SDR SWAA2019102238099Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS. 328 TO BS. 344, LBL 45. R&R FLOOR SUPPORT PER SRM AND DWGSDR SWAA2019102238098Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS. 312 TO BS. 328, LBL 45. / R&R FLOOR SUPPORT PER SRM AND DWG.SDR SWAA2019102238067Channel · corrodedMOPSILL CHORD THRESHOLD SUPPORT FLANGE CORRODED BETWEEN BS. 900 TO BS. 1006, RBL 50. / R&R CHORD IAW SRM AND DWG.SDR AALA201910229018Strap · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON STRAP ATTACHED TO CREASE ANGLE AT BS 294.5 AND S17R. REPLACED AARD 51-00-05.SDR AALA201910119011Profile · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT CORNER PROFILE. REPLACED CORNER PROFILE PER SRM 51-42-11.SDR FDEA201910112605Cusp Web · corrodedMAIN CARGO AREA STA 1450 RH CUSP WEB CORRODED. REMOVED,FABRICATED AND INSTALLED NEW CUSP WEB IAW DWG 146N5590.SDR AALA201910179017Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO DOOR CUT OUT THRESHOLD WEB LOWER SURFACE AT BS 820 AND S24R. REPLACED WEB PER SRM 51-10-02.SDR AALA201910179016Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO DOOR CUT OUT THRESHOLD WEB AT BS 820 AND S24R. REPLACED WEB SRM 51-10-02.SDR AALA201910179015Channel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT TRANSITION "Z" CHANNEL BETWEEN BS 727D AND BS 767 AT S25R.SDR SWAA2019101657919Floor Support · crackedCABIN FLOOR INTERCOSTAL CRACKED BETWEEN BS. 312 TO BS. 328, RBL 30. R&R INTERCOSTAL PER SRM AND DWG.SDR SWAA2019101657918Floor Support · crackedCABIN FLOOR INTERCOSTAL CRACKED BETWEEN BS. 312 TO BS. 328, LBL 45. / R&R INTERCOSTAL PER SRM AND DWG.SDR SWAA2019101657887Floor Support · crackedCABIN FLOOR INTERCOSTAL CRACKED BETWEEN BS. 328 TO BS. 344, LBL 45. / R&R INTERCOSTAL PER SRM AND DWG.SDR DALA2019101405892Panel · corrodedALC BILGE PNL STA 1153-1175 LBL20-RBL20 CORROSION AT NUMEROUS PLACES. REPAIR BILGE PNAL IAW ERA 581853-14 REV O.SDR SWAA2022040561023Strap · corrodedAFT CARGO COMPARTMENT BILGE FLOOR SUPPORT STRAP HAS EXFOLIATING CORROSION AT STA 887 MKD DOT 60-009 / REMOVED AND REPLACED STRAP AT AFT CARGO COMPARTMENT PER REF 51-40-02-0G-0 AND 51-40-05-0G-0 AND DRAWING 146A9401 (STA 887).SDR SWAA2022040561015Channel · corrodedAFT CARGO COMPARTMENT R/H FLOOR SUPPORT ZEE CHANNEL CORRODED AND CRACKED AT FLANGE FROM STA 727C TO STA 767 / AT AFT CARGO COMPT R/H FLOOR SUPPORT ZEE CHANNEL CRACKED AT FLANGE REMOVED FROM STA 727 TO 767 IAW B737-700 SRM 51-40-02-0G-0; LOCATED AND DRILLED NEWSDR SWAA2022040437532Angle · corrodedFWD CARGO COMP L/H ZEE ANGLE HAS EVIDENCE OF SURFACE CORROSION SEVERAL PLACES FROM BS 432 TO BS 490 MKD 126-007. / FWD CARGO COMP. L/H ZEE CHANNEL FROM STA 396 TO STA 500D WAS REPLACED ON N/R W128373 (P/N 143A7501-80)SDR C77A2020020380029Shear Panel · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-60259-001 FR90 RH OB GUSSET, P/N 170-60257-001 FR90 RH IB GUSSET, P/N 170-60257-001 FR90 SDR C77A2020020380028Gusset · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-60259-001 FR90 RH OB GUSSET, P/N 170-60257-001 FR90 RH IB GUSSET, P/N 170-60257-001 FR90