SDR ASAA2019062930069Structure · corrodedMAIN CABIN INNER CHORD AT STA. 717 RBL 60 HAS CORROSION. GROUNDED - YES. CORRODED INNER CHORD AT FS 717 RBL 60 EXEEDED SERVICIABLE LIMITS IAW SRM 53-40-13, REMOVED DAMAGED INNER CHORD IAW SRM 51-40-02 RECIEVED NEW PART P/N: 144A5910-4, LOCATED, DRILLED AND INSSDR ASAA2019062929933Angle · crackedMAIN CABIN SECTION 43 INTERCOSTAL UPPER ANGLE AT STA. 380 TO STA. 400 BL 0 IS CRACKED. GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN SEC 43 INTERCOSTAL UPPER ANGLE AT FR 380 TOFS 400 AT BL 0 IAW DWG 143A5400 REV - AND SRM 51-40-02.SDR ASAA2019062929927Angle · crackedMAIN CABIN SECTION 43 INTERCOSTAL UPPER ANGLE AT STA. 380 TO STA. 400 LBL 10 IS CRACKED. GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN SEC 43 INERCOSTAL UPPER ANGLE AT FS 380 TO FS 400 LBL 10 IAW BAC DWG 143A5400 REV A AND SRM 51-40-02.SDR ASAA2019062929926Panel · crackedMAIN CABIN SECTION 43 PANEL BREAK AT STA. 540 BL 0 TO RBL 24 IS GOUGED. GROUNDED - YES. REMOVED AND REPLACED GOUGED PANEL BREAK AT MAIN CABIN STA. 540, BL 0 TO RBL 24 IAW SRM 51-40-02 AND BAC DWG 143A0060 REV "-".SDR REXA2019062901034Mount · corroded"INITIAL INSPECTION: CORROSION ON LOWER FRAME BETWEEN FS319 TO FS349 OF THE GALLEY SERVICE DOOR SURROUND STRUCTURE (SM) (CPAX) "SUMMARY OF NRC:00177 CORROSION LEVEL: 2 DUE TO EXCESSIVE CORROSION ON ANGLE MOUNTING BETWEEN FS319 TO FS349 WILL BE REPLACED: ORIGINSDR REXA2019062901081Floor Support · crackedAWR; PER MTC REQUEST: [ DURING REMOTION OF RIGHT FITTING TO INSTALL RIVETS (ITEM 6), RELATED WITH TASK R53581 STEP 23 ]: CRACK IN LONGITUDINAL FLOORBEAM 12RBL [ LOOKING THROUGH ACCESS 221ALF FLOOR STRUCTURE ] AT COCKPIT. (CPIL)
LONGITUDINAL FLOORBEAM 12RBL [ SDR ASAA2019062929919Panel · crackedMAIN CABIN SECTION 43 PANEL BREAK AT STA. 540 BL 0 TO LBL 24 IS CRACKED GROUNDED - YES. REMOVED AND REPLACED PNL BREAK AT FS 540 BL 0 TO LBL 24 IAW BAC DWG 143A0060 REV.SDR AALA201907029040Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-72-11.SDR DALA2019063003989Intercostal · corroded(LOG 1147330) DURING INSPECTION FOUND CORROSION WEB - INTERCOSTAL LOCATED BETWEEN BS 500 TO BS 500A AT LEVEL STR 26R AT FWD CARGO COMPARTMENT. REPLACED WEB-INTERCOSTAL LOCATED BETWEEN BS500 TO BS 500A AT LEVEL STR 26R AT FWD CARGO COMPARTMENT AS PER SRM 51-10-SDR CALA2019070201110Intercostal · crackedPASSENGER CABIN INTERCOSTAL BETWEEN STA 344 AND STA 360, BL 0, IS CRACKED, [MKD 78-20] REMOVED AND RPELACED INTERCOSTAL BETWEEN STA 344 AND STA 360 BL0 PER REF SRM 51-40-02 DWG 141A5400.SDR IPXA2019063043895Floor Support · corrodedINSPECTION TYPE:10YR SUPERNUMARY AREA FLOORBEAM UNDER PANEL 221VF HAS CORROSION ON UPPER SURFACE. ACCOMPLISHED BLEND OUT REPAIR ON MAIN CABIN FLOOR SUPPORT AT FR 14 STA Y 953 PER EA# 300-5312-01-A7820 I/R AND EO A300-5310-73069-A.SDR FOTR20190629012Shear Plate · corrodedAFT CABIN FLOOR 7" FWD OF FR70 SHEAR PLATE HAS CORROSIONSDR FOTR201906290011Support Frame · corrodedAFT CABIN FLOOR 7" FWD OF FRAME70 LH SHEAR PLATE HAS CORROSION.SDR SWAA2022031160466Scuff Plate · crackedFCB FWD SCUFF PLATE IS CRACKED / REPAIRED FWD CARGO BAY FWD SCUFF PLATE IAW SWA EA 1-A53-2076 REV 11SDR CA190726019Floor Support · corroded(CAN) LBL 9 & RBL 9 FLOOR BEAM CORRODED ON INBOARD SIDE BETWEEN F.S. 661.00+74 AND F.S. 661.00+90. FLOOR BEAM LHS P/N SH690-33413-7, FLOOR BEAM RHS P/N SH690-33402-9, (TC# 20190726019)SDR K11A2019081273202Floor Support · crackedMAIN DECK LONGITUDINAL FLOORBEAM UPPER CHORD CRACKEDSDR SWAA2019072235192Floor Support · corrodedAFT CARGO BAY BILGE NUTPLATES AT FLOOR SUPPORT CARGO TIE-DOWN CORRODED AT BS. 907, LBL 3. R&R SUPPORT CARGO TIE-DOWN IAW SRM AND DWG.SDR REXA201907161093Support Angle · corrodedINITIAL INSPECTION. CORROSION ON FLOOR SUPPORT ANGLE FS 280 RBL9-LBL9. (CPAX)(SM)(TCI 53-10-219). FLOOR SUPPORT ANGLE FS 280 RBL9-LBL9 WAS REPLACED FOR A NEW ONE PER SRM 51-42-06-001-001-A01 PAR 6 (LEVEL CORROSION 2)SDR R61A201906280694Angle · cracked*** AIRCRAFT IS IN HEAVY CHECK*** COCKPIT FLOOR STRUCTURE CROSSBEAM FR 12, LBL 38, ANGLE CRACKED. REPLACED ANGLE IAW SRM 51-41-01. ***AIRCRAFT REMAINS IN HEAVY CHECK***SDR R61A201906280693Angle · cracked*** AIRCRAFT IS IN HEAVY CHECK*** COCKPIT FLOOR STRUCTURE CROSSBEAM FR 12, BL 0, ANGLE CRACKED. REPLACED ANGLE IAW SRM 51-41-01. ***AIRCRAFT REMAINS IN HEAVY CHECK***SDR REXA2019062801080Floor Support · crackedAWR; PER MTC REQUEST: [ DURING REMOTION OF LEFT FITTING TO INSTALL RIVETS (ITEM 6), RELATED WITH TASK R53581 STEP 23 ]: CRACK IN LONGITUDUNAL FLOORBEAM 12LBL [ LOOKING THROUGH ACCESS 221ALF FLOOR STRUCTURE ] AT COCKPIT. (CPIL)
LONGITUDINAL FLOORBEAM 12LBL [ LSDR R61A201906280675Shear Web · corroded***WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK*** CENTER FUSELAGE III FLOOR STRUCTURE RH SHEAR WEB BETWEEN FR 87-88 RBL 36 AND RBL 20 FOUND CORRODED. CENTER FUSELAGE III FLOOR STRUCTURE RT SHEAR WEB BTWN FR 87-88 RBL 20-LBL 20 BOTH REPLACED IAW SRM 51-42-01 &SDR R61A201906280674Gusset · corroded***WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK*** CENTER FUSELAGE III FLOOR STRUCTURE GUSSET PLATE AT FR 90 RBL 20 FOUND CORRODED. CENTER FUSELAGE III FLOOR STRUCTURE GUSSET PLATE AT FR 90 RBL 20 REPLACED IAW SRM 51-41-02. A/C REMAINS OUT OF SERVICE FOR HEAVSDR R61A201906280673Gusset · corroded***WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK*** CENTER FUSELAGE III FLOOR STRUCTURE GUSSET PLATE AT FR90 AND RBL12 FOUND CORRODED. CENTER FUSELAGE FLOOR STRUCTURE GUSSET AT FR90 AND RBL12 REPLACED IAW SRM 51-41-02. A/C REMAINS OUT OF SERVICE FOR HEAVY CHECKSDR DALA2019070103965Door Sill · dirtySHIP 689 1R DOOR WILL NOT ARM. CORRECTIVE ACTION: REMOVED DEBRIS FROM DOOR SILL. (5809688)SDR IPXA2019070143937Track · crackedINSPECTION TYPE:3C FWD. AVIONICS ACCESS DOOR RT TRACK IS CRACKED. REMOVED AND REPLACED TRACK IAW SRM 51-31-01 & 51-33-01. (MINOR)SDR DALA2019062903940Cusp Web · corrodedCORROSION ON CUSP MEMBRANE (WEB) FROM Y= 965 TO Y=986 RT SIDE (PAX CAB). NRC 00510: CORROSION LEVEL 2, CORROSION WAS REMOVED ON STA Y=979 TO Y=981 PER SRM 51-10-04-0G PAR 26, A10X MAGNIFIED INSPECTION WAS PERFORMED AND A CRACK OF 0.380" LENGTH WAS FOUND AND RESDR SWAA2022031133013Scuff Plate · crackedAFT CARGO BAY FWD CORNER SCUFF PLATE IS CRACKED / RECEIVED NEW PART OK TO INSTALL INSP 345 02JUL19 INSTALLED NEW FWD CORNER SCUFF PLATE I/A/W A.M.M 53-11-02-420-801SDR SWAA2022031133014Scuff Plate · crackedFWD CARGO BAY AFT CORNER SCUFF PLATE IS CRACKED / REMOVED; WELDED; AND RE-INSTALLED FCB AFT CORNER SCUFF PLATE IAW EA 1-A53-2076; REV 11.SDR SWAA2022031133015Scuff Plate · crackedAFT CARGO BAY AFT CORNER SCUFF PLATE IS CRACKED / REMOVED AND REPLACED AFT CORNER SCUFF PLATE AT AFT CARGO BAY I/A/W A.M.M. 53-11-02-420-801SDR SWAA2022031147626Angle · crackedAFT CARGO BAY SHIELD ATTACH ANGLE CRACKED BS 785 RBL 21 WL 155 / REPLACED AFT CARGO BAY SHIELD ATTACH ANGLE AT BS 785 RBL 21; WL 155; IAW SRM 51-40-02-0G-0 AND DWG 1468123. 59533U 3JUL19SDR SWAA2022031147627Angle · crackedAFT CARGO BAY SHIELD ATTACH ANGLE CRACKED BS 791 RBL 21 WL 155 / REMOVED CRACKED AFT CARGO BAY SHIELD ATTACH ANGLE AT BS 791; RBL 21; WL 155 IAW SRM 51-40-02 INSTALLED NEW ATTACH ANGLE IAW SRM 51-40-02 AND DWG 146A0081.SDR SWAA2022031165246Angle · crackedACB ANGLE CRACKED BS 867 LBL 18 / REMOVED DAMAGED ANGLE AND INSTALLED NEW ANGLE AT BS 867 LBL18 WL156 IAW SRM 51-40-02 AND DWG 149A8102SDR SWAA2022031165254Angle · crackedACB BULKHEAD ANGLE CRACKED BS 727+4 RBL 3 / REMOVED & REPLACED THE BULKHEAD ANGLE ACB BS 727+4 RBL 3 INSTALLED PER DWG 144A2600SDR SWAA2022031165248Strip · corroded***CORROSION*** ACB NUTPLATE STRIP IS CORRODED BS 787 - 794 RBL 18WL / REMOVED CORRODED NUTPLATE STRAP AND ISTALLED NEW NUTPLATE STRAP AT BS 787-794 RBL18 WL156 IAW SRM 51-40-02 AND DWG 146A0081SDR SWAA2022031165247Strip · corroded***CORROSION*** ACB NUTPLATE STRIP IS CORRODED BS 794 TO 803 RBL 18 WL 156 / REMOVED CORRODED NUTPLATE STRAP AND INSTALLED NEW NUTPLATE STRAP AT BS 794-803 RBL18 WL156 IAW SRM 51-40-02 AND DWG 146A0081SDR SWAA2022031165245Strap · corroded***CORROSION*** ACB NUTPLATE STRIP 838-847 RBL 18 HAS CORROSION WL 156 / REMOVED CORRODED NUTPLATE STRAP AND INSTALLED NEW NUTPLATE STRAP AT BS 883-847 RBL 18 WL 156 IAW SRM 51-40-02 AND DWG 146A0081SDR SWAA2022031102828Angle · crackedEXTERNAL FUSELAGE; STA 1016+3; LBL 11; 7' ABOVE FUSELAGE SKIN; LATTERAL ANGLE IS CRACKED IN RADIUS (COMMON TO FWD VERTICAL STAB A-FRAME FITTING) / REPMOVED AND REPLACED LATTERAL ANGLE P/N L776A3101-26 A TAG A84524 IAW BOEING DWG 3 176A3001 REV A.SDR CA190725009Floor Support · corroded(CAN) UPON INSPECTION, CORROSION FOUND ON THE RH FLOOR SILL INTERCOSTAL BETWEEN FS 559 TO FS 559+16. (TC# 20190725009)SDR C77A2020031100026Panel Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-86101-001 LH UPPER SHEET, P/N 170-92856-001 FLOOR DOUSDR C77A2020022470034Panel Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-86101-001 LH UPPER SHEET, P/N 170-92856-001 FLOOR DOUSDR C77A2020022470033Floor Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-86101-001 LH UPPER SHEET, P/N 170-92856-001 FLOOR DOUSDR C77A2020022470032Floor Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-86101-001 LH UPPER SHEET, P/N 170-92856-001 FLOOR DOUSDR C77A2020022470031Gusset · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-86101-001 LH UPPER SHEET, P/N 170-92856-001 FLOOR DOUSDR C77A2020022470030Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-86101-001 LH UPPER SHEET, P/N 170-92856-001 FLOOR DOUSDR C77A2020022470029Support · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-86101-001 LH UPPER SHEET, P/N 170-92856-001 FLOOR DOUSDR C77A2020022470028Doubler · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIRS OF CORROSION DAMAGE BY REPLACEMENT OF THE FOLLOWING AFT CABIN FLOOR STRUCTURE: P/N 170-92907-001 LH PANEL SUPPORT, P/N 170-86101-001 LH UPPER SHEET, P/N 170-92856-001 FLOOR DOUSDR SWAA2019072935356Support · corrodedAFT CARGO BAY ON LT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS. 727 TO BS. 787, LBL 22. R&R SUPPORT IAW SRM AND DWG.SDR SWAA2019072935312Support · corrodedAFT CARGO BAY ON R/H FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS. 727 TO BS. 767, RBL 22. R&R SUPPORT IAW SRM AND DWG.SDR AALA201907229056Plate · crackedAIRCRAFT IN BASE MAINTENANCE: AFT WET AREA TRAY PLATE CRACKED BETWEEN FR 68 AND FR 69 AT S23R. REPLACED TRAY PLATE PER SRM 51-72-11.