What was found
INSPECTION TYPE:10YR SUPERNUMARY AREA FLOORBEAM UNDER PANEL 221VF HAS CORROSION ON UPPER SURFACE. ACCOMPLISHED BLEND OUT REPAIR ON MAIN CABIN FLOOR SUPPORT AT FR 14 STA Y 953 PER EA# 300-5312-01-A7820 I/R AND EO A300-5310-73069-A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:10YR SUPERNUMARY AREA FLOORBEAM UNDER PANEL 221VF HAS CORROSION ON UPPER SURFACE. ACCOMPLISHED BLEND OUT REPAIR ON MAIN CABIN FLOOR SUPPORT AT FR 14 STA Y 953 PER EA# 300-5312-01-A7820 I/R AND EO A300-5310-73069-A.