Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2019050732393Shield · corrodedFORWARD FLOOR SHIELD CORRODED AT BS. 780, RBL 21. R&R SHIELD PER SRM & DWG.SDR SWAA2019050732391Strap · corrodedFLOOR PANEL SUPPORT STRAP CORRODED AT BS. 754, BETWEEN RBL 21 TO LBL 21. R&R STRAP PER DWG AND SRM.SDR SWAA2019050732390Threshold · corrodedAFT CARGO PIT SUB THRESHOLD WEB CORRODED BETWEEN BS. 794 TO BS. 847, RBL 26. R&R WEB PER SRM AND DWG.SDR SWAA2019050632300Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS. 344 TO BS. 360, LBL 11. R&R INTERCOSTAL IAW SRM & DWG.SDR SWAA2019050332252Attach Angle · corrodedR1 DOOR SCUFF PLATE ATTACH ANGLE CORRODED BETWEEN BS. 310 TO BS. 318, RBL 58. R&R ANGLE IAW SRM AND DWG.SDR SWAA2019050132178Gusset · crackedGUSSET CRACKED AT BS. 500D, STR. 19R. R&R GUSSET IAW SRM & DWG.SDR SWAA2019050132139Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS. 344 TO BS. 360, LBL 1. R&R INTERCOSTAL IAW SRM & DWG.SDR SWAA2019050132138Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS. 312 TO BS. 328, LBL 45. R&R INTERCOSTAL IAW SRM AND DWG.SDR SWAA2019050132137Intercostal · crackedINTERCOSTAL CRACKED BETWEEN BS. 277 TO BS. 294, RBL 1. R&R INTERCOSTAL IAW SRM AND DWG.SDR SWAA2019050132135Attach Angle · corrodedL1 DOOR SCUFF PLATE ATTACH ANGLE CORRODED BETWEEN BS. 317 TO BS. 338, LBL 60. R&R ANGLE IAW SRM & DWG.SDR SWAA2019050132134Strap · corrodedAFT CABIN FLOOR STRAP CORRODED AT BS. 1016, LBL 3.54, BETWEEN AND PRESSURE BULKHEAD. R&R STRAP IAW SRM AND DWG.SDR AALA201904309032Channel · burnedAIRCRAFT IN BASE MAINTENANCE: LOWER FORWARD NOSE INTERNAL STRUCTURE HAS A HOLE BURNT ON THE FRAME LOWER CHANNEL FROM A SHORT WITH THE IINTERNAL SIDE OF THE PWER RECEPTACLE AT FR 13 AND S23L. REPLACED CHANNEL PER SRM 51-40-01.SDR DALA2019042952717Floor Support · corrodedCORROSION ON FLOOR SUPPORT FROM STA 1640 TO 1681 LBL 0 AT PASSENGER CABIN FLOOR STRUCTURE. CORRECTIVE ACTION: SUMMARY OF NRC 00241: LEVEL CORROSION 2. FLOOR SUPPORTS FROM STA 1640 TO 1681 LBL 0 AT PASSENGER CABIN FLOOR STRUCTURE WITH CORROSION OUT OF LIMITS WESDR AALA201904295002Strap · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOOR STRAP AT BS 1006 AND RBL3. REPLACED STRAP PER SRM 51-40-02.SDR A6WA20190426580Vertical Support · crackedSTA 409+128 VERTICAL POST CRACKED IN RADIUS. REPLACED VERTICAL POST IAW REO601R-53-41-889 REV-D AND CRJ200 SRM 51-42-06.SDR A6WA20190426579Vertical Support · crackedSTA 409+128 BL0, VERTICAL POST HAS A CRACK ON L/H SIDE AFT ANGLE, WL69. REPLACED VERTICAL POST IAW REO 601R-53-41-899 REV-D, CRJ200 SRM 51-42-06.SDR A6WA201900426574Channel · crackedCHANNEL BEHIND HYD. SYS. 2 PRESSURE/RETURN MANIFOLD IS CRACKED. REPAIRED CHANNEL IAW REO 601R-53-62-031 REV-A.SDR AALA201904254006Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOOR SUPPORT BETWEEN BS 992 AND BS 1016 AT RBL 32. REPLACED FLOOR SUPPORT PER AARD 51-00-05-1.SDR AALA201904254005Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: FORWARD WET AREA FLOOR INTERCOSTAL CRACKED BETWEEN BS 328 AND BS 344 AT LBL 32. REPLACED INTERCOSTAL PER SRM 51-40-02 AND AARD 51-00-05-1.SDR AALA201904254004Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: FORWARD WET AREA FLOOR INTERCOSTAL CRACKED BETWEEN BS 312 AND BS 328 AT LBL 32. REPLACED INTERCOSTAL PER SRM 51-40-02 AND AARD 51-00-05-1.SDR AALA201904254003Stiffener · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON APU INLET AREA HORIZONTAL STIFFENER BETWEEN BS 1088 AND BS 1156. REPLACED STIFFENER PER SRM 51-10-02 AND AARD 51-00-05.SDR AALA201904254002Stiffener · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON APU COMPARTMENT VERTICAL STIFFENER AT BS 1125. REPLACED STIFFENER PER SRM 51-10-02 AND AARD 51-00-05.SDR CA190423015Intercostal · corroded(CAN) DURING SCHEDULED INSPECTION, LEVEL 2 CORROSION FOUND ON L//H INTERCOSTAL BETWEEN FS 349 AND 364, STRINGER 27. PART REPLACEMENT CARRIED OUT IAW MANUFACTURER SRM. PN (TC# 20190423015)SDR WVER2019070838Beam · chafedAFT BAGGAGE BAY BEAM IS CHAFED ON FWD AND AFT END FROM THE COUNTERBALANCE CABLE.SDR SWAA2019051432664Door Sill · corrodedMOPSILL CORRODED BETWEEN BS. 277 TO BS. 360, LBL 60. R&R MOPSILL IAW SRM AND DWG.SDR SWAA2019051332569Intercostal · crackedINTERCOSTAL CRACKED AT FASTENER HOLE BETWEEN BS. 277 TO BS. 294.5, RBL 1. R&R INTERCOSTAL IAW SRM AND DWG.SDR REXA2019042300618Angle · crackedAFT EQUIPMENT COMPARTMENT FS 621.00 TO 625.00 OBLIQUE ANGLE AT STR 14L IN CRACKED. REMOVED AND REPLACED OBLIUQUE ANGLE AT STR14L IAW SRM 51-42-21 P/N 601-35012-51.SDR IPXA2019050941941Support Angle · crackedINSPECTION TYPE:4C AFT FUSELAGE COMP. AT STA. 2123 ON CIELING, THE SKIN SUPPORT ANGLE IS CTRACKED.REMOVED, FABRICATED AND REPLACED SUPPORT AT STA. 2123 IAW DWG. AKC7372 AND SRM 51-33-01. (MINOR)SDR SWAA2019050832446Support Angle · corrodedFORWARD ENTRY DOOR INBOARD THRESHOLD SUPPORT ANGLE CORRODED BETWEEN BS. 312 TO BS. 344, LBL 60. R&R ANGLE IAW SRM AND DWG.SDR REXA2019042300601Floor Support · corrodedINITIAL INSPECTION: CORROSION ON FLOORBEAM 27LBL IN STA. FS= 980 TO FS= 1055 AT AFT BAGGAGE BAY. (CCT) (TCI 100-15) LEVEL CORROSION 2. FLOORBEAM 27LBL IN STA. FS= 980 TO FS= 1055 AT AFT BAGGAGE BAY WAS REPAIRED PER SRM 53-00-41-201-001-A03 PAR. 5.B.SDR SWAA2019050732363Attach Angle · corrodedINTERCOSTAL ATTACH ANGLE CORRODED BETWEEN BS. 767 TO BS. 787, RBL 21. R&R ANGLE PER SRM & DWG.SDR IPXA2019050141634Support Angle · crackedINSPECTION TYPE:4C AFT FUSELAGE COMPARTMENT CROWN AREA SUPPORT ANGLE (CLIP) IS CRACKED AT LT SIDE AT STA. 2014. REPAIRED CRACKED AFT FUSELAGE SUPPORT ANGLE (CLIP) AT LT SIDE STA. 2014 IAW SRM 53-70-07. (MINOR)SDR YENA2019042930236Threshold · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THRESHOLD SHEET BTW FR 52A TO 56 IN AFT COMPARTMENT; REPLACED THRESHOLD SHEET BTW FR 52A TO FR 56 IN AFT CARGO COMPARTMENT IAW A320 SRM 51-72-11. WORK ACCOMPLISHED ON AERMAN NR 2019-133568SDR YENA2019042930234Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON HOLRS FLOOR BEAM -Y765 BTW FRAME 64 TO FRAME 66 AT AFT GALLEY AREA; REPLACED FLOOR BEAM -Y765 BTW FR 64 TO FRAME 66 AT AFT GALLEY AREA IAW A320 SRM 51-72-11. WORK ACCOMPLISHED ON AEROMAN NR 2019-133614.SDR YENA2019042930233Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL BTW FR 66 TO FR 68 AT STR 23R AT AFT GALLEY; REPLACED LOWER SILL BTW FR 66 TO FR 68 AT STR 23R AT AFT GALLEY AREA. IAW A320 SRM 51-42-11. WORK ACCOMPLISHED ON AEROMAN NR 2019-133626.SDR YENA2019042930232Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL BTW FR 60 TO FR 62 AND STR 38R IN AFT CARGO COMPARTMENT; REPLACED LOWER SILL BTW FR 60 TO FR 62 AND STR 38R IAW A320 SRM 51-41-11. WORK ACCOMPLISHED ON AERMAN NR 2019-133569SDR YENA2019042930231Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL BTW FR 60 TO FR 62 AND STR 38R IN AFT CARGO COMPARTMENT; REPLACED LOWER SILL BTW FR 60 TO FR 62 SND STR 38R IAWA320 SRM 51-72-11. WORK ACCOMPLISHED ON AEROMAN NR 2019-133569SDR YENA2019042930230Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL BTW FR 60 TO 62 AND STR 39R IN AFT CARGO COMPARTMENT; REPLACED LOWER SILL BTW FR 6O TO FR 62 STR 38R IAW A320 SRM 51-72-11. WORK ACCOMPLISHED ON AEROMAN NR 2019-133569.SDR YENA2019042930229Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SILL BTW FR 60 TO FR 20 AND STR 38R IN AFT CARGO COMPARTMENT (1 EA); REPLACED LOWER SILL BTW FR 60 TO FR 62 AND STR 38 IAW A320 SRM 51-42-11. WORK ACCOMPLISHED ON AEROMAN NR 2019-133569SDR YENA2019042930228Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y1162 BTW FR 68 TO FR 69 AFT GALLEY AREA; REPLACED FLOOR BEAM -Y1162 LOC BTW FR 68 TO FR 69 AFT GALLEY AREA IAW A320 SRM 51-42-11. WORK ACCOMPLISHED ON AEROMAN NR 2019-133647SDR YENA2019042930227Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON HOLES FLOOR BEAM LOC BTW FRAME 64 TO FRAME 66 -Y1292 AT GALLEY AREA; REPLACED FLOOR BEAM LOC BTW FRAME 64 TO FR 66 -Y1292 IAW A320 SRM 51-42-00. WORK ACCOMPLISHED IN AEROMAN NR 2019-133611SDR YENA2019042930226Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON UNDERFLOOR STRUCTURE WEB AT LEVE OF STGR 23R BTW FR 69 TO FR 70 AT AFT GALLEY; REPLACED WEB AT LEVEL 23R BTW FR 69 TO FR 70 AT AFT GALLEY AREA IAW A320 SRM 51-42-11. WORK ACCOMPLISHED ON AEROMAN NR 2019-133SDR YENA2019042930225Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y512 BTW FR 64 TO FR 67 AT GALLEY AREA; REPLACED FLOOR BEAM -Y512 BTW FR 64 TO FR 67 AT AFT GALLEY AREA IAW A320 SRM 51-42-11. WORK ACCOMPLISHED OM AEROMAN NR 2019-133618SDR YENA2019042930224Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM +Y512 BTW FR 64 TO FR 67 AT GALLEY AREA; REPLACED FLOOR BEAM +Y512 BTW FR 64 TO FR 67 AT AFT GALLEY AREA IAW A320 SRM 51-42-11. WORK ACCOMPLISHED ON AEROMAN NR 2019-133627SDR YENA2019042930223Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM LOC BTW FRAME 64 TO 67 +10 -Y464 AT GALLEY AREA; REPLACED FLOORBEAM LOC BTW FR 64 TO FR 67 +10 -Y464 AT AFT GALLEY AREA IAW A320 SRM 51-42-11. WORK ACCOMPLISHED ON AEROMAN NR 2019-133624SDR YENA2019042930222Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED UNDER FLOOR STRUCTURE WED AT LEVEL OF STRG 23L AND BETWEEN FR 69 TO FR 70 AT AFT GALLEY AREA; REPLACED UNDER FLOOR STRUCTURE WED AT LEVEL OF STRG 23L AND BETWEEN FR69 TO FR 70 AT AFT GALLEY AREA IAW SRM 51-72-SDR CALA2019042600641Floor Support · corrodedAFT CARGO COMP. FLOOR STR AT APPROX. FS1374 RBL 1610HAS CORRODED NUT PLATE. 56-006. REF VTSAA N/R 0053546. REPAIRED STRINGER AT AFT CARGO COMPARTMENT FS 1374 RBL 1610 IAW B757-3 SRM 53-00-53 REPAIR 1. ESFR NO.1021541. SEE SUPPLEMENT 85 533.SDR CALA2019042600640Floor Support · corrodedAFT CARGO COMP, FLOOR STR AT APROX FS1374 LBL 7 .55 HAS CORRODED NUT PLATE. 56-005. REF VTSAA N/R 0053543. REPAIRED STRINGER AT AFT CARGO COMPARTMENT FLOOR STR AT FS 1374 LBL 7.55 IAW B757-3 SRM 53-00-53 REPAIR 1. SEE SUPPLEMENT 85534. ESFR 1021540. WORK ACCOMSDR R61A201904230411Support · corrodedDURING HEAVY CHECK VISIT FOUND CORROSION-FWD WET AREA LH MONUMENT SUPPORT FR16. REMOVED AND REPLACED MONUMENT SUPPORT PN170-13633-001 FR16 REF SRM 51-40-08. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.SDR R61A201904230410Gusset · corrodedDURING HEAVY MAINT CHECK VISIT FOUND CORROSION ON AFT WET AREA RH GUSSET PLATE FR90. REMOVED AND REPLACED GUSSET AFT WET AREA FR90 REF. SRM 51-40-08. RESTORED SURFACE PROTECTION REF. EMB SRM 51-23-05. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION
Back to JASC 5320