JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A201904230409Floor Splice · corrodedDURING HEAVY CHECK VISIT FOUND CORROSION ON AFT WET AREA FLOOR SPLICE AT FR90 Y= -10.748. REMOVED AND REPLACED AFT WET AREA FLOOR SPLICE AT FR90 Y= -10.748" REF. EMB SRM 51-40-08.RESTORED SURFACE PROTECTION REF. EMB SRM 51-23-05, 51-23-06. ACFT REMAINS IN HEASDR SWAA2022030734018Doubler · crackedEGPR HAS AN APPROX. 1' LONG CRACK THROUGH FASTENER AT LOWER EDGE OF EGPR CUTOUT. CRACK IS LOCATED AT BS.231. / REPAIRED EGPR DOUBLER IAW SRM 53-10-15 ZONE 2 REPAIR ; FIG 204SDR SWAA2019052032832Support Angle · corrodedWING BOX CENTER SECTION UPPER WEB SUPPORT ANGLE CORRODED AT BS. 663, RBL 47. REPAIRED ANGLE IAW EA.SDR AALA201905139049Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FITTING AT FR 16 AND S10L. REPLACED FITTING PER SRM 51-72-11.SDR AALA201905099029Vapor Barrier · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED VAPOR BARRIER ON THE AFT SIDE OF THE LEFT HAND ESC BAY NEAR BOTTOM OF STIFFENER AT LBL 31.83. REPAIRED PER SRM 57-10-10-2R-2 AND 57-10-9.SDR AALA201905099028Vapor Barrier · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN VAPOR BARRIER ON AFT SIDE OF RIGHT HAND ESC BAY NEAR BOTTOM STIFFENER AT RBL 15.54. REPAIRED PER SRM 57-10-10-2R-2 AND 57-10-10-9.SDR AALA201905099016Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERCOSTAL FITTING AT FR 16 AND S10R. REPLACED INTERCOSTAL FITTING PER SRM 51-42-11.SDR SWAA2019050832436Support · crackedCABIN FLOOR PANEL SUPPORT CRACKED AT BS. 540, BETWEEN BL 0 TO LBL 20. R&R SUPPORT IAW SRM AND DWG.SDR UIEA2019042604021Web · crackedBS 990 S38R-39R CRACK FOUND AT 1 EA FASTENER HOLE OF WEB WHICH COMMON TO BATH LWR FITTING(<P>CAT C REPAIR COMPLETED LAW RL-53-00-13524 REV B WITH FOLLOW UP ACTION OF CAT A OR B REPAIR OR MODIFICATION TO BE COMPLETED WITHIN 24 MONTHS OR 1,700 FLIGHT CYCLES WHICSDR UIEA2019042543946Stiffener · corrodedKEEL BEAM, R/H O/B STIFFENER AT STA 786 BULKHEAD HAS CORROSION. (<P>REMOVED SPLICE FITTING (STIFFENER), FABRICATED, AND INSTALLED NEW SPLICE (STIFFENER) P/N 7075T651. .500 BARE PLATE, PO #1904679 DIM (3.6' X 14.2") AT KEEL BEAM R/H STA 786 BULKHEAD IAW B767 DWSDR AALA2019042539011Channel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO DOOR CUTOUT LOWER SILL HAT CHANNELS (4 EA) BETWEEN FR 24 AND FR 27. REPLACED HAT CHANNELS (4 EA) PER SRM 51-75-16 AND 51-41-01.SDR AALA2019042539012Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD INBOARD FLOOR FITTING HAS CORROSION AT MAIN CABIN FORWARD LEFT HAND STOWAGE UNIT. REPLACED FLOOR FITTING PER AARD 25-31-00-02 REPAIR 2.5.SDR IPXA201904241364Support Bracket · crackedINSPECTION TYPE:12YRAFT CARGO COMPARTMENT FWD BULKHEAD UPPER PANEL SUPPORT BRACKET FR54 @ RBL 77 CRACKEDREMOVED AND REPLACED NEW UPPER BRACKET IAW A300-600 UPS 51-40-21SDR IPXA201904241363Support Bracket · crackedINSPECTION TYPE:12YRAFT CARGO COMPARTMENT FWD BULKHEAD UPPER PANEL SUPPORT BRACKET FR54 @ LBL 77REMOVED AND REPLACED NEW UPPER BRACKET IAW A300-600. UPS 51-40-21SDR AALA201904242007Baffle · crackedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO COMPARTMENT LEFT HAND BAFFLE BETWEEN BS 500E AND BS 500F CRACKED. REPLACED BAFFLE PER AARD51-00-05-1 AND AARD 53-00-01-6.SDR AALA201904242006Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: FORWARD WET AREA FLOOR INTERCOSTAL CRACKED BETWEEN BS 344 AND BS 360 AT LBL 10. REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA201904242005Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR SUPPORT CRACKED AT BS 540 AND LBL 1. REPLACED FLOOR SUPPORT PER AARD 51-00-05-1.SDR AALA201904242004Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR SUPPORT CRACKED AT BS 540 AND RBL 1. REPLACED FLOOR SUPPORT PER AARD 51-00-05-1.SDR R61A201904220403Floor Support · corrodedDURING HEAVY CHECK VISIT FOUND CORROSION ON AFT WET AREA INTERCOSTAL BETWEEN FR89 AND FR90. REMOVED AND REPLACED INTERCOSTAL AT AFT WET AREA FR89-90 REF. SRM 51-40-08. RESTORED SURFACE PROTECTION REF. EMB SRM 51-23-06. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLSDR R61A201904220402Floor Support · corrodedDURING HEAVY CHECK VISIT FOUND CORROSION ON AFT WET AREA INTERCOSTAL BETWEEN FR90 AND FR91. REMOVED AND REPLACED INTERCOSTAL AT AFT WET AREA FR90-91 REF. SRM 51-40-08. RESTORED SURFACE PROTECTION REF. EMB SRM 51-23-06. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLSDR R61A201904220401Floor Splice · corrodedDURING HEAVY CHECK VISIT FOUND CORROSION ON AFT WET AREA FLOOR SPLICE AT FR89 Y=+10.748. REMOVED AND REPLACED SPLICE AT AFT WET AREA FR89 REF. SRM 51-40-08.RESTORED SURFACE PROTECTION REF. EMB SRM 51-23-06. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.SDR R61A201904220400Splice · corrodedDURING HEAVY CHECK VISIT FOUND CORROSION ON AFT WET AREA FLOOR SPLICE AT FR90 Y= +10.748. REMOVED AND REPLACED AFT WET AREA FLOOR SPLICE AT FR90 Y= +10.748. RESTORED SURFACE PROTECTION REF. EMB SRM 51-23-05, 51-23-06. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETSDR SWAA2022030749406Stiffener · crackedRT FLOOR SUPPORT STIFFNER AT APPROXIMATELY F.S.540 (CENTER AISLE) CRAKED. / REMOVED AND REPLACED RT FLOOR SUPPORT STIFFNER AT APPROXIMATLY F.S 540 (CENTER AISLE) PER SRM 51-40-02SDR SWAA2019052332928Support · corrodedFORWARD CARGO BAY L/H FLOOR-TO-SIDEWALL SUPPORT CORRODED BETWEEN BS. 440 TO BS. 480, LBL 24. INSTALLED SUPPORT PER SRM AND DWG.SDR SWIA2019051745896Support Angle · corrodedPAX DOOR SILL LOWER FLOOR SUPPORT ANGLE CORREDED. (C-CHECK) RO: 05/16/2019 REMOVED AND INSTALLED NEW PAX DOOR SILL LOWER FLOOR SUPPORT ANGLE ASSY. P/N: 601R31527-221 IAW SRM.SDR SWAA2019051632734Intercostal · corrodedFORWARD CARGO BAY INTERCOSTAL CORRODED BETWEEN BS. 500 TO BS. 500A, RBL 6. R&R INTERCOSTAL PER SRM AND DWG.SDR REXA2019042100595Support · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORT IN STA. FS= 339 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX) SUMMARY: LEVEL CORROSION 2.PROTECTION PLATE SUPPORT IN STA. FS= 339 BETWESDR ASAA2019042129224Intercostal · crackedFWD WET AREA FLOOR INTERCOSTAL BETWEEN STA 312 AND 328 LBL 45 IS CRACKED. GROUNDED - YES. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51 40 02 0G 0.SDR ASAA2019042129206Intercostal · crackedFWD WET AREA INTERCOSTAL BETWEEN STA 328 AND 344 LBL 45 IS CRACK. GROUNDED - YES. REMOVED AND REPLACED FWD WET AREA INTERCOSTAL BETWEEN STA 328 AND 344 LBL 45 IAW SRM 51 40 02 0G 0 PARA 9.B.SDR SWAA2019050132177Fitting · crackedAFT OF FRAME INTERCOSTAL CLIP CRACKED AT BS. 500B, LBL 20. R&R CLIP PER SRM AND DWG.SDR REXA2019042610507Intercostal · corrodedCORROSION ON INTERCOSTAL BTW STA FS:349 TO FS:364 AND BTW STGR 27 AND 26RH AT MAIN AVIONICS COMPARTMENT. INTERCOSTAL BTW STA FS:364 AND BTW STGR 27 AND 26 RH AT MAIN AVIONICS COMPARTMENT (E/E) WAS REPLACED PER CRJ 900 SRM 53-21-23-101-001-A02, 51-42-06-001-0SDR AALA2019042329026Floor Support · brokenAIRCRAFT IN BASE MAINTENANCE: FLOOR SUPPORT UNDER FLOOR PANEL 231VF IS BROKEN. REPLACED FLOOR SUPPORT PER SRM 51-42-11.SDR SWAA2022030745889Strip · corrodedAFT CARGO COMPARTMENT BETWEEN STA 792 AND 787 RBL 20 UNDER CARGO DOOR FLOOR STRAP NUT PLATE STRIP IS CORRODED ON BOTTOM SIDE AS MARKED / REMOVED AND REPLACED NUT PLATE STRIP IN AFT CARGO BETWEEN STA 787-792 RBL 20 IAW SRM 51-40-02-0G-0 AND BOEING DWG 146A0081 SDR SWAA2022030745892Strip · corrodedAFT CARGO COMPARTMENT AT STA 767 +5' BETWEEN RBL 19 AND LBL 19 FLOOR PNL TRANSITION NUT PLATE STRIP IS CORRODED IN SEVERAL AREAS ON BOTH SIDES AS MARKED / REMOVED CORROSION @ AFT CARGO; F.S. 767+5 BETWEEN RBL-19 & LBL-19; FLOOR PANEL TRANSITION NUTPLATE STRIP.SDR SWAA2022030745887Strip · corrodedAFT CARGO COMPARTMENT AT STA 887 BETWEEN RBL 20 AND LBL 9 FLOOR TRANSITION NUTPLATE STRIP IS CORRODED IN SEVERAL AREAS TOP AND BOTTOM SURFACE / REMOVED DAMAGE; NO SRM LIMITS GIVEN REPALCED IAW B737-700 SRM 51-10-02-0G-0; DWG 146A 7500 REV: B; SRM 51-40-02-0G-0SDR SWAA2022030745882Angle · corrodedAFT CARGO BAY AT STA 947.5 BETWEEN LBL 10 AND RBL 20 AFT BULKHEAD PNL LOWER SUPPORT L ANGLE HAS CORROSION ON THE TOP AND BOTTOM SURFACES IN SEVERAL AREAS / BLENDED CORROSION VERIFIED MATERIAL LOSS ORG 'T' 100 REM 'T' .060 LOSS .040 FOUND TO BE OUT OF LIMITS IASDR SWAA2022030746763Strip · corroded***CORROSION*** AFT CARGO TRANSITION STRIP BS 887; RBL 16- LBL 4; WL 168 / REMOVED AND REPLACED AFT CARGO TRANSITION STRIP AT BS887 RBL16 TO LBL 4 WL 168 PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; BOEING DWG 146A7500 RWB SRM 51-10-02-G0-0 CORRODED OUT OF LIMITSSDR SWAA2022030746764Support · corroded***CORROSION*** AFT CARGO FLOOR SUPPORT BS 944; RBL 3; WL 180 / REMOVED AND REPLACED AFT CARGO FLOOR SUPPORT CHANNEL AT BS 887 TO BS944; RBL 3; WL180 IAW SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 AND BOEING DWG #147A7501 AND SRM 20-44-04SDR SWAA2019061233579Angle · corrodedAFT CARGO COMPARTMENT L/H Z ANGLE CORRODED BETWEEN BS. 727C TO BS. 847. R & R L/H ZEE ANGLE IAW SRM.SDR WVER2019052121Angle · corrodedPAX DOOR SILL ANGLE CORRODED FS 310.0 TO FS 349.0, FWD, MID, AND AFT SECTIONS.SDR SWAA2019051432657Angle · corrodedFORWARD CARGO ZEE ANGLE CORRODED BETWEEN CORRODED BETWEEN BS. 400 TO BS. 500D, LBL 24. R&R SIDE PLATE Z IAW SRM AND DWG.SDR SWAA2019051432656Angle · corrodedFORWARD CARGO ZEE ANGLE CORRODED BETWEEN BS. 500A TO BS. 500D, RBL 24. R&R SIDE PLATE Z IAW SRM AND DWG.SDR SWAA2019051432655Channel · corrodedAFT CARGO Z-CHANNEL CORRODED AT BS. 893, RBL 21. R&R Z-CHANNEL IAW SRM AND DWG.SDR SWAA2019051432654Floor Support · corrodedAFT CARGO FLOOR SUPPORT CORRODED AT BS. 944, RBL 8. R&R AFT CARGO FLOOR SUPPORT IAW SRM AND DWG.SDR SWAA2019051432627Angle · corrodedAFT CARGO Z-CHANNEL CORRODED BETWEEN BS. 727 TO BS. 849, LBL 21. R&R ANGLE IAW SRM AND DWG.SDR REXA2019042000660Fitting · gougedMAIN AVIONICS COMPARTMENT DOOR FWD LH FITTING ON FUSELAGE IS GOUGED. BLENDED DAMAGE IAW SRM 51-12-00 TR 51-44 NO ALLOWABLE DAMAGE LIMITS IAW SRM 53-21-23 REMOVED AND REPLACED FITTING IAW SRM 51-41-04 601R-38343-1 B94305.SDR REXA2019042000611Door Sill · crackedWHILE WORKING AFT CARGO LT FLOOR SILL LBL 36 FOUND CRACK IN FLOOR SILL FS 589. REPAIRED AFT CARGO AT FLOOR SILL LBL 36 & FS 589 IAW REO 601R-53-61-433.SDR SWAA2019050332244Shield · corrodedAFT CARGO COMPARTMENT AFT FLOOR SHIELD CORRODED BETWEEN BS. 867 TO BS. 847. R&R SHIELD IAW DWG AND EA.SDR SWAA2019050332132Channel · corrodedAFT CARGO Z-CHANNEL CORRODED BETWEEN BS. 727 TO BS. 767, RBL 21. R&R Z-CHANNEL IAW SRM AND DWG.SDR SWAA2019050332131Shield · corrodedAFT CARGO FORWARD SHIELD CORRODED BETWEEN BS. 767 TO BS. 794, RBL 21. R&R SHIELD IAW SRM AND DWG.
Back to JASC 5320