SDR FDEA201902190454Floor Support · corrodedMAIN DECK FLOOR SUPPORT ASSY AT STA 615 BETWEEN RBL 48 AND RBL 75, HAS HEAVY CORROSION THRU OUT ASSY. REMOVED AND REPLACED FLOOR SUPPORT ASSY REF SRM 51-31-01. DAC DWG ACA7664.SDR SWAA2022030266330Bracket · crackedAFT CARGO BAY VERTICAL BULKHEAD STATION AT BS 947 LBL 12 IS CRACKED / NO ALLOWABLE DAMAGE FOUND IN SRM; REMOVED AND REPLACED AFT CARGO BAY VERTICAL BULKHEAD BRACKET AT B.S. 947 LBL 12 IAW SOPM 20-50-01 AND BOEING DRAWING 149A8118 SH 14 AND IPC 53-11-51-01 9281SDR SWAA2022030266924Splice · corrodedAFT CARGO FLOOR BOARD T SPLICE AT BS 767 + 6' LBL 4' TO 10' CORRODED. / PART VERIFIED AS P/N:146A9401-4 FOR NEW T-SPLICE IAW B737-700 DRWG #:146A7500 REV. T -4 T.SPLICE & FLOOR BOARD TO BE INSTALLED ON JPANEL 141-CLOSE CARD W/O #:38953/1600/0006.SDR SWAA2022030266926Splice · corrodedAFT CARGO FLOOR BOARD SPLICE T CORRODED BS 887 RBL 10' TO RBL 20'. / PART VERIFIED AS P/N:140A7401-37 FOR NEW T. SPLICE IAW B737-700 DRWG #; A46A7500 REV 6 - 39 T.SPLICE & FLOOR BOARD TO BE INSTALLED ON JPANEL - 141-CLOSE CARD W/0 #:38953/1600/0006SDR SWAA2022030282285Strap · corrodedAFT CARGO COMPARTMENT STA 947 FLOOR STRAP CORRODED / REMOVED AND REPLACED AFT CARGO COMPARTMENT STA 947 FLOOR STRAP PER AMM 25-52-10SDR SWAA2022030245469Angle · corrodedFWD CARGO COMPARTMENT AT STA. 500I; LBL 25 TO RBL 25; FLOOR ANGLE HAVE SEVERAL AREAS OF CORROSION. / NO ALLOWABLE LIMITS. REMOVED DAMAGED ANGLE INSTALLED NEW ANGLE AS REQUIRED. FWD CARGO STA 500I LBL25-RBL25. IAW BOEING DWG: 143A9481 REV:-. SRM 51-40-02-0G-0SDR SWAA2022030245467Angle · corrodedFWD CARGO COMPARTMET; STA. 500C+11 - 500F; R/H Z-ANGLE HAVE SEVERAL AREAS OF CORROSION. / REMOVED AND REPLACED FWD CARGO R/H Z ANGLE STA 500A-500F + 12' IAW B737 SRM 51-10-02-0G-0; SRM 53-00-53-2R-5. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG 103 DETASDR SIMA20190218008Beam · corrodedRT INBD LONGITUDINAL BEAM HAS CORROSION AT CROSSBEAM FS1031.00. C/A-C/W REPAIR OF RT I/B LONGITUDINAL BEAM IAW SRM 53-00-41.SDR SIMA20190218006Bracket · corrodedFRAME 68 CARGO DOOR CUTOUT LOWER SILL T BRACKET CORRODED. C/A-REMOVED AND REPLACED FRAME 68 CARGO DOOR CUTOUT LOWER SILL T BRACKET IAW SRM 51-40-02.SDR SIMA20190218007Fitting · corrodedFRAME 65 SHEAR CLIP CORRODED AT CARGO DOOR LOWER SILL. C/A-REPAIRED FRAME 65 SHEAR CLIP IAW SRM 53-31-04.SDR REXA2019021800246Fitting · corrodedLBL 9 O/B FLOOR PANEL LANDING HAS CORROSION SPOT BETWEEN FS 605 AND FS 621, IN THE CARGO BAY. REPAIRED FLOOR PANEL LANDING IAW EA #CRJ253-08402.SDR SWAA2019030630235Support · corrodedAFT CARGO BAY ON RT FLOOR TO SIDEWALL SUPPORT CORRODED BETWEEN BS 727 TO BS 767, RBL 22. R&R SUPPORT PER SRM AND DWG.SDR R61A201902180231Angle · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORRODED 3 EA LOWER ANGLES AND 4 CRACK RECEPTACLE ON PANEL 1441FR. REMOVED AND REPLACED 3 EA LOWER ANGLES ON PANEL 1441FR, REF AMM 20-10-01, SRM 51-40-08. A/C REMAINS IN CHECK.SDR R61A201902180230Angle · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORRODED 3 EA LOWER ANGLES AND 2 CRACK RECEPTACLE ON PANEL 1431DL. REMOVED AND REPLACED 3EA. LOWER ANGLES ON SIDE OF PANEL 1431DL REF: SRM 51-40-08. AMM 20-10-07/200. A/C REMAINS IN CHECK.SDR R61A201902180229Threshold · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AT FWD AND AFT GIRT BAR FITTING CUTOUT EDGE AND LOWER BOTTOM ON THRESHOLD. REMOVED AND REPLACED L1 DOOR THRESHOLD BEAM. REF SRM 51-40-08. A/C REMAINS IN CHECK.SDR SWAA2019022830142Angle · corrodedAFT CARGO RT Z ANGLE CORRODED BETWEEN BS 727C+10 TO BS 767, RBL 22. REPAIRED Z ANGLE IAW SRM AND DWG.SDR A6WA2019022746423Door Sill · corrodedSERVICE DOOR LOWER SILL ANGLE HAS CORROSION. REPLACEDSDR A6WA2019022746422Floor Support · corrodedLBL 27 FLOOR BEAM CAP BETWEEN FS 589 AND FS 605 IS CORRODED. REPLACEDSDR IPXA2019022769454Stiffener · crackedINSPECTION TYPE:C12CRACK ON THE CENTER WING FRONT SPAR STIFFENER (P/N : 111T2005-7) UPPER SIDE AT STA 785.9 , LBL 11REPAIR I.A.W 767-300F SRM 57-10-10-2R-2 REPAIR 2 REV.73.01 AND UPS EO B767-5740-58151-ASDR IPXA2019022769453Stiffener · crackedINSPECTION TYPE:C12CRACK ON THE CENTER WING FRONT SPAR STIFFENER (P/N : 111T2008-11) UPPER SIDE AT STA 785.9 , LBL 33REPAIR I.A.W 767-300F SRM 57-10-10-2R-2 REPAIR 2 REV.73.01 AND UPS EO B767-5740-58151-ASDR AALA20190219007Floor Support · crackedCRACKED FORWARD WET AREA FLOOR SUPPORT BETWEEN BS 277 AND 294, BL 0. REPLACED THE FLOOR SUPPORT IAW RD 51-00-05-1.SDR DALA2019022281118Structure · corrodedCORROSION LOWER SILL AT LEVEL STR23R AT AFT GALLEY AREA, REPLACED LOWER SILL AT LEVEL STR 23R AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 AND DWG D53480505SDR SWAA2019022129903Angle · corrodedFORWARD CARGO COMPARTMENT RT Z-ANGLE CORRODED BETWEEN BS 500C+11 TO BS 500F. R&R Z ANGLE IAW SRM.SDR VNAA2019022099907Support Plate · corrodedFLOOR STRUCTURE BETWEEN FS 310 AND FS 319.70 GALLEY AFT IB MAINT LOCATION HAS CORROSION AROUND FASTENER HOLE. REMOVED PLATE. FABRICATED REPLACEMENT PLATE IAW CRJ 200 SRM 51-24-36, 51-40-11 & 51-40-06 REFERENCING DRAWING #601R387781 FOR MATERIAL TYPE, THICKNESSDR VNAA2019022099906Angle · crackedFS 484 LBL 36 CLIP IS CRACKED, APPEARS TO BE PREVIOUS REPAIR ANGLE. REMOVED PREVIOUS REPAIR CLIP. FABRICATED REPLACEMENT CLIP IAW CRJ 200 SRM 51-24-36, 51-40-11 & 51-40-06 REFERENCING BOMBARDIER REO 601R-53-41-059 REV B FOR MATERIAL TYPE, THICKNESS & FASTENERSDR VNAA2019022099905Floor Support · corrodedLBL 27 FLOORBEAM IS CORRODED AROUND MULTIPLE FASTENER HOLES BETWEEN F.S. 574 - F.S 605. REMOVED UNSERVICEABLE LBL 27 FLOORBEAM BETWEEN F.S. 574 - F.S. 605 THAT WAS CORRODED AND INSTALLED A SERVICEABLE FLOORBEAM AT LBL 27 BETWEEN F.S. 574 - F.S. 605 IAW CRJ 20SDR IPXA2019022099189Support Bracket · crackedINSPECTION TYPE:1CAFT CARGO COMPARTMENT FWD BULKHEAD UPPER PANEL SUPPORT BRACKET FR54 @ LBL36REMOVED AND REPLACED NEW SUPPORT BRACKET IAW A300-600 UPS SRM 51-40-21SDR AALA201902208002Web · corrodedCORROSION FOUND ON THE AFT CARGO DOOR CUT OUT THRESHOLD WEB BETWEEN BS 807 AND 847, STRINGER 25R. REPLACED THE THRESHOLD WEB IAW SRM 51-40-02, AND 51-20-01-OG.SDR DALA2019021901027Cusp Web · corrodedEXCESSIVE CORROSION AT CUSP WEB BETWEEN STA 541/560 X=-65 IN REF NRC 00299. NRC 00549: CORROSION LEVEL 2, CUSP WEB BETWEEN STA 541/560 X=-65 WAS REPAIRED PER B717-200 SRM 53-00-55-2R REPAIR 4 FIG. 215 TABLE 2. (ET) HFEC INSP WAS ACCOMPLISHED ON CUSP WEB BETWEESDR DALA2019021901024Floor Support · corrodedCORROSION ON FLOOR SUPPORT BTW STA Y=180 AND Y=200 AND X=-44 AT FWD WET AREA (IN REF. AMDS 5300-2010)(W1). NRC 00372: CORROSION LEVEL 2, FLOOR SUPPORT BTW STA Y=180 AND Y=200 AND X=-44 WAS REPLACED PER B-717-200 SRM 51-41-02-0G AND SRM 51-41-05-0G. (LP #094997SDR DALA2019021901023Threshold · corrodedCORROSION FOUND AT AFT CARGO DOOR THRESHOLD. REPLACED AFT CARGO DOOR JAMB REF SRM 53-20-15-2R PROC 7.SDR SWAA2022030217924Scuff Plate · crackedAFT CARGO COMPT AFT CORNER SCUFFPLATE CRACKED / REMOVED AND REPLACED AFT CARGO DOOR COMPARTMENT AFT LOWER CORNER SCUFF PLATE P/N 654A0004-169 PER SRM 51-40-02 AND SRM 51-40-05.SDR SWAA2022030243321Doubler · crackedWHILE CONNECTING GROUND POWER NOTICED A CRACK AROUND THE FWD RIVET AT THE BOTTOM INITIAL RUBBING BLOCK ON THE EGPR DOUBLER AT THE EXTERNAL POWER RECEPTACLE. THERE IS ALSO A GAP BETWEEN THE EGPR SURROUND DOUBLER AND EGPR STIFFENER / REPAIRED EXTERNAL GROUND POWSDR SWIA201904035726Door Sill · corrodedCARGO SILL CORRODED FROM FS 574.0 TO FS 621. (C-CHECK) RO: 04/01/2019 REPLACED CARGO DOOR SILL FROM FS 574.0 TO FS 621 IAW REO.SDR COEA2019021702912Floor Support · crackedWO 194688 NR 100019 HEAVY CHECK COE/MAJOR REPAIR: LT OUTBOARD LONGITUDINAL FLOORBEAM CRACKED AT FRAME 19. CORRECTIVE ACTION: REPAIRED PER E.O. 5315-01.SDR COEA2019021701912Floor Support · crackedWO 194688 NR 100018 HEAVY CHECK COE/MAJOR REPAIR: LT OUTBOARD LONGITUDINAL FLOORBEAM IS CRACKED FWD AND AFT OF FRAME 22. CORRECTIVE ACTION: REPAIRED PER E.O. 5315-01.SDR SIMA20190217003Bracket · corrodedFRAME 65 CARGO DOOR CUTOUT LOWER SILL T BRACKET CORRODED. C/A-REMOVED AND REPLACED FRAME 65 CARGO DOOR CUTOUT LOWER SILL T BRACKET IAW SRM 51-40-02.SDR SIMA20190217004Door Sill · corrodedCARGO DOOR CUTOUT LOWER SILL CORRODED. C/A-REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER SILL IAW SRM 51-40-02.SDR REXA2019021700252Beam · corrodedLBL 27 I/B AND O/B FLOOR PANEL LANDINGS HAS CORROSION SPOTS BETWEEN FS 574 THRU FS 621, IN THE CARGO BAY. REPLACED LBL27, FS 574 TO FS621 BEAM CAP IAW SRM 51-42-21 & 51-42-22.SDR V0XD20190227002Support Angle · corrodedAFT WING TO BODY SUPPORT STRUCTURE "L" ANGLE IS CORRODED AT F.S. 939 AT STGR 27. CORRECTIVE ACTION REMOVED AND REPLACE "L" ANGEL(PN:SH670-39-189-1) IAW CRJ 700 SRM 51-42-06, 53-00-00, 51-21-06, 51-40-11, AND 53-82-55.SDR REXA20190225165Intercostal · corrodedINITIAL INSPECTION: CORROSION ON INTERCOSTAL BTW FS 349 AND FS 364 BTW STRNG 27-26L AT MAIN AVIONICS COMPARTMENT. (E/E). TCI: 100-09
COMPLETE: SUMMARY: CORROSION LEVEL-2, NEW INTERCOSTAL BTW FS 349 AND FS 364 BTW STRNG 27-26L AT MAIN AVIONICS COMPARTMENT. (E/SDR DALA2019021801019Floor Support · corrodedCORROSION ON FLOOR SUPPORT STA Y=180 AND 200 BTW X=-9 TO X=-43 AT FWD WET AREA (IN REF. AMDS 5300-2010)(W1). NRC 00371: CORROSION LEVEL 2, FLOOR SUPPORT STA Y=180 AND 200 BTW X=-9 TO X=-43 AT FWD WET AREA WAS REPLACED PER B717-200 SRM 51-41-02 AND SRM 51-41-05SDR SWAA2022030222065None · corrodedSUPPLEMENTAL INFORMATION: AFT CARGO R/H AFT #3 FLOOR BOARD CAP STRIP HAS CORROSION ON BOTTOM SIDE. / REMOVED AND REPLACED AFT CARGO RH AFT #3 CAP STRIP REF AMM 25-52-10.CHANGED ATA CODE TO CORROSION 53-98SDR SWAA2022030222064None · corrodedSUPPLEMENTAL INFORMATION: AFT CARGO R/H MIDDLE #2 FLOOR BOARD CAP STRIP HAS CORROSION ON BOTTOM SIDE. / REMOVED AND REPLACED AFT CARGO RH MIDDLE #2 CAP STRIP REF AMM 25-52-10.CHANGED ATA CODE TO CORROSION 53-98.SDR SWAA2022030222063None · corrodedSUPPLEMENTAL INFORMATION: AFT CARGO R/H FWD #1 FLOOR BOARD CAP STRIP HAS CORROSION ON BOTTOM SIDE. / R/R AFT CARGO R/H FWD #1 FLOOR BOARD CAP STRIP PER AMM.25-52-10SDR SWAA2022030222060Strip · corrodedAFT CARGO L/H FWD #1 FLOOR BOARD CAP STRIP HAS CORROSION ON BOTTOM SIDE. / REMOVED AND REPLACED AFT CARGO L/H FWD #1 FLOOR BOARD CAP STRIP PER AMM 25-52-10.CHANGED ATA CODE TO 53-98 CORROSIONSDR SWAA2022030222061Strip · corrodedAFT CARGO L/H MIDDLE #2 FLOOR BOARD CAP STRIP HAS CORROSION ON BOTTOM SIDE. / REMOVED AND REPLACED AFT CARGO L/H MIDDLE #2 FLOOR BOARD CAP STRIP PER AMM 25-52-10.CHANGED ATA CODE TO 53-98 CORROSIONSDR SWAA2022030222062Strip · corrodedAFT CARGO L/H AFT #3 FLOOR BOARD CAP STRIP HAS CORROSION ON BOTTOM SIDE. / REMOVED AND REPLACED AFT CARGO L/H AFT #3 FLOOR BOARD CAP STRIP PER AMM 25-52-10.CHANGED ATA CODE TO 53-98 CORROSIONSDR SWAA2022030266325Scuff Plate · crackedFWD CARGO BAY FWD CORNER SCUFF PLATE IS BROKEN IN HALF / LOCATED AND DRILLED REPLACEMENT SCUFF PLATE IN FWD CARGO BAY FWD CORNER IAW DRAWING 143A8331. INSTALLATION WILL BE PERFORMED ON CUSTOMER CARD NBR 753-140-00-01Y 80570U 18FEB19SDR SWAA2022030266326Scuff Plate · brokenFWD CARGO BAY AFT CORNER SCUFF PLATE IS BROKEN IN HALF / LOCATED AND DRILLED REPLACEMENT AFT CORNER SCUFF PLATE IN FWD CARGO BAY IAW DRAWING 143A8331. INSTALLATION WILL BE PERFORMED ON CUSTOMER CARD NBR 753-140-00-01Y 80570U 18FEB19