JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201811299003Floor Support · corrodedCORROSION WAS FOUND ON THE FLOOR SUPPORT, FRAMES 64 TO 66, IN THE AFT GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DRAWING D53472815.SDR SWAA2018112727134Gusset · crackedFORWARD CARGO COMPARTMENT GUSSET CRACKED AT BS 500D, STR 22L. R&R GUSSET IAW SRM AND DWG.SDR SWAA2018112727065Gusset · crackedFORWARD CARGO COMPARTMENT GUSSET CRACKED AT BS 500D, STR 21L. R&R GUSSET IAW SRM AND DWG.SDR DALA20181126799Floor Support · crackedSHIP 6703 CRACKED INTERCOSTAL ON CEILING AREA BL 0 BTW STA 1320 AND 1340 AT AFT CARGO COMPARTMENT (C2). CORRECTIVE ACTION: SUMMARY IN REF NRC 00135 ANGLE OF THE INTERCOSTAL AREA BL 0 BTW STA 1320 AND 1340 AT AFT CARGO COMPARTMENT (C2) WAS REPLACED PER B757-200SDR DALA201811266774Support · corrodedCORROSION LEVEL: 2 KEEL BEAM PANEL SUPPORT CORRODED - KEEL BEAM OPENING FWD EDGE AT FS 738 STR 38L - 38R. REPLACED PANEL (LP 0831322)SDR DALA2018112096723Floor Support · crackedSHIP 6703 INITIAL INSPECTION. CRACK ON INTERCOSTAL UPPER SIDE FS STA: 405 AND BL 0 AT PAX CABIN. CORRECTIVE ACTION: NRC 329: INTERCOSTAL WAS REPAIRED PER B757-200 SRM, (ET) (HFEC) INSPECTION WAS ACCOMPLISHED ON INTERCOSTAL UPPER SIDE FS STA: 405 AND BL 0 AT PASDR DALA201811206704Floor Support · cracked(LOG 0832226) DURING INSPECTION FOUND CRACK INTERCOSTAL BTW STATION 312 TO STA 328 RBL 31 AT FWD WET AREA. INTERCOSTAL BTW STATION 312 TO STA 328 RBL 31 AT FWD WET AREA WAS REPLACED PER B737-800 SRM 51-40-02.SDR AALA2018112018007Floor Support · crackedCABIN FLOOR SUPPORT BS 285, RBL 1, WAS CRACKED. REPLACED THE FLOOR SUPPORT IAW DWG 141A5400, AND RD 51-00-05.SDR FDEA2018111983283Floor Panel · delaminatedCOURIER FLOOR PANEL 222QF DELAMINATED. FABRICATED COURIER FLOOR PANEL 222QF ON VT MAE TRAVELER T18/1378236 IAW FED EX DWG SRZ-25-005. MAJOR REPAIRSDR VNAA2018111999903Angle · crackedF.S.280.00 I/B AND O/B CLIPS ARE CRACKED AT LBL9 AND RBL9. CA REPLACED CLIPSSDR VNAA2018111999902Support Angle · crackedL/H F.S.621.00 TO 625.00 OBLIQUE ANGLE IS CRACKED CA REPLACED ANGLESDR A6WA2018111946166Channel · crackedCHANNEL BETWEEN F.S.621.00 AND F.S.625.30 AT STGR 13L OUTBD OF LBL36.2 IS CRACKED.SDR R61A201811181162Crossbeam · corrodedWHILE IN HEAVY CHECK - FRAME 17 CROSSBEAM BETWEEN RT INBD SEAT TRACK AND RT FLOOR SILL CORRODED. PERFORMED DAMAGE CUT-OUT CROSS FRAME 17 REF SRM 53-00-10 FIGURE 204. INSTALLED CROSS FRAME 17 RT I/B SEAT TRACK REPAIR DOUBLER, FILLER, SHIM, GALLEY SUPPORT BRACKESDR R61A201811181161Floor Support · corrodedWHILE THE ACFT IS IN HEAVY CHECK FOUND FRAME 19 CROSSBEAM FLOOR SUPPORT AT LT FLOOR SILL CORRODED. REMOVED AND REPLACED FRAME 19-20 CROSSBEAM FLOOR SUPPORT AT LT INBD FR19-20. REF SRM 51-40-08, RESTORED SURFACE PROTECTION REF SRM 51-23-06 CPM 51-25-00. ACFT RESDR R61A201811181159Doubler · corrodedWHILE THE ACFT IS IN HEAVY CHECK - FOUND LT FLOOR DOUBLER AT FRAME 16 CORRODED. REMOVED AND INSTALLED REPLACEMENT LT FLOOR DOUBLER AT FRAME 16 REF SRM 51-40-08. APPLIED SURFACE PROTECTION TO LT FLOOR DOUBLER AT FRAME 16 REF SRM 51-23-06, CPM 51-25-00. ACFT REMSDR R61A201811181158Door Sill · corrodedWHILE THE ACFT IS IN HEAVY CHECK - FOUND LT FLOOR SILL CORRODED AT FRAME 19. REMOVED AND REPLACED LT FLOOR SILL FR19-21. REF SRM 51-40-08, RESTORED FINISH REF SRM 51-23-04, 51-23-05, 51-23-06. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.SDR R61A201811181157Doubler · corrodedWHILE THE ACFT IS IN HEAVY CHECK - FOUND LT FLOOR DOUBLER BETWEEN FRAMES 19/20 CORRODED. REMOVED AND INSTALLED OF LT FLOOR DOUBLER BETWEEN FRAMES 19/20. REF SRM 51-45-00, SRM 51-40-05. APPLIED SURFACE PROTECTION TO LT FLOOR DOUBLER BETWEEN FRAMES 19/20. REF SRSDR SWAA2022022531059Scuff Plate · crackedFWD CARGO BAY FORWARD CORNER SCUFF PLATE CRACKED (MARKED) / REPAIRED FWD CARGO BAY FWD CORNER SCUFF PLATE PER: EA 1-A53-2076 REV 11SDR SWAA2022022570255Angle · corrodedFORWARD CARGO R/H TRANSITION ANGLE HAS CORROSION FROM STA 500A TO STA 500D / REMOVED AND REPLACED FORWARD CARGO R/H TRANSITION ANGLE FROM STA 500A TO STA 500D PER SRM 51-40-02SDR SWIA2018121245368Door Sill · corrodedTHE SERVICE DOOR FWD SILL FROM FS310.0 TO FS319.0 HAS CORROSION. (C-CHECK) RO: 12/11/2018 REMOVED AND REPLACED FLOOR SILL IAW SRM.SDR FDEA2018111973268Floor Support · corrodedMAIN DECK CARGO COMPARTMENT AFT FLOOR PANEL SUPPORT FOUND WITH CORROSION AT STATION 1897 X = 58. MAIN DECK CARGO AFT FLOOR PANEL SUPPORT AT STATION 1897, X = 58. CORROSION REMOVED AND FOUND EXCEEDED LIMIT AS PER SRM 53-00-00-2R, FIGURE 206. FLOOR PANEL SDR SWAA2018111926929Angle · corrodedFORWARD CARGO FLOOR STRUCTURE L ANGLE CORRODED AT BS 500D, BETWEEN LBL 24 TO RBL 24. REPAIRED L ANGLE PER SRM.SDR SWAA2018111926878Scuff Plate · crackedR1 DOOR LOWER SILL SCUFF PLATE CRACKED. REPAIRED SCUFF PLATE IAW EA.SDR AALA201811197012Floor Support · crackedA CRACK INDICATION WAS FOUND ON THE FLOOR SUPPORT, BS 328 - 344, LBL 45. REPLACED THE FLOOR SUPPORT IAW DRAWING 141A5400, AND RD 51-00-05-1.SDR AALA201811197011Floor Support · crackedA CRACK INDICATION WAS FOUND ON THE FLOOR SUPPORT, BS 312 - 328, LBL 45. REPLACED THE FLOOR SUPPORT IAW DRAWING 141A5400, AND RD 51-00-05-1.SDR AALA201811197009Floor Support · crackedCRACK INDICATION FOUND ON THE FLOOR SUPPORT BETWEEN BS 312-328, RBL 31-32. REPLACED THE FLOOR SUPPORT IAW RD 51-00-05-1,PRINT 141A5410, AND DRAWING 141A5400.SDR AALA201811197008Floor Support · crackedA CRACK INDICATION WAS FOUND ON THE FLOOR SUPPORT BETWEEN BS 328 - 344, LBL 45. REPLACED THE FLOOR SUPPORT IAW RD 51-00-05-1, AND PRINT 141A5410, AND DRAWING 141A5400.SDR AALA201811197005Floor Support · crackedCRACK INDICATION FOUND ON THE FLOOR SUPPORT BETWEEN BS 312 - 328, LBL 45. REPLACED THE FLOOR SUPPORT IAW RD 51-00-05-1, PRINT 141A5410S, AND DRAWING 141A540.SDR R61A201811171156Door Sill · corrodedWHILE THE ACFT IS IN HEAVY CHECK - FOUND RT FLOOR SILL CORRODED AS/MARKED BETWEEN FRAMES 19/20. REMOVED AND REPLACED RT FLOOR SILL BETWEEN FRAMES 17-21 REF SRM 51-40-08. APPLIED SURFACE PROTECTION TO RT FLOOR SILL BETWEEN FRAMES 17-21 REF SRM 51-23-06, CPM 51-SDR R61A201811171155Door Sill · corrodedWHILE THE ACFT IS IN HEAVY CHECK - FOUND RT FLOOR SILL BETWEEN FRAMES 12/14 CORRODED. REMOVED AND REPLACED RT FLOOR SILL BETWEEN FRAMES 12/14 REF SRM 51-40-08 AND 51-45-00. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.SDR R61A201811171154Panel Support · corrodedWHILE THE ACFT WAS IN HEAVY CHECK - FOUND CORROSION ON LT FLOOR SILL/PANEL SUPPORT FR 88-90. REMOVED AND REPLACED LT FLOOR SILL/PANEL SUPPORT FR 88-90 PER SRM 51-40-08. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.SDR R61A201811171153Gusset · corrodedWHILE THE ACFT IS IN HEAVY CHECK FOUND- CORROSION ON GUSSET PLATE AT FR 90. REMOVED AND REPLACED GUSSET PLATE AT FR 90 PER SRM 51-40-08. ACFT REMAINS IN HEAVY CHECK UNTIL COMPLETION.SDR R61A201811171152Panel Support · corrodedWHILE THE ACFT IS IN HEAVY CHECK - FOUND CORROSION ON PANEL SUPPORT AT FR 87 FWD OF RT SHEAR PANEL. REMOVED AND REPLACED PANEL SUPPORT AT FR 87 FWD OF RT SHEAR PANEL PER SRM 51-40-08. RESTORED FINISH REF SRM 51-23-04, 51-23-05, 51-23-06. ACFT REMAINS IN HEAVYSDR SWIA2019010845418Door Sill · corrodedSERVICE DOOR LOWER SILL ANGLE HAS CORROSION. (C-CHECK) RO: 01/05/2019 REMOVED AND REPLACED SERVICE DOOR LOWER SILL ANGLE IAW SRM. OP CHECKS GOOD.SDR SWIA2018113045312Door Sill · corrodedCORROSION ON SERVICE DOOR SILL FLOOR PROTECTOR PLATE AROUND UPPER FASTENER HOLES. (C-CHECK) RO: 11/29/2018. REPLACED SERVICE DOOR FLOOR PROTECTOR PLATE REF SRM 51-40-11.SDR JJBA2018113016018Floor Support · corrodedCORROSION FOUND BETWEEN FR21 TO FR22 ON RH IB CENTER OMEGA BEAM GUSSET. REMOVED AND REPLACED RH IB CTR OMEGA BEAM GUSSET FR21-22.SDR JJBA2018113016017Support · corrodedCORROSION IN L/H O/B SILL FR.43. REMOVED AND REPLACED L/H O/B SILL FR.43.SDR JJBA2018113016016Support · corrodedCORROSION IN R/H O/B SILL BETWEEN FR.39-41. REMOVED AND REPLACED R/H O/B SILL BETWEEN FR.39-41.SDR JJBA2018113016015Floor Support · corrodedCORROSION IN R/H O/B SILL FROM FR.41-48. REMOVED AND REPLACED RH OB SILL AT FR41-48.SDR FDEA201811163341Intercostal · damagedINTERCOSTAL DAMAGED BSTA 1055, RBL0-RBL26. REPAIRED DAMAGED INTERCOSTAL IAW SRM 51-70-12-REV 125 AND EAF-5340-T0343588 PART(1).SDR KCSA201811161318Intercostal · corrodedFWD PIT TORQUE BOX INTERCOSTAL HAS EVIDENCE OF CORROSION @ STA 610 RBL 27SDR AALA201811216003Strap · corrodedCORROSION FOUND ON THE RIGHT HALF MOON PANEL, OUTBOARD STRAP. REPLACED STRAP IAW RD 51-00-05-1, AND DRAWING 147A5700.SDR DALA2018112076720Floor Support · crackedSHIP 6703 INITIAL INSPECTION: CRACK ON STRINGER RBL 16.10 AND STA 678 ALSO MISSING FASTENERS ON STRINGER SUPPORT AT FWD CARGO COMPARTMENT (C1). CORRECTIVE ACTION: IN REFERENCE NRC S/N 00261 STRINGER RBL 16.10 AND STA 678 WAS REPLACED PER B757-200 SRM. (0830036SDR DALA201811206703Floor Support · corroded(LOG 0829379) DURING INSPECTION FOUND CORROSION ON FLOOR STRUCTURE SUPPORT AT AFT CARGO COMPARTMENT BTW RBL-21 AND LBL-8.10, STATION 887. CORROSION LEVEL 2.- FLOOR STRUCTURE SUPPORT AT AFTER CARGO COMPARTMENT BTW RBL-21 AND LBL-8.1, STA-887 WAS REPLACED PER B7SDR AALA201811196004Web · corrodedCORROSION FOUND ON THE RIGHT WEB AND SUPPORT CHANNEL AT BS 986.5 - 1016. REPLACED THE WEB AND SUPPORT CHANNEL IAW SRM 51-40-02, AND DRAWING 147A5712.SDR AALA201811196002Angle · corrodedCORROSION FOUND ON THE RIGHT ZEE ANGLE AT BS 992, RBL 33-48. REPLACED THE ANGLE IAW 51-00-05-1, DRAWING 147A5700, AND SRM 51-40-02.SDR AALA201811196001Angle · corrodedCORROSION FOUND ON THE RIGHT ZEE ANGLE, BETWEEN AT BS 922 - 1015, RBL 32. REPLACED Z ANGLE PER AARD 51-00-05-1, BOEING DRAWING 147A5700 AND SRM 51-40-02.SDR CALA2018111602388Intercostal · crackedR1 DOOR CUTOUT FR16 DOOR STOP FITTING NR 7 INBD LOWER HOLE HAS A CRACK INDICATION IN INTERCOSTAL AT 8 O''CLOCK POSITION REF 9290332 SPEC A3NB-53-4-6304 AD 2017-22-03. REAMED DISCREPANT HOLE AT R1 DOOR FR 16 STOP FITTING NR 7 TO REMOVE INDICATON IAW ECRA 5311-0SDR KCSA201811161321Intercostal · corrodedCORROSION ON INTERCOSTAL FWD PIT STA 510 RBL 4.SDR KCSA201811161320Stiffener · corrodedEVIDENCE OF CORROSION ON STIFFENER AT STA 1809.5 RBL 10.
Back to JASC 5320