What was found
CORROSION WAS FOUND ON THE FLOOR SUPPORT, FRAMES 64 TO 66, IN THE AFT GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DRAWING D53472815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION WAS FOUND ON THE FLOOR SUPPORT, FRAMES 64 TO 66, IN THE AFT GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DRAWING D53472815.