JASC 5320
Service difficulty reports · 216,159
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWI2024F01090Floor Support · corrodedMULTIPLE SPOTS OF CORROSION NOTED ON R/H FLOOR BEAM CAP AT LBR 9 AT APPROX. FS485.40 TO FS565.00 (MARKED) (C-CHECK RO 10/7/2024) (FILED CLOSED)REPAIRED FLOOR BEAM CAP AT RBL 9.0 BETWEEN F/S 476.55 TO F/S 571 IAW CRJ 700 SRM 53-00-41-201-001-A01 AND REO 670-53-SDR SWI2024F01089Floor Support · corrodedMULTIPLE SPOTS OF CORROSION NOTED ON R/H FLOOR BEAM CAP AT RBL 9 AT APPROX. FS565.40 TO FS677.00 (MARKED) (C-CHECK RO 10/7/2024) (FILED CLOSED)INSTALLED NEW FLOOR BEAM FROM RBL 9 FS 565 TO FS 677. REF CRJ700 SRM 53-00-41-201-001-A01 , REO 670-53-31-913 REV-A DSDR SWI2024F01088Floor Support · corrodedR/H FLOOR SILL BETWEEN FS677.00 TO FS693.00 HAS CORROSION (MARKED) (C-CHECK RO 10/7/2024) (FILED CLOSED)REMOVED AND REPLACED WITH NEW R/H FLOOR SILL BETWEEN FS677.00 TO FS693.00 REF CRJ 700 SRM 51-42-06-001-001-A01 AND DWG SH670-32170 REV V. COMPLIED WITH SKSDR SWI2024F01087Floor Support · corrodedMULTIPLE SPOTS OF CORROSION NOTED ON L/H FLOOR BEAM CAP AT LBL 9 AT APPROX. FS477.40 TO FS565.00 (MARKED) (C-CHECK RO 10/7/2024) (FILED CLOSED)REPAIRED L/H FLOOR BEAM CAP AT LBL 9 AT APPROX. FS477.40 TO FS565.00 IAW CRJ-700 SRM 53-00-41-201-001-A01 REV. 38 DASDR SWI2024F01093Floor Support · corrodedMULTIPLE SPOTS OF CORROSION ON T-CAP AT RBL9 AT APPROXIMATELY FS855.00 - FS960.00 AS MARKED (C-CHECK RO 10/7/2024) (FILED CLOSED)REPAIRED FLOOR BEAM AT RBL 9.0 FROM F/S 854.45 TO F/S 977.00 IAW CRJ 700 SRM 53-00-41-201-001-A01 AND REO 670-53-51-298 REV. -- DATSDR SWI2024F01092Floor Support · corrodedMULTIPLE SPOTS OF CORROSION ON T-CAP AT LBL9 AT APPROXIMATELY FS855.00 - FS977.00 AS MARKED (C-CHECK RO 10/7/2024) (FILED CLOSED)PERFORMED A BEAM REPAIR FROM FS855.00 TO FS904.00 PER CRJ 700 SRM 53-00-41-201-001-A01 AND REO# 670-53-51-301 REV:-- DATE:2024-08-1SDR SWI2024F00936Floor Support · corrodedMULTIPLE SPOTS OF CORROSION NOTED ON R/H FLOOR BEAM CAP AT LBR 9 AT APPROX. FS485.40 TO FS565.00 (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)REPAIRED FLOOR BEAM CAP AT RBL 9.0 BETWEEN F/S 476.55 TO F/S 571 IAW CRJ 700 SRM 53-00-41-201-001-A01 AND REO 670-53-31SDR SWI2024F00935Floor Support · corrodedMULTIPLE SPOTS OF CORROSION NOTED ON R/H FLOOR BEAM CAP AT RBL 9 AT APPROX. FS565.40 TO FS677.00 (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)INSTALLED NEW FLOOR BEAM FROM RBL 9 FS 565 TO FS 677. REF CRJ700 SRM 53-00-41-201-001-A01 , REO 670-53-31-913 REV-A DATSDR SWI2024F00934Floor Support · corrodedR/H FLOOR SILL BETWEEN FS677.00 TO FS693.00 HAS CORROSION (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)REMOVED AND REPLACED WITH NEW R/H FLOOR SILL BETWEEN FS677.00 TO FS693.00 REF CRJ 700 SRM 51-42-06-001-001-A01 AND DWG SH670-32170 REV V. COMPLIED WITH SKYWSDR SWI2024F00933Floor Support · corrodedMULTIPLE SPOTS OF CORROSION NOTED ON L/H FLOOR BEAM CAP AT LBL 9 AT APPROX. FS477.40 TO FS565.00 (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)REPAIRED L/H FLOOR BEAM CAP AT LBL 9 AT APPROX. FS477.40 TO FS565.00 IAW CRJ-700 SRM 53-00-41-201-001-A01 REV. 38 DATESDR SWI2024F00932Fitting · corrodedGALLEY 1 STRUCTURE MOUNT BOLT FITTING FWD INBOARD CORROSION (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)REMOVED, REPLACED AND INSTALLED NEW GALLEY 1 FWD INBOARD MOUNTING BOLT FITTING P/N SH670-32149 REF CRJ 700 SRM 51-42-21-001-001-A01 AND DWG. NO. SH670-3212SDR SWI2024F00950Floor Support · corrodedMULTIPLE SPOTS OF CORROSION ON T-CAP AT LBL9 AT APPROXIMATELY FS855.00 - FS977.00 AS MARKED (C-CHECK RO 10/7/2024) (FILED OPEN)PERFORMED A BEAM REPAIR FROM FS855.00 TO FS904.00 PER CRJ 700 SRM 53-00-41-201-001-A01 AND REO# 670-53-51-301 REV:-- DATE:2024-08-12 SDR SWI2024F00947Floor Support · corrodedMULTIPLE SPOTS OF CORROSION NOTED ON R/H FLOOR BEAM CAP AT LBR 9 AT APPROX. FS485.40 TO FS565.00 (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)REPAIRED FLOOR BEAM CAP AT RBL 9.0 BETWEEN F/S 476.55 TO F/S 571 IAW CRJ 700 SRM 53-00-41-201-001-A01 AND REO 670-53-31SDR SWI2024F00946Floor Support · corrodedMULTIPLE SPOTS OF CORROSION NOTED ON R/H FLOOR BEAM CAP AT RBL 9 AT APPROX. FS565.40 TO FS677.00 (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)INSTALLED NEW FLOOR BEAM FROM RBL 9 FS 565 TO FS 677. REF CRJ700 SRM 53-00-41-201-001-A01 , REO 670-53-31-913 REV-A DATSDR SWI2024F00945Floor Support · corrodedR/H FLOOR SILL BETWEEN FS677.00 TO FS693.00 HAS CORROSION (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)REMOVED AND REPLACED WITH NEW R/H FLOOR SILL BETWEEN FS677.00 TO FS693.00 REF CRJ 700 SRM 51-42-06-001-001-A01 AND DWG SH670-32170 REV V. COMPLIED WITH SKYWSDR SWI2024F00944Floor Support · corrodedMULTIPLE SPOTS OF CORROSION NOTED ON L/H FLOOR BEAM CAP AT LBL 9 AT APPROX. FS477.40 TO FS565.00 (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)REPAIRED L/H FLOOR BEAM CAP AT LBL 9 AT APPROX. FS477.40 TO FS565.00 IAW CRJ-700 SRM 53-00-41-201-001-A01 REV. 38 DATESDR SWI2024F00943Fitting · corrodedGALLEY 1 STRUCTURE MOUNT BOLT FITTING FWD INBOARD CORROSION (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)REMOVED, REPLACED AND INSTALLED NEW GALLEY 1 FWD INBOARD MOUNTING BOLT FITTING P/N SH670-32149 REF CRJ 700 SRM 51-42-21-001-001-A01 AND DWG. NO. SH670-3212SDR SWI2024F00940Floor Support · corrodedMULTIPLE SPOTS OF CORROSION ON T-CAP AT LBL9 AT APPROXIMATELY FS855.00 - FS977.00 AS MARKED (C-CHECK RO 10/7/2024) (FILED OPEN)PERFORMED A BEAM REPAIR FROM FS855.00 TO FS904.00 PER CRJ 700 SRM 53-00-41-201-001-A01 AND REO# 670-53-51-301 REV:-- DATE:2024-08-12 SDR SWI2024F00930Floor Support · corrodedR/H FLOOR SILL BETWEEN FS677.00 TO FS693.00 HAS CORROSION (MARKED) (C-CHECK RO 10/7/2024) (FILED OPEN)REMOVED AND REPLACED WITH NEW R/H FLOOR SILL BETWEEN FS677.00 TO FS693.00 REF CRJ 700 SRM 51-42-06-001-001-A01 AND DWG SH670-32170 REV V. COMPLIED WITH SKYWSDR SWAA2024071802128Angle · crackedCRACK ON ANGLE LOCATED CEILING AREA BTW BS 727B TO BS 727E LBL 50 AT AFT CARGO COMPARTMENT 2024-393186<[01] ON STEP 6: TOOL USED EDDY CURRENT EQUIPMENT PN: NORTEC500D; SN: N500X11290U021704; DUE DATE: 14 APR 25;[02] TOOL USED: PRECISION RADIUS GAUGE PN: S167C;SDR SWAA2024071802039Tie Clip · crackedCRACK TIE CLIP LOCATED STA 277 AND STR 10R AT PASSENGER CABIN 2024-393159<[01] TOOL USED: ELECTRONIC CALIPER P/N: 500-752-20; S/N: B21038234; DUE DATE: 31-OCT-24.;[02] REPELED NEW TIE CLIP LOCATED STA 277 AND STR 10R AT PASSENGER CABIN IAW B737 SRM 51-40-02 ANSDR SWAA2024071802033Intercostal · crackedCRACK WEB - INTERCOSTAL LOCATED BTW STA 294.5 TO STA 303.9 STR 16L AT PASSENGER CABIN 2024-393156<[01] TOOL USED: DIGITAL CALIPER P/N 700-113-10 S/N 0033168 DUE DATE 22-DEC-24;[02] REPLACED WEB - INTERCOSTAL LOCATED BTW STA 294.5 TO STA 303.9 STR 16L AT PASSENSDR SWAA2024071802112Web · crackedCRACK ON LOWER SNUBBER WEB AT FWD ENTRY DOOR 2024-376728<[01] REPLACED (ACESS PANEL) LOWER SNUBBER WEB AT FWD ENTRY DOOR IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING 141A6260 REV. C. SEE INDIVIDUAL SIGN OFF BELLOW;[02] TASK COMPLETED<BR><BR>SEE INDIVIDUAL SIGNSDR SWAA2024071802126Web · crackedCRACK ON WEB LOCATED BTW 500 TO BS 500A AT LEVEL STR 26L AT FWD CARGO COMPARTMENT 2024-393180<[01] REPLACED WEB LOCATED BTW 500 TO BS 500A AT LEVEL STR 26L AT FWD CARGO COMPARTMENT I.A.W. B737-700 SRM; 51-40-02-0G-0 ; DWG 143A7505 REV: - SEE INDIVIDUAL SIGN OFSDR SWAA2024071802127Web · crackedCRACK ON WEB LOCATED CEILING AREA BTW BS 847 TO BS 867 AT AFT CARGO COMPARTMENT 2024-393184<[01] REPLACED WEB LOCATED CEILING AREA BTW BS 847 TO BS 867 AT AFT CARGO COMPARTMENT IAW B737-700 51-40-02 AND DWG 149A8100 REV: - SEE INDIVIDUAL SIGN OFF BELOW;[02] RESDR AALA202407167716Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FORWARD GALLEY BETWEEN FR 20 AND FR 24 AND -Y765. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR CALA2024062601906Door Sill · crackedFWD CABIN WET AREA L-1 DOOR LOWER SILL INNER CHORD CRACKED AT STA 303.9 LBL 60 MKD DOT 075. REF AAR N/R 9890647. REMOVED AND REPLACED INNER CHORD AT STA 303,9 LBL WORK ACCOMPLISHED BY V913200. 60 PER REF SRM 51-40-02-0G-0 AND DWG 141A8110. REMOVED EWIS PROTECTSDR AALA202406253707Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL FROM STA 500D TO STA 500E, RBL 21. ACCOMPLISHED SPLICE REPAIR PER SRM 53-00-53-2R-5.SDR AALA202406258462Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL FROM STA 500C TO STA 500D, S25L. ACCOMPLISHED SPLICE REPAIR PER SRM 53-00-53-2R-5.SDR AALA202406256496Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL FROM STA 500A TO STA 500I, S25R. ACCOMPLISHED SPLICE REPAIR PER SRM 53-00-53-2R-5.SDR AALA202406258140Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT TRANSITION PANEL FROM STA 500C TO STA 500D, RBL 25. ACCOMPLISHED SPLICE REPAIR PER SRM 53-00-53-2R-5.SDR AALA202406256693Support · corrodedAIRCARFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT AFT BULKHEAD SUPPORT ASSEMBLY AT STA 500I, LBL 23. REPLACED SUPPORT ASSEMBLY PER AARD 51-00-05-1.SDR DALA2024061806184Floor Support · broken(LOG 0397046) FLOOR SUPPORTS AT STA 540 FROM RBL 24- LBL 24 ARE BROKEN WL 208. REMOVED, REPLACED AND INSTALLED NEW BREAK PANELS @ STA 540 FROM RBL 24 TO LBL 24 WL 208. IAW B737-900 SRM 51-40-02-0G.SDR DALA2024061806181Floor Support · corroded(LOG 0395388) FLOOR SUPPORT UPPER CHORD HAS CORROSION AT STA 947+11 RBL 49 WL 208. REMOVED AND REPLACED FLOOR SUPPORT UPPER CHORD AT STA 947+11 RBL 49 WL 208 PER B737-900 SRM 51-40-02-0G AND DWG 147A5650.SDR DALA2024061806162Floor Support · corrodedSHIP 3275 DISC: CORROSION FLOOR SUPPORT -Y765 LOCATED AT FR 20 AT FWD GALLEY AREA (SSI 5 31189). REPLACED FLOOR SUPPORT -Y765 LOC. FR 12 TO FR 24 AT FWD GALLEY ARE AS PER SRM 51-42-11 AND SRM 51-72-11, AS PER SRM 51- 42-11 AND DWG D53112814, DWG D53918123, SDR CALA2024061701828Shear Web · corrodedCABIN FLOOR STRUCTURE CORROSION AT L/H SHEAR WEB BETWEEN FR69 AND FR 70 . REMOVED AND REPLACED LH SHEER WEB BTW FR69 AND FR70 IAW A319 SRM 51-72-11-911-001.SDR DALA2024061706128Web · corrodedSHIP 3132 CORROSION WEB INTERNAL STRUCTURE LOCATED FR30 TO FR34 AND STR38R IN FW D CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED WEB LOC. ON INTERNAL STRUCTURE BTW FR30 TO FR34 AND STR38R IN FWD CARGO COMPARTMENT AS PER A319 SRM 51-42-11 AND A319 SRM 51-72-11SDR DALA2024061606112Floor Support · corrodedCORROSION ON FLOOR SUPPORT STA 148 TO STA 200 X=5 AT PAX CABIN FLOOR STRUCTURE. IN REFERENCE NRC 00604. SUMMARY OF NRC 00789: CORROSION LEVEL 2. FLOOR SUPPORT STA 148 TO STA 200 X=5 AT PAX CABIN FLOOR STRUCTURE WAS FABRICATED AND INSTALLED PER DWG 9936534 REV SDR R61A2024061400258Floor Support · corrodedPAX CABIN FLOOR STRUCTURE DOUBLER AT FRAME 12 - 16 LBL 50 FOUND TO HAVE CORROSION. REPLACED DOUBLER IAW SRM 51-43-04 AND 51-41-02SDR R61A2024061400257Web · corrodedPAX CABIN FLOOR SUPPORT STRUCTURE WEB AT FRAME 19-20 LBL 10-24 FOUND TO HAVE CORROSION ON UPPER SURFACE. REPLACED FLOOR SUPPORT STRUCTURE IAW SRM 51-41-02 AND 51-43-04.SDR AALA202408135321Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT GALLEY AREA SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR AALA202408096089Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT GALLEY AREA FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR SCNA20240806291Channel · corrodedLOWER FUSELAGE AFT CARGO COMPARTMENT FLOOR STRUCTURE LBL 25.2. ZEE CHANNEL SIDEPLATE WITH CORROSION AT SEVERAL PLACES. REPLACED FLOOR ZEE CHANNEL LH SIDE PLATE PN BAC 1496-377 FROM STA727+4" TO STA 847" LBL 21 WITH TWO REPAIR SPLICES INSTALLED FORM STA 727+6.SDR AALA202407190840Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LOWER SILL AT STR 23R LOCATED BETWEEN FR 66 AND FR 68 IN AFT GALLEY AREA. REPLACED LOWER SILL PER SRM 51-42-11-801.SDR SWAA2024071801784Support Angle · crackedL/H FWD WING TO BODY FAIRING SUPPORT ANGLE ATTACHED TO FIXED L/E I/B END CRACKED MKD DOT<[01] REMOVED; LOCATED; DRILLED AND INSTALLED L/H FWD WING TO BODY FAIRING SUPPORT ANGLE ATTACHED TO FIXED L/E IAW SRM 51-40-02-0G-0 AND DWGS 116A3118 /116A3110 AND SRM 51-SDR SWAA2024071801785Support Angle · crackedR/H FWD WING TO BODY FAIRING SUPPORT ANGLE ATTACHED TO FIXED L/E I/B END CRACKED MKD DOT<[01] REMOVED AND REPLACED ANGLE AT R/WING FWD WING TO BODY FAIRING SUPPORT ATTACHED TO FIXED L/E AT I/B END PER B737-700 SRM 51-40-02-0G AND BOEING DRAWING 116A3118.;[02] SDR SWAA2024071101781Angle · crackedCRACK ANGLE LOCATED BS663 BETWEEN RBL 10 UPPER POSITION AT CENTER WING BOX 2024-384326<[01] REPLACED ANGLE LOCATED BS663 BETWEEN RBL 5 TO RBL 65 UPPER POSITION AT CENTER WING BOX FOR REPLACED SEE TTG8Q00TX1RG;[02] CORRECTED STEP 1.<BR>REPLACED ANGLE LOCATED BSSDR SWAA2024062702640Threshold · crackedAFT CARGO AFT CORNER THRESHOLD PLATE IS CRACKED<[01] LOCATED; DRILLED AND COUNTERSUNK AFT CARGO AFT NEW CORNER THRESHOLD PLATED PER SRM 51-40-05 AND 51-40-08;[02] INSPECTED WORK ABOVE;[03] INSTALLED NEW AFT CORNER THRESHOLD. AMM 53-11-02.;[04] VERIFIED CA-3. MSDR SWAA2024062702641Threshold · crackedAFT CARGO FWD. CORNER THRESHOLD PLATE IS CRACKED<[01] LOCATED; DRILLED AND COUNTERSINK AFT CARGO FWD NEW CORNER THRESHOLD PLATED PER SRM 51-40-05 AND 51-40-05;[02] LOCATED; DRILLED AND COUNTERSUNK AFT CARGO FWD NEW CORNER THRESHOLD PLATED PER SRM 51-40-05 AND SDR CALA2024061901869Shear Web · corrodedCABIN FLOOR STRUCTURE CORROSION AT R/H SHEAR WEB BETWEEN FR 69 A ND 70 AFT OF R-2 DOOR. REMOVED AND REPLACED RH SHEAR WEB BETWEEN FR69-70 AFT OF R-2 DOO R IAW A319 SRM 51-42-11/001.
Back to JASC 5320