JASC 5320
Service difficulty reports · 216,074
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2026072881087Adapter · corrodedMDC RH SIDE, CLS AT Y0/FR30 WITH CORROSION 31-040 INSTALLED NEW CLS ADAPTER AT MAIN CABIN YO FR30 IAW SRM 51-40-21-001.SDR IPXA2026072880925Adapter · damagedMDC RT SIDE, CLS AT Y0/FR32 WITH CORROSION 31-39. INSTALLED NEW CLS ADAPTER TRAVELER # T26/1872231 ON MDC FLOOR STR AT FR32, Y0 IAW A300-600 SRM 51-40-21.SDR CALA2026072017853Structure · damagedREPAIR ON LOWER WING STRUCTURE FOR 192DR HIGH-PRESSURE DUCT DOOR IS DAMAGED. AFTER DISASSYMBLY FOUND TRIMOUT HAS NOT BEEN DONE CORRECTLY & NEEDS TWO MORE 3/16 HILOCKS AT 3D MIN ON EITHER SIDE OF CUTOUT IAW SRM 57-10-13-2R-3. EVALUATED AND MEASURED DAMAGE BOTHSDR IPXA2026071680937Floor Support · corrodedMDC FLOOR STR AT FR29, Y100 BELOW PANEL 231XG, CLS ADAPTER HAS CORROSION , DOT 78-23. REMOVED 1 EA CORRODED CLS IAW SRM 51-40-21-001. INSTALLED CLS ADAPTER ON MAIN DECK FLOOR STR AT FR29,Y100 BELOW PANEL 321XG IAW SRM 51-40-21-001SDR IPXA2026071680987Adapter · corrodedMDC FLOOR STR AT FR28 Y-100, CLS HAS CORROSION , INSTALLED NEW CLS ADAPTER TRAVELER T26/1871957 ON MDC FLOOR STR AT FR28 Y-100 IAW A300-600 SRM 51-40-21-001.SDR IPXA2026072549120Drain · corrodedAFT CARGO COMP. FLOOR LEVEL BETWEEN FR.59. & FR.60. UNDER FLOOR PANEL 152MG DRAINAGE PLATE CORRODED (4SPOTS)/ REMOVED CORROSION IAW A300-600 SRM 51-74-10, REMOVED NUTPLATES IN REWORKED AREA AS REQUIRED IAW A300-600 SRM 51-40-21, CHECKED LIMITS AND FOUND TO BE SDR IPXA2026091662282Brace · corrodedCEILING PANEL ATTACHMENT FITTING AT FR 54, BTW Y953 AND Y1456 IS CORRODED. REMOVED CORROSION ON FITTING AT FR 54, BTW Y953 AND Y1456 UNDER FUTHER EVALUATION FOUND OUT OF LIMITS FOR EXCESSIVE CORROSION AND EXCEEDS 10% OF THE PERMITTED DAMAGE I.A.W SRM 51-73-1SDR IPXA2026091648490Drain · corrodedAFT CARGO COMP. FLOOR LEVEL BETWEEN FR.59 & FR.60 DRAINAGE PLATE CORRODED (6SPOTS) UNDER RH FLOOR PANEL 152NG/ REMOVED CORROSION IAW SRM 51-74-10, REMOVED NUTPLATES IN REWORKED AREA AS REQUIRED IAW SRM 51-40-21, CHECKED LIMITS AND FOUND TO BE NEGLIGIBLE DAMAGSDR IPXA2026090362282Attach Fitting · corrodedCEILING PANEL ATTACHMENT FITTING AT FR 54, BTW Y953 AND Y1456 IS CORRODED.SDR IPXA2026082749871Drain Pan · corrodedAFT CARGO COMP. FLOOR LEVEL RH BETWEEN FR.59. & FR.60 UNDER FLOOR PANEL 151MG DRAINAGE PLATE COVER STRAP CORRODED (2SPOTS). PART ATTACHED TO DRAIN PAN ASSEMBLY IAW A300-600 SRM 51-40-21 AND 51-24-00.SDR IPXA2026082749194Drain Pan · corrodedAFT CARGO COMP. FLOOR LEVEL BETWEEN FR.59. & FR.60. UNDER FLOOR PANEL 152MG DRAINAGE PLATE COVER STRAP CORRODED (2SPOTS). PART ATTACHED TO DRAIN PAN ASSEMBLY IAW SRM 51-40-21 AND 51-24-00.SDR IPXA2026082748728Drain Pan · corrodedAFT CARGO BAY FLOOR LEVEL BETWEEN FR.59 & FR.60 DRAINAGE PLATE COVER STRAP CORRODED UNDER RT FLOOR PANEL 152NG. PART ATTACHED TO DRAIN PAN ASEMBLY IAW SRM 51-40-21, AND 51-24-00.SDR IPXA2026082148918Floor Support · corrodedAFT CARGO BAY, FLOOR LEVEL AFT FLOOR PANEL 152NG STRUCUTURE CORRODED. INSTALLATION OF SPLICE AT AFT CARGO COMP IAW SRM 51-40-21.SDR SWAA2026081950712Floor Support · corrodedSTA 948 INTERCOSTAL THAT ATTACHES AFT OF FLOORBEAM OF 947 AT LBL 51 HAS PITTING AND CORROSION. LOCATED AND DRILLED NEW INTERCOSTAL PER SRM 51-40-05 AND DRAWING 147A5650. INSTALL WILL BE COMPLETED ON TASK CARD TTG8Q01D6ER9 STEP 7. CORROSION OUT OF LIMITS PESDR HNAA2026081700726Gusset · crackedSERVICE DOOR AFT GUSSET CORRODED BTW FR 22-23. R & R THE GUSSET IAW SRM 51-40-02.SDR HNAA2026081400722Floor Support · corrodedRT OMEGA BEAM CORRODED AT BTW FR60-61. REPAIRED IAW SRM 53-24-10SDR HNAA2026081400723Floor Support · corrodedCTR OMEGA BEAM CORRODED BTW FR60-61. REPAIRED IAW SRM 53-24-10SDR HNAA2026081400720Floor Support · corrodedLEFT OMEGA BEAM IB FLANGE CRACKED AT FR21. REPAIRED IAW ETD2026-145-012350 AND EO 1-53-26-0343SDR HNAA2026081300665Floor Support · crackedCTR OMEGA BEAM IB ANGLE CRACKED AT BTWFR20-21. RAR ANGLE IAW SRM 51-40-02SDR IPXA2026073161872Adapter · corrodedMDC AT FR57.1, Y100 BY FLOOR PANEL 251LG, CLS HAS CORROSION, DOT 78-18. REMOVED CLS ADAPTER AT MDC AT FR58, Y100 BY FLOOR PANEL 251LG I.A.W. A300-600 SRM 51-40-20. INSTALLED NEW CLS ADAPTER P/N: A53275402202 IAW TRAVELER #: T26/1871958 ON MDC AT FR57.1, Y100 BSDR DALA2026071604189Floor Support · corrodedPER MTX REQUESTED OI, FOUND CORROSION ON FLOOR EDGE SUPPORT MEMBER AT FR 74, RBL 53. REPLACED EDGE SUPPORT MEMBER PER ASRP 51-42-06. (LP# 1699452; AIRCRAFT WAS GROUNDED)SDR DALA2026071504172Transition Panel · corrodedAFT CARGO COMP LH TRANSITION PANEL CORRODED FROM STA 727I+4 TO 847. REMOVED AND REPLACED AFT CARGO COMP. L/H TRANSITION PANEL FROM STA 727I=4 TO STA 847 IAW B737-900 SRM 53-00-53 AND 51-20-01. (1699092) AIRCRAFT WAS GROUNDEDSDR DALA2026071504152Web · corrodedLEVEL 2 CORROSION, WEB FRAME 20 AT LEVEL STR 23L AT FWD GALLEY AREA. REPLACED THE WEB BTW FR 20 - 24, STR 23L AT FWD GALLEY AREA IAW SRM 51-42-11, SRM 51-72-11, DWG: D53114392 ISSUE: B00, DWG D53114332 ISSUE: B00, DWG D53111225 ISSUE: B00, AND DWG D5311SDR DALA2026071404141Intercostal · corrodedCORROSION LEVEL 2 IN INTERCOSTAL BS 1500 LBL 2 AT AFT CARGO BAY. INTERCOSTAL STA 1500 LBL 2 AT AFT CARGO BAY WAS REPLACED IAW SRM 51-40-02-0G PAR. 4 B AND 7 D. (LP 1698647 - AIRCRAFT WAS GROUNDED).SDR JR2R20260714724Floor Support · corrodedFWD WET AREA FLOOR SUPPORT BRACKET AT FR 16 RBL 25 CORRODED. REPLACEDSDR JR2R20250714662Angle · corrodedFRAME 15, RT FLOOR ATTACH ANGLE IS CORRODED OUT OF LIMITS. REPLACED.SDR IPXA2026091144552Profile · crackedMDC BULKHEAD AREA Z PROFILE AT FR80 WITH CRACK. INSTALLED Z PROFILE FROM MDC BULKHEAD AREA FR80 IAW SRM 51-40-21SDR AALA202608248301Fork · wornAIRCRAFT IN BASE MAINTENANCE: AFT AVIONIC COMPARTMENT RACK 80VU RIGHT LATERAL FORK END FITTING WORN BETWEEN FR 23 AND FR 24 AT S32R -MAINTENANCE REPLACED RIGHT HAND LATERAL FORK END FITTING PER AARD 53-20-00-1 AND SRM 51-72-11SDR IPXA2026081743772Floor Support · crackedMAIN DECK FLOOR STR AT FR74LH Y2127.6 BELOW FLOOR PANEL 261PF, "Z" PROFILE HAS A CRACK, DOT 78-16 INSTALLED AIW A300-600 SRM 51-40-44. INSPECTED AND VERIFIED INSTALLATION OF "Z" PROFILE I.A.W A300-600 SRM 51-40-44.SDR SWAA2026081976906Floor Support · crackedFLOOR SUPPORT CRACKED STA 540 AT RBL 1 REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-40-02 AND IPC 53-42-11-66 INSPECTED AS REQUIRED CORRECTIVE ACTION #1SDR SWAA2026081931464Floor Support · crackedFLOOR SUPPORT CRACKED BS 540 AT LBL 1, REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-02 AND IPC 53-42-11-66.SDR SWAA2026081746486Strap · corrodedCORRODED TEE STRAP, BS 887, BTWN STRINGERS 27L - 25R, AFT CARGO BAY. REPLACED THE TEE STRAP IAW SRM 51-40-02-0G, SRM 51-10-02, ITEM 9, DWG 146A7500, SHEET 236, REV -, & DWG 149A8104, SHEET 1, REV B.SDR SWAA2026081737204Support Channel · corrodedCORROSION ON SUPPORT ZEE, BTWN BS 500A - 500D + 10 INCHES, RBL 21, WL 156 IN THE FWD CARGO BAY. REPAIRED SUPPORT CHANNEL IAW SRM 53-00-53-2R-5, REPAIR 5, & EA M-22-153-01550 REV A.SDR SWAA2026081768901Web · corrodedCORRODED SHIELD WEB, BS 847 - 867, WL 156, RBL 21. REPLACED SHIELD WEB AND FASTENERS IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, & DWG 146A0081, SHEET 49, REV A.SDR SWAA2026081780982Fitting · crackedCRACKED FITTING, BS 947.5, STR 26L IN THE AFT CARGO BAY. REPLACED THE FITTING IAW SRM 51-10-02, ITEM 9, & SRM 51-40-02.SDR SWAA2026081721686Web · corrodedCORRODED SHIELD WEB BTWN BS 767 - 794.3, WL 156, RBL 22 IN THE AFT CARGO BAY. REPLACED THE SHIELD WEB & FASTENERS IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, & DWG 146A0081, SHT 49, REV A.SDR SWAA2026081786066Web · corrodedCORRODED WEB, BS 747 - 767, RBL 21, WL 156 IN THE AFT CARGO BAY. REPLACED THE WEB IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, DWG 146A7500, SHEET 236, REV -, & DWG 146A7502, SHEET 50, REV -.SDR SWAA2026081796776Support Bracket · crackedCRACKED SUPPORT BRACKET, AFT FACE OF PRESSURE BULKHEAD BS 727, RBL 3, IN THE AFT CARGO BAY. REPLACED THE SUPPORT BRACKET IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 144A2600, SHT 1084 REV-.SDR HNAA2026081700728Web · crackedFWD CENTER WEB BTWN FR 1A - 2 CRACKED IN 2 PLACES. REPAIRED IAW SRM 53-11-10.SDR HNAA2026081700727Gusset · corrodedLEFT GUSSET CORRODED BTW FR 59-60. R & R THE GUSSET IAW SRM 51-40-02.SDR SIMA20260713005Profile · gougedSSI 52-43-002-0001 FWD AVONICS BAY ACCESS DOOR HAS GOUGING ON SURROUND FRAME WITH PREVIOUS BLENDING COMMON TO BOTH AFT DOORSTOP FITTINGS. (MAJOR REPAIR) EVALUATED GOUGES ON DOOR NO ALLOWABLE LIMITS FOUND. LOCATED, DRILLED, DEBURRED, AND TREATED FASTENER HOLES SDR HNAA2026081400681Floor Support · corrodedGALLEY FLOOR PAX DOOR FUSELAGE CUT-OUT LWR CENTER FLOOR SILL FWD SUPPORT HAS CORROSION. REMOVED AND REPLACED GALLEY FLOOR PAX DOOR FUSELAGE CUT-OUT LWR CENTER FLOOR SILL FWD SUPPORT IAW SRM 51-40-02 AND SRM 51-40-09SDR HNAA2026081400680Floor Support · corrodedGALLEY FLOOR PAX DOOR FUSELAGE CUT-OUT LWR CENTER FLOOR SILL AFT SUPPORT HAS CORROSION. REMOVED AND REPLACED GALLEY FLOOR PAX DOOR FUSELAGE CUT-OUT LWR CENTER FLOOR SILL AFT SUPPORT IAW EMB145 SRM 51-40-02SDR HNAA2026081400679Floor Support · corrodedNR 3 LH FLOOR OMEGA BEAM GUSSET CORRODED IN MULTIPLE AREAS. R & R THE LH NR 3 OMEGA BEAM GUSSET IAW SRM 51-40-02.SDR HNAA2026081400678Floor Support · corrodedNR 2 RT FLOOR OMEGA BEAM GUSSET CORRODED IN MULTIPLE AREAS. REMOVED AND REPLACED NR 2 RT FLOOR OMEGA BEAM GUSSET IAW SRM 51-40-02.SDR HNAA2026081400677Floor Support · corrodedNR 1 RT FLOOR OMEGA BEAM GUSSET CORRODED IN MULTIPLE AREAS. REMOVED AND REPLACED RT FLOOR OMEGA BEAM GUSSET NR 1 IAW SRM 51-40-02.SDR HNAA2026081400676Floor Support · corrodedNR 3 LH FLOOR SILL CORRODED IN MULTIPLE AREAS. AFTER BLEND OUT FOUND #3 LH FLOOR SILL TO BE OUT OF ALLOWABLE LIMITS IAW EMB145 SRM 53-22-10. S/N 524 , RAR #3 LH FLOOR SILL IAW EMB 145 SRM 51-40-02SDR HNAA2026081400675Floor Support · corrodedNR 2 LH FLOOR SILL CORRODED IN MULTIPLE AREAS. REMOVED AND REPLACED #2 LH FLOOR SILL IAW EMB 145 SRM 51-40-02.SDR SWAA2026081294700Support Angle · crackedCRACK SUPPORT ANGLE LOCATED BETWEEN BS 344 - 360, RBL 5 EQUIPMENT/ELECTRONIC COMPARTMENT. REPLACED THE SUPPORT ANGLE IAW SRM 51-40-02 & SRM 51-10-02, ITEM 9.SDR IPXA2026071644754Support Angle · crackedMDC RH SIDE, ANGLE SUPPORT UNDER SEAT TRACK -Y1580.5 AT FR 79 WITH CRACK. INSTALLED ANGLE ON MAIN DECK UNDER SEAT TRACK -Y1580.5 AT FR79 IAW A300-600 SRM 51-40-21-001.
Back to JASC 5320