What was found
REPAIR ON LOWER WING STRUCTURE FOR 192DR HIGH-PRESSURE DUCT DOOR IS DAMAGED. AFTER DISASSYMBLY FOUND TRIMOUT HAS NOT BEEN DONE CORRECTLY & NEEDS TWO MORE 3/16 HILOCKS AT 3D MIN ON EITHER SIDE OF CUTOUT IAW SRM 57-10-13-2R-3. EVALUATED AND MEASURED DAMAGE BOTH ON THE CHORD & REPAIR STRAP, SOURCED REPAIR STRAP MATERIAL PER ECRA #5713-01031. FABRICATED STRAP & FILLER IAW STEP 8 & 9 IAW ECRA 5713-01031. COMPLIED WITH STEPS 9 & 11 PENETRANT INSPECTION PER SOPM 20-20-02. NO DEFECTS NOTED ON FARBRICATED PIECE. ALODINED, PRIMED STRAP AND INSTALLED NUTPLATES. DOUBLE FLUSH PLUGGED ORIGINAL NUTPLATE HOLES PER STEP 12. INSTALLED REPAIR STRAP,FILLER & STRIKER PLATE IAW ECRA 5713-01031, SRM 51-40-02, AND. 57-10-13-2R-3.