JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202406076370Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT GALLEY SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR PLATE PER SRM 51-42-11-801.SDR SWAA2024052074456Plate · corrodedCORROSION ON PLATE LOCATED FLOOR STRUCTURE AT BS 847 RBL 21 AND WL 156 AFT CC 2024-253408<[01] REPLACED PLATE LOCATED FLOOR STRUCTURE AT BS 847 RBL 21 AND WL 156 AFT CC I.A.W B737-700 SRM 51-10-02 ITEM 9. DUE TO NOT FOUND ALLOWABLE DAMAGE ON SRM. PLATE MUST BESDR AALA202405200426Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT GALLEY AREA SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR SWAA2024051574711Floor Support · crackedMAIN CABIN INTERCOSTAL UPPER ANGLE BETWEEN STA 400-380 RBL 10' CRACK<[01] REMOVED AND REPLACED INTERCOSTAL UPPER ANGLE AT MAIN CABIN STA 380-400 RBL 10' AS PER SRM 51-40-02-0G-0 & DWG 143A5400.;[02] VERIFIED STEP 1SDR SWAA2024051574712Floor Support · crackedMAIN CABIN INTERCOSTAL UPPER ANGLE BETWEEN STA 400-380 RBL 40' CRACK<[01] REMOVED AND REPLACED INTERCOSTAL UPPER ANGLE AT MAIN CABIN STA 400-380 RBL 40' AS PER SRM 51-40-02-0G-0 & DWG 143A5400.;[02] STEP 1 ENTER IN SIGNED IN ERROR AND CERTIFICATION;[03] REMOVESDR AALA202405074583Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LOWER SILL LOCATED AT FR 68 AND AT STR 23R IN AFT GALLEY AREA. PERFORMED PERMANENT REPAIR (REPAIR ANGLE AND FILLER) PER SRM 53-41-14-300-001.SDR AALA202404251881Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT LEFT PASSENGER / CREW DOOR CUTOUT LOWER SILL EXISTING REPAIR AT FR 68 AND S23L. REPAIRED LOWER SILL PER SRM 53-41-14-300-001 FIGURE 001(SHEET 1 AND SHEET 3) REPAIR PRINCIPLE 5.SDR AALA202404188926Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: AFT CABIN FLOOR SHEAR PLATE CRACKED BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR P,LATE PER ARM 51-42-11.SDR IPXA2024061087686Support Angle · corrodedFAULT - MXP-531535-01-1-151- AFT CARGO FR54 BLKHD RH UPPER ANGLE IS CORRODED DOT 5612-1 INSTALLED NEW AFT CARGO BLKH RIGHT UPPER ANGLE IAW SRM 51-40-21 REVIEWEDSDR SWAA2024052274513Floor Support · crackedFWD CARGO INTERCOSTAL BS 500A TO BS 500B CRACKED. FWD CARGO INTERCOSTAL BS 500A TO BS 500B LBL22 CRACKED. WL 156<[01] UPDATED MEASUREMENTS TABLE;[02] REMOVED AND REPLACED INTERCOSTAL IAW INTERCOSTAL IAW SRM 51-40-02; SRM 53-30-53-2R-1 AND DWG 143A7505 REV A;[0SDR SWAA2024052277828Floor Support · deformedFWD CARGO INTERCOSTAL BS 500 TO BS 500A LBL22 BENDED FWD CARGO INTERCOSTAL BS 500 TO BS 500A LBL22 BENDED WL 156<[01] REMOVED AND REPLACED INTRCOSTAL IAW SRM 51-40-02 AND DWG 143A7505 REV:;[02] VERIFIED ALL STEPS AND CORRECTIVE ACTION ITEMS; CARD COMPLETE.SDR SWAA2024052274252Support Angle · crackedCRACK AT SUPPORT ANGLE STA-685+10'' LBL-25 WL-208<[01] UPON FURTHER INVESTIGATION AND VERIFIED BY NDI; SUPPORT ANGLE AT BS 685+10' LBL 25 WL 208 FOUND TO BE CRACK FREE. NO FURTHER ACTION REQUIRED;[02] VERIFIED STEP 1 IS COMPLIED WITH; CARD COMPLETE.SDR HNAA2024051600409Support · corrodedE032496 GALLEY FWD DIGITAL IS CORRODED AT LH AND CENTER BEAM POSITIONS ON AFT END. REPAIRED GALLEY FWD DIGITAL CORROSION AT LH AND CENTER BEAM POSITIONS ON AFT END IAW PIEDMONT EO1-53-24-0295 AND ETD2024-145-011366SDR HNAA2024051600399Floor Support · corrodedE032414 CORROSION ON LH OMEGA BEAM #2 GUSSET. REMOVED UNSERVICEABLE AND INSTALLED SERVICEABLE L/H OMEGA BEAM #2 GUSSET IAW EMB 145 SRM 51-40-02.SDR HNAA2024051600398Floor Support · corrodedE032410 CORROSION ON CENTER OMEGA BEAM #1 GUSSET. REMOVED UNSERVICEABLE AND INSTALLED SERVICEABLE CENTER OMEGA BEAM #1 GUSSET IAW EMB 145 SRM 51-40-02.SDR SWAA2024051474490Support Angle · brokenBROKEN SUPPORT ANGLE STA 867 AND BTW STR 2R TO STR 3R AT PASSENGER CABIN. REPLACED SUPPORT ANGLE STA 867 AND BTW STR 2R TO STR 3R AT PASSENGER CABIN IAW B737-800 SRM 51-40-02 DWG 146A7901; SHEET 99; REV -.SDR SWAA2024051474368Intercostal · crackedCRACK WEB - INTERCOSTAL BETWEEN BS 927 TO BS 947 AND STRINGER 25R AFT CARGO COMPARTMENT. REPLACED WEB - INTERCOSTAL LOC. BETWEEN BS 927 TO BS 947 AND STRINGER 25R AFT CARGO COMPARTMENT IAW B737-800 SRM 51-40-02 AND DWG 147A7500 SHEET 40 REV -.SDR SWAA2024051474367Support Angle · crackedCRACK ANGLE - SUPPORT BS 867 BETWEEN STRINGER 25L TO STRINGER 26L AFT CARGO COMPARTMENT. REPLACED ANGLE-SUPPORT LOCATED BS867 BETWEEN STRINGER 25L TO STRINGER 26L AFT CARGO COMPARTMENT IAW B737-800 SRM 51-10-02 ITEM 9 AND DWG #149A8102 SHEET 19 REV.A; DWG #1SDR HNAA2024051400377Door Sill · corrodedE032492 SERVICE DOOR CENTER SILL IS CORRODED AT FWD AND CENTER SCREW HOLES. REMOVED CORRODED SERVICE DOOR CENTER SILL AND INSTALLED SERVICEABLE SERVICE DOOR CENTER SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2024051400367Floor Support · corrodedE032479 LH #3 FLOOR SILL CORRODED. RAR L/H #3 FLOOR SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2024051400366Floor Support · corrodedE032464 CENTER OMEGA BEAM GUSSET AROUND NUTPLATE HOLE AT FR-39 HAS CORROSION. REMOVED AND REPLACED CENTER OMEGA BEAM GUSSET IAW EMB 145 SRM 51-40-02SDR HNAA2024051400365Floor Support · corrodedE032461 R/H FLOOR SILL #3 HAS CORROSION AT MULTIPLE AREAS. REMOVED AND REPLACED R/H FLOOR SILL #3 IAW EMB 145 SRM 51-40-02SDR HNAA2024051400364Floor Support · corrodedE032449 L/H OMEGA BEAM GUSSET AT FR-49 HAS CORROSION. RAR #6 L/H OMEGA BEAM GUSSET IAW EMB 145 SRM 51-40-02.SDR HNAA2024051400355Support · corrodedE032424 LAV L/H WATER LINE SUPPORT IS CORRODED UNDERNEATH. RAR THE LAV LH WATER LINE SUPPORT IAW EMB 145 SRM 51-40-02.SDR HNAA2024051400354Support Bracket · corrodedE032383 RAMP SUPPORT FLANGE BRACKET CORRODED AT FR20. REMOVED AND REPLACED RAMP SUPPORT FLANGE BRACKET AT FR20 IAW EMB 145 SRM 51-40-02.SDR HNAA2024051400351Gusset · corrodedE032379 GALLEY CENTER BEAM GUSSET CORRODED. RAR GUSSET IAW EMB145 SRM 51-40-02.SDR HNAA2024051400350Door Sill · corrodedE032378 SERVICE DOOR CUTOUT LWR CENTER SILL CORRODED. BLENDED AS REQUIRED TO REMOVE DAMAGE FROM SERVICE DOOR CUTOUT LOWER CENTER SILL IAW EMB-145 SRM 51-10-03. UT CHECK INDICATES 0.063" REMAINING THICKNESS. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLED BSDR HNAA2024051400349Door Sill · corrodedE032377 SERVICE DOOR CUTOUT LWR AFT SILL CORRODED. RAR SERVICE DOOR CUTOUT LWR AFT SILL IAW EMB 145 SRM 51-40-02SDR HNAA2024051400348Door Sill · corrodedE032376 SERVICE DOOR CUTOUT LWR FWD SILL CORRODED. REMOVED AND INSTALLED SERVICEABLE SERVICE DOOR CUTOUT LWR FWD SILL IAW EMB 145 SRM
51-40-02SDR ASAA2024041349372Web · corrodedFWD CARGO DOOR CUTOUT LWR CLOSE OUT WEB CORRODED. GROUNDED - YES. BLENDED CORR FOUND TO BE OUT OF LIMITS REMOVED & REPLACED LWR CLOSE OUT WEB IAW B737-800 SRM 51-40-02-0G-0 W 1, O ..045, R .038, L 2, D .007.SDR SWAA2024041674254Panel · crackedPANEL 193AR IS DAMAGED AND CRACKED AT OUTBOARD TOP AFT EDGE OF PANEL. R & R THE PANEL 193AR IAW AMM 53-51-21.SDR DALA2024041504427Cusp Web · crackedCRACK ON RH CUSP WEB (BELOW) STA Y=813 AND X=-44 APPROX AT PASSENGER CABIN STRUCTURE. SUMMARY OF NRC 00526: RH CUSP WEB (BELOW) STA Y=813 AND X=-44 APPROX AT PASSENGER CABIN STRUCTURE WAS REPAIRED PER B717-200 SRM 51-70-10-2R REPAIR 1. (LP #0292417)SDR DALA2024041504421Angle · corrodedCORROSION WAS FOUND IN ANGLE OVER CENTER WING UPPER SKIN STA Y=748 X=0. SUMMARY OF NRC 00803: CORROSION LEVEL 2. CORROSION IN ANGLE OVER CENTER WING UPPER SKIN STA Y=748 X=0 WAS REPAIRED PER PRI 616932-14 REV 4 AND ER/A 616932-14 REV ORIGINAL SECTION I: PERMANSDR IXXA2024041301Stiffener · crackedNOSE WHEEL WELL VERTICAL CHORD.SDR 2024FA0000915Support Bracket · crackedFLAP HANDLE FORWARD SUPPORT BRACKET FOUND CRACKED. NOTED AREA OF STRESS/CRACK A LACK OF RADIUS. REPLACED WITH FACTORY NEW BRACKET.SDR 2024FA0000914Support Bracket · crackedFLAP HANDLE FORWARD SUPPORT BRACKET FOUND CRACKED. NOTED AREA OF STRESS/CRACK A LACK OF RADIUS. REPLACED WITH FACTORY NEW BRACKET.SDR SWAA2024052274247Support Angle · corrodedFWD CARGO; CORROSION ON AFT LWR BULKHEAD ANGLE; BS 500D; FROM RBL22 TO LBL22; WL156;<[01] LOCATED AND DRILLED NEW ANGLE P/N 143A9483U35 LOT 1544704-2 IAW SRM 51-40-05;[02] VERIFIED COMPLETION CORRECTIVE ACTION 1;[03] REMOVED AND REPLACED FWD CARGO; AFT LWR BULSDR SWAA2024052274245Sidewall Support · corrodedFWD CARGO; CORROSION ON SIDEWALL SUPPORT; 500A+12; BS500B+14.500B+18; 500C14; RBL22; WL156;<[01] VERIFIED;[02] CARD COMPLETED;[03] EDITED TABLE;[04] VERIFIED;[05] REMOVED CORROSION ON SIDEWALL SUPPORT; 500A+12; BS500B+14.500B+18; 500C14; RBL22; WL156 PER SRM 5SDR SWAA2024052274240Sidewall Support · corrodedFWD CARGO; CORROSION ON SIDEWALL SUPPORT; BS500+9;500+13; 500A+6; 500A+14; LBL22; WL156;<[01] REMOVED AND REPLACED SIDEWALL SUPPORT ON W/C TTG8Q00QAW9;[02] VERIFIED.SDR SWAA2024052274243Shield · corrodedFWD CARGO; CORROSION ON SHIELD SEVERAL SPOTS; BS492; RBL22 WL156;<[01] REMOVED AND REPLACED NEW FCB AFT SHIELD IAW BOEING DWG 143A0080 AND SRM 51-40-02;[02] VERIFIED COMPLETION CORRECTIVE ACTION 1 AND MEASUREMENT TABLE.SDR SWAA2024052274235Sidewall Support · corrodedFWD CARGO; CORROSION ON SIDEWALL SUPPORT; BS400+7; BS 400+19; BS420+5; LBL22; WL156.<[01] REMOVED AND REPLACED FCB LH FLOOR TO SIDEWALL SUPPORT IAW BOEING DWG 143A7500; 143A7501 AND SRM 51-40-02;[02] CUSTOMER CARD COMPLETESDR SWAA2024052274232Shield · corrodedFWD CARGO; CORROSION ON SHIELD; SEVERAL SPOTS; BETWEEN BS420& 440;RBL22;WL156<[01] REMOVED AND REPLACED NEW FCB FWD SHIELD IAW BOEING DWG 143A0080 AND SRM 51-40-02;[02] VERIFIED COMPLETION CORRECTIVE ACTION 1 AND MEASUREMENT TABLE.SDR SWAA2024052173895Scuff Plate · crackedAFT CARGO BAY DOOR AFT CORNER SCUFF PLATE CRACKED<[01] EDITED LOT NUMBER OF FILLER ROD IN STEP 2 TO READ CORRECTLY;[02] CARD IS COMPLETED;[03] CUSTOMER CARD COMPLETE <BR>VERIFIED MEASUREMENT TABLE.SDR SWAA2024052074063Plate · corrodedCORROSION PLATE LOCATED FLOOR STRUCTURE BS 1016 PLUS 15 INCHES LBL 2 WL 208.1 AT AFT GALLEY AREA 2024-259091<[01] REPLACED PLATE AND FASTENERS LOCATED FLOOR STRUCTURE BS 1016 PLUS 15 INCHES LBL 2 WL 208.1 AT AFT GALLEY AREA IAW B737-700 SRM 51-40-02-0G-0; SRM SDR HNAA2024051600403Door Sill · corrodedE031897 CARGO DOOR CUTOUT LOWER SILL CORRODED. REMOVED AND REPLACED CARGO DOOR CUTOUT LOWER SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2024051600397Floor Support · corrodedE032103 CORROSION ON RH OTBD #5 FLOOR SILL. R & R R/H #5 OTBD FLOOR SILL IAW EMB 145 SRM 51-40-02SDR HNAA2024051600396Floor Support · corrodedE032102 CORROSION ON RH OTBD #4 FLOOR SILL. REMOVED AND REPLACED RH OTBD #4 FLOOR SILL IAW EMB145 SRM 51-40-02SDR SWAA2024051474096Angle · crackedCRACK ANGLE LOCATED ON BS727 AND STR25L TO STR25R AND AFT CARGO COMPARTMENT. REPLACED ANGLE LOCATED ON BS727 AND STR25L TO STR25R AND AFT CARGO COMPARTMENT IAW B737-800 SRM 51-10-02 ITEM 9 AND DWG 453A2600 SHEET 117 REV -.SDR HNAA2024051400372Door Sill · corrodedE032049 CARGO DOOR STRUCTURE CUTOUT LWR CENTER SILL CORRODED. RAR THE CARGO DOOR STRUCTURE CUTOUT LWR CENTER SILL IAW EMB 145
SRM 51-40-02SDR HNAA2024050900339Angle · corrodedCARGO COMPARTMENT DOOR FUSELAGE CUTOUT ANGLE AT FRM68 BETWEEN STGR17L AND STGR18L IS CORRODED. REMOVED AND INSTALLED NEW SERVICEABLE SHEAR CLIP ANGLE PN/ 145-25175-001 IAW EMB145LR SRM 51-40-02
Back to JASC 5320