What was found
CORROSION ON PLATE LOCATED FLOOR STRUCTURE AT BS 847 RBL 21 AND WL 156 AFT CC 2024-253408<[01] REPLACED PLATE LOCATED FLOOR STRUCTURE AT BS 847 RBL 21 AND WL 156 AFT CC I.A.W B737-700 SRM 51-10-02 ITEM 9. DUE TO NOT FOUND ALLOWABLE DAMAGE ON SRM. PLATE MUST BE REPLACED TOOK MEASURES OF CORROSION L= 1.299? W= 1.135? D= 0.047? NOMINAL THICKNESS IS 0.125?. TOOL USED DIGITAL CALIPER: P/N: 500-196-30 S/N: A21033522 DUE DATE: 22-DEC-24;[02] CERTIFIED WORK PERFORMED