JASC 5320
Service difficulty reports · 216,095
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026072437174Angle · crackedCRACK ANGLE LOCATED AFT FACE BS 500G AT LEVEL STR 26L FWD CARGO COMPARTMENT. REPLACED ANGLE LOCATED AFT FACE BS 500G AT LEVEL STR 26L FWD CARGO COMPARTMENT IAW SRM 51-40-02 AND DWG 143A7505 SHEET 138 REV-.SDR SWAA2026072493553Web · crackedCRACKED WEB, BTWN BS 500A - 500B, STR 26R, IN THE FWD CARGO BAY. REPLACED THE WEB IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 143A7505, SHEET 137, REV-.SDR SWAA2026072474065Angle · crackedCRACKED ANGLE, BS 500H, STR 26L FWD CARGO BAY, REPLACED THE ANGLE IAW SRM 51-40-02 AND DWG 143A7505, SHEET 139, REV-.SDR SWAA2026072423185Angle · crackedCRACKED ANGLE, FWD FACE BS 500H, STR 26L IN FWD CARGO BAY. REPLACED THE ANGLE, LOCATED FWD FACE IAW SRM 51-40-02, AND DWG 143A7505, SHEET 137, REV-.SDR SWAA2026072422953Angle · crackedCRACKED ANGLE, AFT FACE BS 500H, STR 26R IN FWD CARGO BAY. REPLACED THE ANGLE IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 143A7505, SHEET 137, AND 138, REV-.SDR SWAA2026072482237Gusset · crackedCRACKED GUSSET ANGLE, BS 500I, STR 19R IN THE FWD CARGO BAY. REPLACED THE GUSSET ANGLE IAW SRM 51-40-02-0G-0, SRM 51-10-02, ITEM 9, AND DWG 143A7902, SHEET 256, AND SHEET 257, REV B. .SDR SWAA2026072434343Angle · crackedCRACKED ANGLE, BS 500G, STR 25R. REPLACED ANGLE CLIP AND FASTENERS IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 143A7505, SHEET 137, & 138, REV-.SDR HNAA2026072400618Floor Support · corrodedLEFT OMEGA BEAM GUSSET FROM FR 36 TO FR 41 HAS CORROSION. REMOVED AND REPLACED 1EA LT OMEGA BEAM GUSSET LOCATED BETWEEN FR 36 - FR 41 PER EMB 145 SRM 51-40-02-PR.SDR HNAA2026072400617Floor Support · corrodedLEFT OTBD FLOOR SILL FROM FR 36 TO FR 41 HAS CORROSION. COMPLIED WITH PERMANENT REINFORCING REPAIR OF THE LT OTBD FLOOR SILL FROM FR36 - FR41 PER EMB 145 ETD2026-145-011099 REV.: / AND PIEDMONT EO1-53-26-0304.SDR HNAA2026072400616Floor Support · corrodedRIGHT OTBD FLOOR SILL FROM FR 36 TO FR 41 HAS CORROSION. REMOVED AND REPLACED WITH NEW RT OTBD FLOOR SILL FROM FR 36 TO FR 41 IAW EMB 145 SRM 51-40-02-PR.SDR HNAA2026072400615Floor Support · corrodedLEFT OTBD FLOOR SILL FROM FR 43 TO FR 46 HAS CORROSION. REMOVED AND REPLACED LT OTBD FLOOR SILL FROM FR 43 TO FR 46 IAW SRM 51-40-02-PR.SDR HNAA2026072400614Floor Support · not reportedLEFT OTBD FLOOR SILL FROM FR 47 TO FR 51 HAS CORROSION. REMOVED AND REPLACED LT OTBD FLOOR SILL FROM FR 47 TO FR 51 IAW SRM 51-40-02-PR.SDR HNAA2026072400613Floor Support · corrodedLEFT OTBD FLOOR SILL FROM FR 53 TO FR 57 HAS CORROSION. REMOVED AND REPLACED WITH NEW LT OTBD FLOOR SILL FROM FR 53 TO FR 57 IAW SRM 51-40-02-PR.SDR HNAA2026072400612Floor Support · corrodedRIGHT OTBD FLOOR SILL FROM FR 53 TO FR 57 HAS CORROSION. REMOVED AND REPLACED WITH NEW RT OTBD FLOOR SILL FROM FR 53 TO FR 57 IAW EMB 145 SRM 51-40-02-PR.SDR SWAA2026072176920Shield · corrodedIN THE AFT CARGO BAY RIGHT SIDE, THE SHIELD ASSEMBLY JUST FWD OF THE ENTRY THRESHOLD IS CORRODED. BLENDED AREAS OF CORROSION AT AFT CARGO BAY RIGHT SIDE; THE SHIELD ASSEMBLY JUST FWD OF THE ENTRY THRESHOLD; BLENDS FOUND TO BE OUT OF LIMITS ALL IAW SRM 53-0SDR SWAA2026072167251Angle · corrodedAFT CARGO BAY RT TRANSITION ANGLE, RBL 21, BS 727J+14 WAS CORRODED AT NUTPLATE HOLE. BLENDED AREAS OF CORROSION IN THE AFT CARGO BAY. RT TRANSITION ANGLE, RBL 21, BS 727J+14; BLENDS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. CUT AND REMOVED DAMAGED ASDR U2R2026F00000Frame · crackedDURING OPEN HOLE INSPECTION, DETECTED DEFECT SIGNAL AT FRAME WEB BS 1265. PERFORMED REPAIR IAW NAL FCD 744-53-0014 AND DWG 624U0060.SDR IPXA2026070240523Support Bracket · crackedCRACKED ANGLE, RT BLG W/W HYD TUBE SUPPORT BRACKET AT BS 1480 UNDER BLG HYD TRUCK POSITIONER SHUTOFF FUSE. REVIEWED TASK IAW GMM-MTX 09.05.01.09. INSTALLED NEW ANGLE IAW SRM 51-40-02-0G REV.107, AND DWG 272U4448, SH 6, REV B.SDR SWAA2026070213650Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED BTW BS 500A TO BS 500B AND STR 26R FWD CARGO COMPARTMENT. REPLACED INTERCOSTAL AND NEW FASTENERS LOCATED BTW BS 500A - 500B, STR 26R FWD CARGO BAY IAW SRM 51-10-02 STEP 9 & SRM 51-40-02 AND DWG 143A7505; SHEET 137; REV -.SDR MASA20260626166Structure · corrodedDURING HEAVY CHECK INSPECTIONS OF INTERNAL CFIII FLOOR STRUCTURE, CORROSION FOUND ON UPPER SHEET AT RBL 11, BETWEEN FR 85 RT TO FR 86 RT HAS BEEN REMOVED AND REPLACED IAW SRM 51-43-01. REV 46,SDR MASA20260626165Floor Support · corrodedDURING HEAVY CHECK INSPECTIONS OF INTERNAL CFIII FLOOR STRUCTURE, CORROSION FOUND ON BEAM AT RBL 11, BETWEEN FR 86 RT TO FR 89 RT HAS BEEN REMOVED AND REPLACED IAW SRM 51-43-01 AND SRM 51-42-01. REV 46, NRC 4502654-1000-0041.SDR LR7A2026061903860Support Angle · crackedDURING SCHEDULED C-3 CHECK UNDER JOB CARD HC3211, FOUND MLG WHEEL WELL UPPER WL 200 SUPPORT CLIP CRACKED AT FS 517, LBL 85. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SRM 51-60 & 51-70.SDR LR7A2026061903838Plate · chafedDURING SCHEDULED C-3 CHECK UNDER JOB CARD HC5211, FOUND CARGO FLOOR RAMP END PLATE CHAFED AT BS 817.0E, LBL 48 TO RBL 36, WL 145. REPAIR BY REPLACEMENT ACCOMPLISHED IAW SRM 51-60 & 51-70.SDR DALA2026061903680Cusp Web · crackedCRACK ON CUSP WEB BTW X=-44 AND STA 674, STA 717 ALSO IN X=-56 AND STA 1014 AT CPAX. CUSP WEB BTW X=-44 AND STA 674, CUSP WEB BTW X=-56 AND STA 1014 WERE REPAIRED IAW SRM 53-00-55-2R-4 PAR. 5 FIG. 215, NO CRACKS WERE FOUND AT STA 717 PER NDTSPM PART 6, 06-10SDR DALA2026061903668Panel · corrodedCORROSION OUT OF LIMITS, CORROSION ON LH SIDE PANEL UPPER/LOWER SURFACE FROM BS 1530 TO BS 1550 IAW SRM 53-00-53-1A PROCEDURE 1, ALLOWABLE DAMAGE 1; NOTE C . DETAIL IX. FIG. 101. CORROSION LEVEL 2, LT SIDE PANEL FROM BS 1530 TO BS 1550 WAS REPAIRED PER SRM 5SDR REXA2026082601747Support Angle · crackedCRACK AT FWD SUPPORT ANGLES (2EA) OF UPPER ACUMULATOR AT NOSE HYDRAULICS COMPARTMENT INTERNAL STRUCTURE (INSIDE ACCESS PANEL 121AL). FWD SUPPORT ANGLES (2EA) OF UPPER ACUMULATOR AT NOSE HYDRAULICS COMPARTMENT INTERNAL STRUCTURE (INSIDE ACCESS PANEL 121AL) WERESDR REXA2026082601746Support Angle · crackedCRACK AT FWD SUPPORT ANGLES (2EA) OF UPPER ACUMULATOR AT NOSE HYDRAULICS COMPARTMENT INTERNAL STRUCTURE (INSIDE ACCESS PANEL 121AL). FWD SUPPORT ANGLES (2EA) OF UPPER ACUMULATOR AT NOSE HYDRAULICS COMPARTMENT INTERNAL STRUCTURE (INSIDE ACCESS PANEL 121AL) WERESDR REXA2026082601745Floor Support · crackedCRACK ON FLOOR BEAM RBL 12.0 BTW FS 221.73 TO FS 229.00 AT FWD FUSELAGE INTERNAL STRUCTURE (FLIGHT COMPARTMENT FLOOR STRUCTURE BELOW WL79.50). FLOOR BEAM RBL 12.0 BTW FS 221.73 TO FS 229.00 AT FWD FUSELAGE INTERNAL STRUCTURE (FLIGHT COMPARTMENT FLOOR STRUCTURSDR REXA2026082601727Bracket · corrodedCORROSION ON BLOCK CLAMP SUPPORT BTW FS=295 TO 310, STGR=25R AT E/E COMPARTMENT. CORROSION ON BLOCK CLAMP SUPPORT BTW FS=295 TO 310, STGR=25R AT E/E COMPARTMENT WAS EVALUATED OUT OF LIMITS PER CRJ900 SRM 51-10-06-001-001-A01 AND WAS REPLACED PER CRJ900 SRM 51-SDR REXA2026082601693Floor Support · corrodedCORROSION ON LONGITUDINAL BEAMS (3E/A) FROM FS1000 TO FS1069 ON LBL27, LBL09 AND RBL09 AT AFT BAGGAGE COMPARTMENT CORROSION ON LONGITUDINAL BEAMS (3E/A) FROM FS1000 TO FS1069 ON LBL27, LBL09 AND RBL09 AT AFT BAGGAGE COMPARTMENT WERE EVALUATED OUT OF LIMITS PERSDR REXA2026082601692Floor Support · corrodedCORROSION ON LONGITUDINAL BEAMS (3E/A) FROM FS1000 TO FS1069 ON LBL27, LBL09 AND RBL09 AT AFT BAGGAGE COMPARTMENT CORROSION ON LONGITUDINAL BEAMS (3E/A) FROM FS1000 TO FS1069 ON LBL27, LBL09 AND RBL09 AT AFT BAGGAGE COMPARTMENT WERE EVALUATED OUT OF LIMITS PERSDR REXA2026082601691Floor Support · corrodedCORROSION ON LONGITUDINAL BEAMS (3E/A) FROM FS1000 TO FS1069 ON LBL27, LBL09 AND RBL09 AT AFT BAGGAGE COMPARTMENT CORROSION ON LONGITUDINAL BEAMS (3E/A) FROM FS1000 TO FS1069 ON LBL27, LBL09 AND RBL09 AT AFT BAGGAGE COMPARTMENT WERE EVALUATED OUT OF LIMITS PERSDR REXA2026082601683Fitting · corrodedCORROSION FLOOR FITTING IN AFT ACCESS 205 OUT SIDE (1EA) ON GALLEY 2. SUMMARY OF NRC 00244: FLOOR FITTING IN AFT ACCESS 205 OUT SIDE (1EA) ON GALLEY 2 WAS REPLACED PER SAFRAN CMM 25-32-84 REV 9 DATE JUN 06/24SDR IPXA2026081327919Inlet · corroded*** SUPPLEMENTAL SDR *** HORZ STAB COMPT. APU INLET SURROUND STRUCTURE ANGLE IS CORRODED BETWN STA. 1787.45 TO 1825 STGR S-6R (059-07) ATA: 53-80 SKILL: STR APU INLET SURROUNDIN STRUCTURE FROM STA 1787.45-1825 WILL BE REPAIR ON LINE # 711 T3F18E0090LLM. NO FUTSDR REXA2026073001334Web · corrodedCORROSION ON WEB FLOOR PROTECTOR (4EAS) AT SERVICE DOOR SURROUND STRUCTURE CORROSION ON WEB FLOOR PROTECTOR (4EAS) AT SERVICE DOOR SURROUND STRUCTURE WAS REMOVED AND EVALUATED OUT OF LIMITS PER CRJ900 SRM 51-21-06-001-001-A01 AND CRJ-900 SRM 53-00-00-101-001-SDR REXA2026073001333Bracket · corrodedCORROSION ON WEB FLOOR PROTECTOR (4EAS) AT SERVICE DOOR SURROUND STRUCTURE CORROSION ON WEB FLOOR PROTECTOR (4EAS) AT SERVICE DOOR SURROUND STRUCTURE WAS REMOVED AND EVALUATED OUT OF LIMITS PER CRJ900 SRM 51-21-06-001-001-A01 AND CRJ-900 SRM 53-00-00-101-001-SDR REXA2026073001332Protector · corrodedCORROSION ON WEB FLOOR PROTECTOR (4EAS) AT SERVICE DOOR SURROUND STRUCTURE CORROSION ON WEB FLOOR PROTECTOR (4EAS) AT SERVICE DOOR SURROUND STRUCTURE WAS REMOVED AND EVALUATED OUT OF LIMITS PER CRJ900 SRM 51-21-06-001-001-A01 AND CRJ-900 SRM 53-00-00-101-001-SDR REXA2026073001331Bracket · corrodedCORROSION ON WEB FLOOR PROTECTOR (4EAS) AT SERVICE DOOR SURROUND STRUCTURE CORROSION ON WEB FLOOR PROTECTOR (4EAS) AT SERVICE DOOR SURROUND STRUCTURE WAS REMOVED AND EVALUATED OUT OF LIMITS PER CRJ900 SRM 51-21-06-001-001-A01 AND CRJ-900 SRM 53-00-00-101-001-SDR SWAA2026072435525Support Angle · crackedCRACKED SUPPORT ANGLE LOCATED FWD FACE BS 695 BL 0 WL 208.1 RT SIDE AT PASSENGER CABIN. REPLACED THE SUPPORT ANGLE IAW SRM 51-40-02 AND DWG 273A9111 SHEET 10 REV -.SDR SWAA2026072458657Web · crackedCRACKED WEB, BTW BS 927 - 947.5, STR 24R - 25R. REPLACED THE WEB IAW SRM 51-40-02, SRM 51-10-02, ITEM 9, AND DWG 147A7500, SHEET 37, REV-.SDR SWAA2026072474376Web · crackedCRACKED WEB, BTWN BS 312 - 328, LBL 47.5, WL 208.1. REPLACED THE WEB IAW SRM 51-40-02, AND DWG 141A5400, SHEET 26, REV-.SDR SWAA2026072493596Floor Support · corrodedCORRODED FLOOR SUPPORT BTWN BS 312 - 328, LBL 12, WL 208.1. REPLACED THE INTERCOSTAL AND FASTENERS IAW SRM 51-40-02, AND DWG 141A5400, SHEET 27, REV -.SDR HNAA2026072400626Floor Support · crackedONE LT OMEGA BEAM GUSSET AT FR 28 HAS A CRACK. REMOVED AND REPLACED LH OMEGA BEAM GUSSET AT FR 28 PER EMB 145 SRM 51-40-08-PR.SDR HNAA2026072400623Floor Support · crackedONE LT OMEGA BEAM AT FR 23 HAS A CRACKED. COMPLIED WITH PERMANENT REINFORCING REPAIR OF THE LT OMEGA BEAM AT FRAME 23 SPLICE IAW ETD2026-145-010691 REV. AND PIEDMONT EO1-53-26-0291.SDR HNAA2026072400610Floor Support · corrodedRIGHT OTBD FLOOR SILL FROM FR 25 TO FR 28 HAS CORROSION. REMOVED AND REPLACED RT OTBD FLOOR SILL FROM FR 23 - FR 29 PER EMB 145 SRM 51-40-02-PRSDR HNAA2026072400609Floor Support · corrodedLEFT OTBD FLOOR SILL FROM FR 24 TO FR 29 HAS CORROSION. REMOVED AND REPLACED THE LT OTBD FLOOR SILL FROM FR24 - FR29 PER EMB 145 SRM 51-40-02-PR.SDR HNAA2026072400608Floor Support · corrodedLEFT OTB FLOOR SILL FROM FR 20 TO FR 22 HAS CORROSION. REMOVED AND REPLACED WITH NEW LT OTBD FLOOR SILL FROM FR 20 TO FR 22 IAW EMB 145 SRM 51-40-02 STEP 2 B, C AND 4BSDR HNAA2026072400603Floor Support · corroded00148 1EA RH OB FLOOR SILL AT FR 20 HAS CORROSION. REMOVED AND REPLACED WITH NEW RH OB FLOOR SILL AT FR 20 IAW EMB 145 SRM 51-40-02-PR.SDR IPXA2026071737767Bracket · brokenIAW TASK CARD T3F18E004V6MO LINE 267 STEP 10, LEFT STRUT STA 149.5 BRACKET WAS INSPECTED AND FOUND BROKEN, FLL-050, INSTALLED FRAME ANGLE AT #1 PYLON UPPER SIDE IAW B757-200PF SRM 51-40-02-0G-0SDR SWAA2026071723575Intercostal · corrodedCORROSION ON WEB INTERCOSTAL UPPER SILL LOCATED BS 827 PLUS 2.5 INCH AT LEVEL S-18R AND WL 200 AFT CARGO BAY. REPLACED WEB INTERCOSTAL UPPER SILL LOCATED BS 827 PLUS 2.5 INCH AT LEVEL S-18R AND WL 200 AFT CARGO BAY IAW SRM 51-10-02, ITEM 9, AND DWG 146A8310, S
Back to JASC 5320