What was found
CORROSION FLOOR FITTING IN AFT ACCESS 205 OUT SIDE (1EA) ON GALLEY 2. SUMMARY OF NRC 00244: FLOOR FITTING IN AFT ACCESS 205 OUT SIDE (1EA) ON GALLEY 2 WAS REPLACED PER SAFRAN CMM 25-32-84 REV 9 DATE JUN 06/24
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FLOOR FITTING IN AFT ACCESS 205 OUT SIDE (1EA) ON GALLEY 2. SUMMARY OF NRC 00244: FLOOR FITTING IN AFT ACCESS 205 OUT SIDE (1EA) ON GALLEY 2 WAS REPLACED PER SAFRAN CMM 25-32-84 REV 9 DATE JUN 06/24