JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023090788443Support Bracket · crackedCRACK BODY STATION 540 SUPPORT BRACKET LH SIDE AT AIR CONDITIONING BAY 2023-490735<[01] REPLACED SUPPORT BRACKET IN 540 BODY STATION AT LH AIR CONDITIONING BAY IAW B737-700 SRM 51-40-02-0G;[02] REPLACED SUPPORT BRACKET IN 540 BODY STATION AT LH AIR CONDITIONINSDR REXA2022090700733Floorbeam · corrodedFS 280 CORROSION NOTED AT APPROXIMATELY RBL 15.0 BETWEEN ANGLE (CAP) AND TOP OF CROSSBEAM, AROUND NUTPLATE HOLE FOR CABIN FLOORBOARD LOCATED AND DRILLED RH FS 280 CROSSBEAM PN: CC670-34094-2 IAW CRJ 900 SRM 51-40-11-001-001-A01. INSTALLED O/B JO-BOLT FASTENSDR SWAA2023090688541Scuff Plate · crackedFWD SERVICE DOOR SCUFF PLATE CRACKED (MARKED)<[01] WELDED CRACK ON RADIUS OF FWD SERVICE DOOR SCUFF PLATE USING AMS 4954 .045' FILLER ROD LOT NUMBER M798431 PER SRM 53-10-15-2R-2 PARAGRAPH 4.B. (3) AND (4). REPAIR WELD STILL REQUIRES A DYE PENETRANT INSPECTIONSDR SWAA2023083188586Scuff Plate · crackedCRACK SCUFF PLATE AFT CORNER AT AFT CARGO COMPARTMENT 2023-508354<[01] TOOL USED DIGITAL CALIPER P/N:500-197-30;S/N:A18229508;DUE DATE:30-OCT-23.;[02] REPAIRED SCUFF PLATE AFT CORNER AT AFT CARGO COMPARTMENT IAW BOEING 737-700 SRM 53-60-15-2R-1 REPAIR 1 AND BASDR LR7A2023081103298Door Sill · crackedDURING SCHEDULED B-3 CHECK UNDER JOB CARD HB5305, FOUND UPPER ENTRY CREW DOOR SILL CRACKED AT FS236, WL195, LBL78. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 1000991145. / PSE# 53-30-12, AD 2012-06-09SDR REXA2022081400629Angle · corrodedSERVICE DOOR ANGLE CLIPS ARE CORRODED FS 319 TO FS 349. LOCATED, DRILLED, AND INSTALLED 4 NEW SERVICEABLE ANGLE CLIPS PN: SH 670-31982-1 IAW CRJ 900 SRM 51-40-11-001-001-A01 AND 51-42-06-001-001-A01.SDR REXA2022081400628Bracket · corrodedSERVICE DOOR PROTECTOR WEBS ARE CORRODED FS 319 TO FS 349. REMOVED AND REPLACED SERVICE DOOR AFT PROTECTOR WEBS IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01SDR REXA2022081400627Bracket · corrodedSERVICE DOOR PROTECTOR WEBS ARE CORRODED FS 319 TO FS 349. REMOVED AND REPLACED SERVICE DOOR FWD PROTECTOR WEBS IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01SDR REXA2022081400626Angle · corrodedSERVICE DOOR LOWER SILL ANGLE AND ATTACH ANGLES FOR LOWER FITTINGS ARE CORRODED FS 319 TO FS 349. LOCATED AND DRILLED NEW DOOR MOUNTING ANGLE IAW CRJ 900 SRM 51-40-11-001-001-A01 AND INSTALLED IAW CRJ SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01 AND 51-42SDR REXA2022081400625Angle · corrodedSERVICE DOOR LOWER SILL ANGLE AND ATTACH ANGLES FOR LOWER FITTINGS ARE CORRODED FS 319 TO FS 349. LOCATED AND DRILLED NEW FLOOR PROTECTOR ANGLE (LOWER SILL ANGLE) IAW CRJ 900 SRM 51-40-11-001-001-A01 AND INSTALLED FLOOR PROTECTOR ANGLE IAW CRJ SRM 51-42-06-00SDR AALA202310056150Fork · wornAIRCRAFT IN BASE MAINTENANCE: 8OVU RACK LEFT HAND LOWER LATERAL FORK END FITTING WORN AT FR 24 AND S32L. REPLACED FORK END FITTING PER EA 347890.SDR AALA202310058821Fork · wornAIRCRAFT IN BASE MAINTENANCE: 8OVU RACK RIGHT HAND LOWER LATERAL FORK END FITTING WORN AT FR 24 AND S32R. REPLACED FORK END FITTING PER EA 347890.SDR SWAA2023092588307Intercostal · crackedFWD CABIN WET AREA FLOOR SUPPORT INTERCOSTAL CRACKED BETWEEN STA 312 AND 328 LBL 48 WL 208.1 MKD DOT<[01] REMOVED AND REPLACED FWD CABIN WET AREA FLOOR SUPPORT INTERCOSTAL BETWEEN STA 312 AND 328 LBL 48 WL 208.1 AS PER SRM 51-40-02-0G-0 AND DWG 141A5410.;[02] SDR SWAA2023092588308Intercostal · crackedFWD CABIN WET AREA FLOOR SUPPORT INTERCOSTAL CRACKED BETWEEN STA 312 AND 328 RBL 35 WL 208.1 MKD DOT<[01] REMOVED AND REPLACED FWD CABIN WET AREA FLOOR SUPPORT INTERCOSTAL BETWEEN STA 312 AND 328 RBL 35 WL 208.1 AS PER SRM 51-40-02-0G-0 AND DWG 141A5400.;[02] SDR SWAA2023091887682Scuff Plate · crackedCRACK ON SCUFF PLATE FWD CORNER ON FWD CARGO COMPARTMENT 2023-506570<[01] TOOL USED DIGITAL CALIPER P/N: 500-193-30; S/N: 0037624; DUE DATE: 13-DEC-23.;[02] TOOL USED: RADIOMETER PHOTOMETER P/N: XRP-3000; S/N: 1753759; CAL DUE DATE: 14-OCT-23;[03] REPAIRED SCUSDR SWAA2023091587683Scuff Plate · crackedCRACK SCUFF PLATE FWD CORNER AT AFT CARGO COMPARTMENT 2023-506571<[01] TOOL USED DIGITAL CALIPER P/N: 500-193-30; S/N: 0037624; DUE DATE; 13/DEC/23.;[02] TOOL USED: RADIOMETER PHOTOMETER P/N: XRP-3000; S/N: 1753759; CAL DUE DATE: 14-OCT-23;[03] REPAIRED SCUFF SDR SWAA2023090788017Unknown · corrodedFWD. CARGO BILGE; L/H T/A HAS LIGHT CORROSION FROM BS.500B-500C.<[01] BLENDED AND REMOVED CORROSION; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-1. .010' MATERIAL REMOVED.;[02] BLENDED AND REMOVED CORROSION; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. .SDR SWAA2023090788024Structure · corrodedFWD. CARGO BILGE; L/H T/A HAS LIGHT CORROSION FROM BS.500C-500D.<[01] BLENDED AND REMOVED CORROSION; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-1. .010' MATERIAL REMOVED. THIS SECTION TO BE REPLACED ON NR# TTG8Q00MRD21.;[02] BLENDED AND REMOVED CORROSION; FSDR SWAA2023090788028Structure · corrodedFWD. CARGO BILGE L/H T/A HAS LIGHT CORROSION FROM BS.500F-500G.SDR REXA2022083000720Intercostal · corrodedMAIN AVIONICS BAY DOOR SURROUND STRUCTURE, INTERCOSTAL BETWEEN FS349 AND FS364 AT STGR 27R CORRODED. LOCATED AND DRILLED NEW INTERCOSTAL P/N SH670-32075-4S, STR27R BETWEEN FS 349 AND FS 364 IAW CRJ-900 SRM 51-40-11-001-001-A01 INSTALLED NEW INTERCOSTAL P/N SSDR REXA2022082900719Intercostal · corrodedMAIN AVIONICS BAY DOOR SURROUND STRUCTURE, INTERCOSTAL BETWEEN FS349 AND FS364 AT STGR 27L CORRODED. LOCATED AND DRILLED NEW INTERCOSTAL STR 27L BETWEEN FS 349 TO FS 364, P/N SH670-32075-3S, IAW CRJ-900 SRM 51-40-11-001-001-A01 INSTALLED NEW INTERCOSTAL P/N SDR REXA2022082400700Floor Support · corrodedCRAWLWAY FLOOR PANEL SUPPORT ANGLE CORRODED AT FS280 BETWEEN STGR26L AND STGR26R INSTALLED NEW CRAWLWAY FLOOR PANEL SUPPORT ANGLE IAW CRJ 900 SRM 51-42-06-001-001-A01 AND CRJ 900 SRM 51-42-21-001-001-A01, P/N CC670-34256-3.SDR SWAA2023082387651Strap · corrodedAFT CARGO FLOOR BOARD STRAP DAMAGED AT 727-I<[01] REMOVED STRAP AND REMOVED CORROSION FROM AREA PER SRM 53-00-53-1A-2 (REMAINING THICKNESS 0.052'). STRAP IS OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED AND REPLACED FLOORBOARD STRAP PER SRM 51-40-02;[03] RSDR HNAA2023081000315Unknown · unknownHN00103350 CORROSION FOUND ON "0" FLOOR BEAM CAP BETWEEN FRM 46-39. INSTALLED NEW SERVICEABLE Y0 FLOORBEAM CAP PN 145-30634-007 BETWEEN FRM39 - FRM47 IAW EMB145 SRM 51-40-08-PR.SDR HNAA2023081000312Unknown · unknownHN00103267 CENTER FLOOR BEAM CAP HAS CORROSION BETWEEN FRM 14 AND FRM 18. INSTALLED NEW SERVICABLE GUSSET P/N 145-22460-015 IAW ERJ-145 SRM 51-40-02-PRSDR REXA2022082200694Spacer · corrodedCROSSBEAM SPACER IS CORRODED AT FS 333, ON THE O/B SIDE OF THE RBL 9 BEAM. REMOVED THE RBL9 O/B CROSSBEAM SPACER AT FS 333 TO FULLY REMOVE ALL CORROSION IAW CRJ-900 51-42-06-001-001-A01. LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE SPACER P/N SH670-32167-3 ASDR DALA2023081506635Unknown · unknownFORWARD CARGO COMPARTMENT DOOR SCUFF PLATE, INSIDE AFT POCKET AREA HAS 2 EA. FASTENER HOLES WITH EVIDENCE OF CORROSION. 'M'. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 001-0234:5321-2015/001 00230 CMOR - COMPLIED WITHSDR DALA2023081406606Unknown · unknownSHIP 0690 CORROSION ON FLOOR STRINGER SUPPORTS (1EAS) AT 10 RBL, STA. 1500-1520 AND (4EA) AT PREVIOUS REPAIRS BTW LBL10.45, LBL 2.9, RBL 2.9, AND RBL 7.5 FROM STA. 1500-1520 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00487: FLOOR STRINGER SUPPSDR I5EA2023081200023Unknown · unknownFOUND CORROSION ON FLOOR SUPPORT AT AFT PIT STA. 767-787 LBL 8.10. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT IAW EO SWA-230610-N629SW FINAL.SDR I5EA2023081200022Unknown · unknownFOUND CORROSION ON FLOOR SUPPORT AT AFT PIT STA. 767-787 LBL 3. REMOVED, FABRICATED AND INSTALL FLOOR SUPPORT IAW EO SWA-230610-N629SW FINAL.SDR I5EA2023081200021Unknown · unknownFOUND CORROSION ON FLOOR SUPPORT AT AFT PIT STA. 767-787 RBL 3. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT IAW EO SWA-230610-N629SW FINAL.SDR I5EA2023081200020Unknown · unknownFOUND CORROSION ON FLOOR SUPPORT AT AFT PIT STA 767-787 RBL 8.10. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT IAW EO SWA-230610-N629SW FINAL.SDR I5EA2023081100014Unknown · unknownFOUND CORROSION ON FLOOR SUPPORT AT AFT PIT STA. 767-787 LBL 12.50, NS AVIATION NON-ROUTINE NUMBER 318:53-870-01-01/024, SERIAL NUMBER 00434. REMOVED, FABRICATED, AND INSTALLED FLOOR SUPPORT IAW EO SWA-23610-N629SW FINALSDR I5EA2023081100012Unknown · unknownFOUND CORROSION ON FLOOR SUPPPORT AT AFT PIT STA. 767-787 LBL 8.10, NS AVIATION NON-ROUTINE NUMBER 318:53-870-01-01/023, SERIAL NUMBER 00432. REMOVED, FABRICATED, AND INSTALLED FLOOR SUPPORT IAW EO SWA-230610-N629SW FINALSDR REXA2022081100616Splice · corrodedSTRINGER 22R SPLICE HAS CORROSION AT F.S.333 INSTALLED NEW STRINGER 22R SPLICE AT F.S.333 IAW CRJ 900 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01SDR REXA2022081100614Splice · corrodedSTRINGER SPLICE AT 21R, FS 477 IS CORRODED . LOCATED, DRILLED AND INSTALLED NEW STR21R SPLICE P/N SH670-33252-1 AT FS477 IAW CRJ-900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01.SDR CALA2023081102487Floor Support · corroded(A3NB-53-3-6321) FLOOR SUPPORT AT Y 1292 CORODDED AT FR 16. DOT# 110-86. W/C:69736 BLENDED AREA FLOOR SUPPORT Y1292 FR 16 IAW SRM 53-11-14-283-007, Y1292 IAW SRM 51-42-11. W/C:69736 EMP:V936636 STA:STENGBFM FOUND TO BE OUT OF LIMITS MAX 0,003,:/ 0,049" (T91554SDR CALA2023081102482Intercostal · corrodedPASSENGER CABIN FLOOR STRUCTURE FWD WET AREA INTERCOSTAL STA328 TO STA344 LBL12 HAS SURFACE CORROSION (REF AAR NR 9204617)SDR REXA2024071600521Seat Track · corrodedSIDE SEAT RAIL AT STGR 15R IS CORRODED BETWEEN FS 744 AND FS 761. REMOVED AND REPLACED SEAT RAIL IAW CRJ900 AMM TASKS 53-00-49-000-801-A13 AND 53-00-49-400-801-A13. FABRICATED PART IAW MHIRJ REO 670-53-00-587 REV C DATED 2023-02-08 REPAIR (B).SDR DALA2024041304395Scuff Plate · corrodedAIRCRAFT 8302, DURING C CHECK IN MSP MTC REPORTED CORROSION UNDER THE SCUFF PLATES SILL, POST BLENDING THE MINIMUM REPORTED THICKNESS WAS LOWER THAN REQUIRED. CORRECTIVE ACTION: TRIM AFT TAB OF NEW SILL (P/N: C02313004007 REF) AT FR29 PER ASRP 51-24-36 AS SHOWSDR SWIA20231027809Unknown · corrodedR/H FLOOR SILL BETWEEN FS310.00 TO FS319.70 HAS CORROSION (MARKED) (C-CHECK RO 10/29/2023) REMOVED CORROSION ON RH FLOOR SILL BETWEEN FS310.00 TO FS319.70. REF CRJ-200 SRM 51-21-06. ORIGINAL THICKNESS OF 0.063". REMAINING THICKNESS OF 0.028" MATERIAL LOSS SDR SWAA2023091987506Support Angle · crackedCRACK ON SUPPORT ANGLE LOCATED BS 695 RBL 24.75 AT PASSENGER CABIN 2023-506534<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112031023; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 25-JAN-24;[02]SDR SWAA2023090787226Intercostal · corrodedPASSENGER CABIN FLOOR INTERCOSTAL CORRODED NEAR LAV MOUNT FITTING AT STA.947+2; LBL 50'. AREA MARKED.<[01] BLENDED CORROSION PER SRM 51-10-02. REMOVED .058' OF MATERIAL. REMAINING THICKNESS .092'. DAMAGE REMOVAL IS OUT OF LIMITS PER SRM 53-70-51-1A-1.;[02] VERSDR SWAA2023090787673Floor Support · crackedWING CENTER SECTION FLOOR PANEL SUPPORT CRACKED AT STA 540 B.L 0 RIGHT 1.0<[01] REMOVED AND REPLACED PANEL BREAK PER SRM 51-40-02.;[02] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1;[03] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023090787672Floor Support · crackedWING CENTER SECTION FLOOR PANEL SUPPORT CRACKED AT STA 540 B.L.0 LEFT 1.0<[01] REMOVED AND REPLACED PANEL BREAK PER SRM 51-40-02.;[02] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1SDR SWAA2023090787227Intercostal · corrodedPASSENGER CABIN FLOOR INTERCOSTAL CORRODED NEAR LAV MOUNT FITTING AT STA.947+2; RBL 50'. REFERENCE TTG8Q00MPV7P FOR ORIGINAL DISCREPANCY.<[01] BLENDED CORROSION PER SRM 51-10-02. REMOVED .040 OF MATERIAL. REMAINING THICKNES IS .110'. DAMAGE REMOVAL IS OUT OF LSDR SWAA2023090787489Web · corrodedAFT CARGO DOOR THRESHOLD WEB STA. 794-847 @ S-25R HAS CORROSION ON UPPER SURFACE.<[01] REMOVED AFT CARGO DOOR SILL WEB PER SRM 51-40-02;[02] DRILLED NEW AFT CARGO DOOR SILL WEB PER SRM 51-40-10;[03] INSTALLED NEW AFT CARGO DOOR LOWER SILL WEB PER SRM 51-40-02;SDR SWAA2023090787667Angle · corrodedAFT CARGO FLOOR STRUCTURE R/H TRANSITION ANGLE STA 767-787+6 HAS CORROSION AROUND VARIOUS FASTENER HOLES.<[01] REMOVED R/H AFT CARGO FLOOR STRUCTURE TRANSITION ANGLE FROM STA.767-787+6 PER SRM 51-40-02.;[02] REMOVED CORROSION AFT CARGO FLOOR STRUCTURE R/H SHIESDR SWAA2023090787664Angle · corrodedAFT CARGO FLOOR STRUCTURE R/H TRANSITION ANGLE STA 727C - 767 HAS CORROSION AROUND VARIOUS FASTENER HOLES. (MARKED)<[01] REMOVED LIGHT SURFACE CORROSION AT R/H TRANSITION ANGLE FROM STA. 727C-767 PER SRM 51-10-02; FOUND TO BE OUT OF LIMITS. MATERIAL REMOVED 0.SDR SWAA2023090787665Angle · corrodedAFT CARGO FLOOR STRUCTURE L/H TRANSITION ANGLE STA 727F-847 HAS CORROSION AROUND VARIOUS FASTENER HOLES. (MARKED)<[01] REMOVED LIGHT SURFACE CORROSION AT L/H TRANSITION ANGLE FROM STA. 727F-847 PER SRM 51-10-02; FOUND TO BE OUT OF LIMITS. MATERIAL REMOVED 0.01
Back to JASC 5320