What was found
FS 280 CORROSION NOTED AT APPROXIMATELY RBL 15.0 BETWEEN ANGLE (CAP) AND TOP OF CROSSBEAM, AROUND NUTPLATE HOLE FOR CABIN FLOORBOARD LOCATED AND DRILLED RH FS 280 CROSSBEAM PN: CC670-34094-2 IAW CRJ 900 SRM 51-40-11-001-001-A01. INSTALLED O/B JO-BOLT FASTENERS AND I/B POST FASTENERS IAW CRJ-900 SRM 51-42-06-001-001-A01 51-42-22-001-001-A01. INSTALLED NEW SERVICEABLE RH CAP ANGLE PN: CC670-34096-2 AT FS 280 IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-13-001-001-A01. LOCATED AND DRILLED NEW SERVICEABLE RH CAP ANGLE PN: CC670-34096-2 AT FS 280 IAW CRJ 900 SRM 51-40-11-001-001-A01. INSTALLED TITANIUM STRIP AT FS 280 BETWEEN RBL 9 TO LBL 9 IAW CRJ 900 SRM 51-42-13-001-001-A01