SDR SWAA2023070565049Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS380+14 BL0 WL208.<[01] REMOVED CRACKED INTERCOSTAL AT FWD CABIN BS380+14 BL0 WL208 IAW SRM 51-40-02;[02] OBTAINED NEW INTERCOSTAL AT FWD CABIN BS380 TO BS 400 BL0 WL208 ; LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG #143A5410SDR SWAA2023070554686Angle · crackedCRACKED INTERCOSTAL AT FWD CABIN BS380+14 LBL13 WL208.<[01] REMOVED ANGLE INTERCOSTAL;FOUND PART HAS NOT SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT; IAW SRM 51-10-02 PARAG 9;[02] LOCATED AND DRILLED NEW ANGLE OF INTERCOSTAL<BR>WITH P/N 143A54190-174 LSDR SWAA2023070565030Gusset · crackedGUSSET IS CRACKED AT STR 19R; BS 500D<[01] VERIFY APPLICABILITY PER SRM 53-30-08-0I-1. NOT ALLOWABLE DAMAGE PARTS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABNLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED GUSSET AT STR 19R BS 500D IAW SRM 51-40-02;[0SDR SWAA2023070565031Gusset · crackedGUSSET IS CRACKED AT STR 19L; BS 500D<[01] VERIFY APPLICABILITY PER SRM 53-30-08-0I-1. NOT ALLOWABLE DAMAGE PARTS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02 STEP 9C;[02] REMOVED GUSSET AT STR 19L BS 500D IAW SRM 51-40-02;[03SDR SWAA2023070565032Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 787+7; LBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 787+7; LBL 22; WL 156; IN AREA OF 1.5' X 1.5' X 0.006' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BE OUT OFSDR SWAA2023070565033Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 767-787; LBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 767-787; LBL 22; WL 156; IN AREA OF 17' X 2.5' X 0.0075' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BE OUSDR SWAA2023070565034Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 747-747+16; LBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 747-747+16; LBL 22; WL 156; IN AREA OF 14' X 2' X 0.008' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BESDR SWAA2023070565035Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 747-747+16; RBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 747-747+16; RBL 22; WL 156; IN AREA OF 14' X 1.5' X 0.08' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BSDR SWAA2023070565036Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 727E+14; LBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 727E+14; LBL 22; WL 156; IN AREA OF 1' X 1' X 0.006' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BE OUT OFSDR SWAA2023070554681Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 727E+2; LBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 727E+2; LBL 22; WL 156; IN AREA OF 2' X 1' X 0.006' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BE OUT OF LSDR SWAA2023070565037Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 727E-747; RBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 727E-747; RBL 22; WL 156; IN AREA OF 17' X 2' X 0.009' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BE OUTSDR SWAA2023070565038Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 727D-727E; LBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 727D-727E; LBL 22; WL 156; IN AREA OF 17' X 1.5' X 0.008' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BESDR SWAA2023070565040Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 727D-727E; RBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 727D-727E; RBL 22; WL 156; IN AREA OF 15' X 1.5' X 0.0065' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BSDR SWAA2023070565041Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 727C-727C+12; LBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 727C-727C+12; LBL 22; WL 156; IN AREA OF 11' X 1.5' X 0.008' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUNDSDR SWAA2023070565042Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 727C-727C+12; RBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 727C-727C+12; RBL 22; WL 156; IN AREA OF .5' X 1' X 0.007' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TSDR SWAA2023070565045Sidewall Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 727B-727C; RBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 727B-727C; RBL 22; WL 156; IN AREA OF 17' X 1' X 0.008' DEEP ORIGINAL MATERIAL THICKNESS 0.040' FOUND TO BE OSDR SWAA2023070554673Web · corrodedSUB THRESHOLD IS CORRODED AT BS 847-787+11; RBL 26; WL 162<[01] VERIFIED APPLICABILITY PER REF SRM 53-60-15-0I-1 AND SRM 53-60-15-1A-1 <BR><BR>REMOVED CORROSION ON SUB THRESHOLD AT BS 847-787+11; RBL 26; WL 162 L=1 W=1 . ORIGINAL MATERIAL THICKNESS IS .050'' ASDR SWAA2023070554690Support · corrodedFLOOR TO SIDE WALL SUPPORT HAS CORROSION AT BS 727B+10-727B+16; LBL 22; WL 156<[01] REMOVED CORROSION FROM AFT CARGO BAY FLOOR TO SIDE WALL SUPPORT ANGLE BS 727B+10-727B+16; LBL 22; WL 156; IN AREA OF 6' X 1.5' X 0.0075' DEEP ORIGINAL MATERIAL THICKNESS 0.040'SDR SWAA2023070364979Structure · corrodedCORROSION FLOOR STRUCTURE LOCATED BS986.5 WL208.1 AND LBL43 AT AFT GALLEY AREA 2023-360184<[01] ULTRASONIC EQUIPMENT USED P/N: 45MG; S/N: 130063701 AND DUE DATE: 16-JUN-23.;[02] TOOL USED: ULTRASONIC THICKNESS GAGE; P/N: 45MG; S/N:221860711; CAL DUE DATE:07-NOSDR SWAA2023070354662Bracket · corrodedCORROSION SUPPORT BRACKET LOCATED BS344 WL208.1 AND LBL58 AT FWD GALLEY AREA 2023-360198<[01] REPLACED SUPPORT BRACKET LOCATED BS344 WL208.1 AND LBL58 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-40-02;[02] CORRECTED STEP 1<BR>REPLACED SUPPORT BRACKET LOCATED BS34SDR SWAA2023070354665Bracket · corrodedCORROSION SUPPORT BRACKET LOCATED BS312 WL208.1 AND LBL55 AT FWD GALLEY AREA 2023-360197<[01] REPLACED SUPPORT BRACKET LOCATED BS312 WL208.1 AND LBL55 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-40-02;[02] CORRECTED STEP 1<BR>REPLACED SUPPORT BRACKET LOCATED BS31SDR SWAA2023070354478Structure · corrodedCORROSION FLOOR STRUCTURE LOCATED BS986.5 WL208.1 AND RBL43 AT AFT GALLEY AREA 2023-360185<[01] ULTRASONIC EQUIPMENT USED P/N: 45MG; S/N: 130063701 AND DUE DATE: 16-JUN-23.;[02] TOOL USED: EDDY CURRENT EQUIPMENT; P/N: NORTEC600D; S/N : 210138103; CAL DUE DATE:SDR SWAA2023070354479Structure · corrodedCORROSION FLOOR STRUCTURE LOCATED BS986.5 WL208.1 AND LBL43 AT AFT GALLEY AREA 2023-360184<[01] ULTRASONIC EQUIPMENT USED P/N: 45MG; S/N: 130063701 AND DUE DATE: 16-JUN-23.;[02] TOOL USED: ULTRASONIC THICKNESS GAGE; P/N: 45MG; S/N:221860711; CAL DUE DATE:07-NOSDR SWAA2023070364978Structure · corrodedCORROSION FLOOR STRUCTURE LOCATED BS986.5 WL208.1 AND RBL43 AT AFT GALLEY AREA 2023-360185<[01] ULTRASONIC EQUIPMENT USED P/N: 45MG; S/N: 130063701 AND DUE DATE: 16-JUN-23.;[02] TOOL USED: EDDY CURRENT EQUIPMENT; P/N: NORTEC600D; S/N : 210138103; CAL DUE DATE:SDR SWAA2023062964984Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND RBL31 AT FWD GALLEY AREA 2023-360190<[01] REPLACED NEW WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND RBL31 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWINGSDR SWAA2023062964983Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND LBL46 AT FWD GALLEY AREA 2023-360189<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND LBL46 AT FWD GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-40-02. SRM 51-SDR SWAA2023062964982Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS277 TO BS294.5 AND BL0 AT FWD GALLEY AREA 2023-360191<[01] REPLACED WEB - INTERCOSTAL AND FASTENERS FLOOR STRUCTURE LOCATED BTW BS277 TO BS294.5 AND BL0 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG SDR SWAA2023062954666Floor Support · corrodedCORROSION WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS294.5 TO BS312 ; LBL11 AND WL208.1 AT FWD GALLEY AREA 2023-360192<[01] REPLACED WEB-INTERCOSTAL FLOOR STRUCTURE BTW BS294.5 TO BS312 LBL11 AND WL208.1 AT FWD GALLEY AREA I.A.W. B737-700 SRM 51-10-02 ITEM 9 SDR SWAA2023062954664Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND RBL31 AT FWD GALLEY AREA 2023-360190<[01] REPLACED NEW WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND RBL31 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWINGSDR SWAA2023062954663Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND LBL46 AT FWD GALLEY AREA 2023-360189<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND LBL46 AT FWD GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-40-02. SRM 51-SDR SWAA2023062954661Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS277 TO BS294.5 AND BL0 AT FWD GALLEY AREA 2023-360191<[01] REPLACED WEB - INTERCOSTAL AND FASTENERS FLOOR STRUCTURE LOCATED BTW BS277 TO BS294.5 AND BL0 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG SDR SWAA2023062954100Sidewall Support · damagedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS DISBONDED NUTPLATE AT STA 727D+8; WL 155.5; LBL 21.<[01] WORK TO BE COMPLETED BY CUST SYSTEM ID : TTG8Q00LC60R<BR>THIS FLOOR TO SIDEWALL SUPPORT IS REPAIRED BY REPLACEMENT;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023062054642Shield · corrodedCORROSION ON SHIELD LOC. BS767 TO BS794.3 AT LEVEL STR 25R AFT CARGO COMPARTMENT 2023-361035<[01] REPLACED SHIELD AND FASTENERS LOCATED ON BS 767 TO BS 794.3 AT LEVEL STR 25R AFT CARGO COMPARTMENT IAW B737-700 SRM 51-40-02-0G-0 AND DWG 146A0081 SHEET 19 REV A.SDR SWAA2023062054644Support · corrodedCORROSION SUPPORT ZEE LOC. BTW BS 727 TO BS 847 AT LEVEL STR 25L AFT CARGO COMPARTMENT 2023-361042<[01] EQUIPMENT P/N 35DLPLUS; S/N 120398603; DUE DATE 07-NOV-23 WAS USED;[02] REPAIRED SUPPORT ZEE LOC. BTW BS 727 TO BS 847 AT LEVEL STR 25L AFT CARGO COMPARTMENSDR REXA2022062000372Frame · corrodedFUSELAGE FRAME F.S.250 BETWEEN STGR 26L AND 26R IS CORRODED. REPAIRED IAW ENDEAVOR AIR EA CRJ953-14013SDR REXA2022062000371Frame · corrodedFUSELAGE FRAME F.S.533 BETWEEN STGR 26L TO 26R IS CORRODED REPAIRED IAW ENDEAVOR AIR EA CRJ953-14013SDR F3LA2023061900081Door Sill · corrodedDISCREPANCY: REFERENCE AIRBORNE/PEMCO N/R 14018.0238 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. L2 DOOR, DOOR SILL FASTENERS CORRODED
CORRECTIVE ACTION: EVALUATED 2EA NUT PLATE HOLES AT L2 DOOR AFT DOOR SILL AFTER FURTHER EVALUATION FOUND OUTSDR F3LA2023061900080Shear Plate · corrodedDISCREPANCY: REFERENCE AIRBORNE/PEMCO N/R 14018.0237 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULE MX. R/H AFT GALLEY SHEAR PLATE HAS SURFACE CORROSION
CORRECTIVE ACTION: REMOVED & REPLACED MAIN CABIN FLOOR STRUCTURE R/H FR69-70 SHEAR PLATE IAW A320 SDR F3LA2023061600079Shear Plate · crackedDISCREPANCY: REFERENCE AIRBONRE/PEMCO N/R 14018.0236 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX/ L/H AFT GALLEY SHEAR PLATE CRACKED
CORRECTIVE ACTION: REMOVED & REPLACED MAIN CABIN FLOOR STRUCTURE L/H FR69-70 SHEAR PLATE IAW A320 SRM 51-72-11SDR SCNA20230606176Web · wornDEFECT NR00129: E&E COMPARTMENT DOOR CUTOUT FRAME LH WEB HAS WEAR MARKS. - - - RESOLUTION: REMOVED AND REPLACED E&E BAY DOOR CUTOUT LH WEB WITH NEW LOT # 5047744 IAW B737 SRM 51-40-02-06-0 DWG # 141A0650.SDR DALA2023060504496Unknown · unknown(LOG 2793411) FLOOR STRUCTURE BEAM @ STA 947 HAS SEVERAL AREAS OF CORROSION FROM LBL25 - RBL25, WL210. REMOVED DAMAGE AND REPAIRED IAW B737 SRM 53-00-51-2R-1.SDR DALA2023060504495Channel · punctured(LOG 2793348) FORWARD CARGO BAY R/H Z CHANNEL HAS A PUNCTURE AT 500B. REMOVED AND REPLACED R/H ZEE CHANNEL FROM STA 500A TO STA 500B +10 IAW B737 SRM 51-40-02, B737 SRM 53-00-53-2R PROCEDURE 5 AND BOEING DWG# 143A7500 AND DWG# 143A7501.SDR DALA2023060104385Unknown · unknownCRACK ON CUSP MEMBRANE (WEB) X=44 AND STA 636 AT CPAX. SUMMARY OF NRC 00431: CRACK ON CUSP MEMBRANE (WEB) X=44 AND STA 636 AT CPAX WAS REPAIRED PER B717-200 SRM 55-00-55-2R PROCEDURE 4 PAR 5 FIG 217. (LP #2793591)SDR DALA2023060104384Unknown · unknownCORROSION ON FLOOR SUPPORT RBL 54 STA Y=1050 AND Y=1054 AT CPAX CABIN. SUMMARY OF NRC 00374: CORROSION LEVEL 2. FLOOR SUPPORT RBL 54 STA Y=1050 AND Y=1054 AT CPAX CABIN WAS REPLACED PER DWG 9981474 REV L AND B717-200 SRM 51-41-05-0G. (LP #2793392)SDR IPXA2023053193342Strap · damagedINSPECTION TYPE:CAA INSP. STIFFINER IN AFT ACCESSORY COMPT AT FR 86 IS DAMAGEDREPLACED STRAP IAW SRM 51-40-21 AND SRM 53-19-18SDR IPXA2023053193338Strap · damagedINSPECTION TYPE:CAA INSP. STIFFINER DAMAGED IN AFT ACC COMPREPLACED STRAP IAW SRM 51-40-21 AND SRM 53-19-18SDR JR2R20230531760Floor Support · crackedFLOOR BOARD SUPPORT CLIP CRACKED AT FR86 LBL24SDR SWAA2023070668464Support · crackedMAIN CABIN CENTER WING FLOOR SUPPORT BREAK CRACKED AT LBL 1 STA 540 MKD DOT<[01] INSTALLED NEW MAIN CABIN CENTER WING FLOOR SUPPORT BREAK AT LBL 1 STA 540 AS PER SRM 51-40-02-0G-0/ DRW 143A0060.;[02] VERIFIED ALL STEPSSDR SWAA2023070353513Bracket · crackedAFT CARGO COMPARTMENT AT THE 727 BULKHEAD HAS BROKEN BRACKET AT STA: 727; WL:14.5; BL:3.5 CORRECTION WL: 163 RBL:3.5<[01] MEASURMENT UPDATE; NO ALLOWABLE DAMAGE LIMIT FOUND IN SRM. PART TO BE REPAIRED BY REPLACMENT;[02] REMOVED CRACKED 727 BULKHEAD BRACKET AT SDR SWAA2023070354094Supercharger · corrodedAFT CARGO RIGHT FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT: STA:727B+14; 727C+14; 727C+6; 727D+3; 727D+8; 727D+11; 727D+14; 727D+18; 727E+2; 727E+6 WL: 156; RBL:20 T0 22<[01] VERIFIED APPLICABILITY OF SRM 53-60-53-01-2 IDENTIFICATION 2 AND SRM 53-00-53-1A-2 AL