What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND LBL46 AT FWD GALLEY AREA 2023-360189<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND LBL46 AT FWD GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-40-02. SRM 51-10-02 ITEM 9. DWG 141A5400 REV-.;[02] CORRECTED STEP 1<BR>REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND LBL46 AT FWD GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-40-02. SRM 51-10-02 ITEM 9. DWG 141A5400 REV-. SEE INDIVIDUAL SIGN OFF BELOW.;[03] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS312 TO BS328 AND LBL46 AT FWD GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-40-02. SRM 51-10-02 ITEM 9. DWG 141A5400 REV-. ITEM RII SEE INDIVIDUAL SIGN OFF BELOW.