SDR IPXA2022052582481Floor Panel · damagedINSPECTION TYPE:C PNL 251VJ BROKEN FABBED IAW SREO A300-5320-40552-BSDR IPXA2022052582480Floor Panel · damagedINSPECTION TYPE:C PNL 252LJ BROKEN FABBED IAW SREO A300-5320-40552-BSDR IPXA2022052582479Floor Panel · damagedINSPECTION TYPE:CPNL 242LH CRACKED FABBED IAW SREO A300-5320-40552-BSDR IPXA2022052582478Floor Panel · damagedINSPECTION TYPE:C PNL 241GN BROKEN FABBED IAW SREO A300-5320-40552-BSDR IPXA2022052582477Floor Panel · damagedINSPECTION TYPE:C PNL 231SG BROKEN FABBED IAW SREO A300-5320-40552-BSDR SWAA2022052597672Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT RBL30 FWD GALLEY AND LAV 2022-207226 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT RBL30 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 SRM 51-40-02 AND DWG 14SDR SWAA2022052597679Web · crackedCRACK INNER CHORD LOCATED BS303.9 AT LBL55 AT FWD GALLEY AREA 2022-207235 / [01] REPLACED INNER CHORD LOCATED BTW BS 360 AND BS 270 AT LBL55 AT FWD GALLEY AREA I.A.W B737-700 SRM 51-40-02 DWG:141A8110 SHEET:9 REV:A P/N: 654A0004-1073 P.O: 2023000639 SEE INDIVISDR SWAA2022052597680Web · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL46 FWD GALLEY AND LAV 2022-207233 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL46 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 SRM 51-40-02 AND DWG 14SDR SWAA2022052597681Web · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS277 TO BS294.5 AT BL0 FWD GALLEY AND LAV 2022-207232 / [01] REPLACED NEW WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS277 TO BS294.5 AT BL0 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET 20 SDR IPXA2022052082287Floor Panel · delaminatedINSPECTION TYPE:A300MDC FLOOR PANEL 242TK DELAMINATEDREPAIRED MDC FLOOR PANEL 242TK AS NEEDED IAW EO NO:A300-5320-42722-FSDR IPXA2022052082286Floor Panel · delaminatedINSPECTION TYPE:A300MDC FLOOR PANEL 242BQ DELAMINATEDREPAIRED MDC FLOOR PANEL 242BQ AS NEEDED IAW E.O NO:A300-5320-42722-FSDR IPXA2022052082284Floor Panel · puncturedINSPECTION TYPE:A300MDC FLOOR PANEL 232TG HAS PUNCTURESREPAIRED MDC FLOOR PANEL 232TG AS NEEDED IAW EO NO:A300-5320-42722-FSDR IPXA2022052082283Floor Panel · crackedINSPECTION TYPE:A300MDC FLOOR PANEL 242DQ CRACKEDREPAIRED MDC FLOOR PANEL 242DQ AS NEEDED IAW E.O NO:A300-5320-42722-FSDR IPXA2022052082281Floor Panel · noneINSPECTION TYPE:A300MDC FLOOR PANEL 241TK HAS HOLEREPAIRED MDC FLOOR PANEL 241TK AS NEEDED IAW E.O NO:A300-5320-42722-FSDR IPXA2022052082279Floor Panel · brokenINSPECTION TYPE:A300MDC FLOOR PANEL 231NJ BROKENREPAIRED MDC FLOOR PANEL 231NJ AS NEED IAW E.O NO:A300-5320-42722-FSDR IPXA2022052082278Floor Panel · puncturedINSPECTION TYPE:A300MDC FLOOR PANEL 232LF HAS PUNCTUREREPAIRED MDC FLOOR PANEL 232LF AS NEED IAW E.O NO:A300-5320-42722-FSDR IPXA2022052082291Floor Panel · delaminatedINSPECTION TYPE:A300MDC FLOOR PANEL 242YK DELAMINATEDREPAIRED MDC FLOOR PANEL 242TK AS NEEDED IAW AE.O NO:A300-5320-42722-FSDR IPXA2022052082290Floor Panel · crackedINSPECTION TYPE:A300MDC FLOOR PANEL 242PK CRACKEDREPAIRED MDC FLOOR PANEL 242PK AS NEEDED IAW EO NO A300-5320-42722-FSDR SWAA2022051297633Housing · brokenR/H AFT OVER WING EXIT STRAP HOUSING IS BROKEN. / [01] REMOVED AND REPLACED R/H OVER WING EXIT STRAP HOUSING IAW AMM USE OF STANDARD INDUSTRY PRACTICES;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2022051097543Gusset · crackedFWD CARGO COMP. L/H SIDE STR 19L BETW. STA 500C THRU 500D GUSSET CRACKED / [01] REMOVED GUSSET FROM FWD CARGO STA 500C-500D STR 19L PER B737-700 SRM 51-40-02-0G-0.;[02] LOCATED AND DRILLED NEW GUSSET PER B737-700 SRM 51-10-02-0G-0.;[03] VERIFIED STEP #1.;[04] SDR SWAA2022050397452Threshold · corrodedUPON REMOVAL OF THE AFT CARGO ENTRY THRESHOLD; FOUND SEVERAL AREAS OF CORROSION ON THE MOUNTING SURFACE. / [01] REMOVED AFT CARGO WEB 146A8123U25 PER SRM 51-40-01;[02] ADDED REFERENCE INFO;[03] DRILLED UP NEW AFT. CARGO WEB. REF. SRM. 51-40-05;[04] OK TO INSTASDR REXA2022061401228Seat Track · corrodedL/H CABIN SEAT TRACK AT LBL 9.00 BETWEEN FS. 379.00 AND FS 453.OO IS CORRODED AT FOWARD END. INSTALLED NEW SEAT TRACK FROM FS. 379.00TO FS. 459.00 LBL 9.00 IAW CRJ 900 AMM 53-00-49-400-801-A07SDR REXA2022061401227None · corrodedL/H SIDE RAIL AT FS. 629.00 TO 650 HAS SURFACE CORROSION INSTALLED NEW L/H SIDE SEAT RAIL FROM FS. 573.OO TO FS. 661.00+16" WL 85.25 IAW CRJ 900 AMM 53-00-49-400-801-A07SDR REXA2022052701013Splice · corrodedSTR19R SPLICE IS CORRODED BETWEEN FS469 AND FS477 REMOVED AND REPLACED JOINT PIECE AT FS477 IAW CRJ900 SRM 51-42-06-001-001-A01.SDR REXA2022052701011Cleat · corrodedFORWARD SIDE OF F.S. 265.00 FRAME STGR 27, SPRING CLEAT FOUND TO BE CORRODED. REMOVED AND REPLACED CLEAT I.A.W. BOMBARDIER CRJ900 SRM 51-42-06-001-001-A01.SDR REXA2022052600998Angle · corrodedBELOW THE FLOOR AT FS 280 FLOOR BOARD NUTPLATE ANGLE IS CORRODED. REMOVED AND REPLACED ANGLE ASSEMBLY IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, AND 51-42-21-001-001-A01. ORANGE TAPE WAS REMOVED.SDR REXA2022052600984Seat Track · corrodedCORROSION ON FLOOR SEAT TRACK FS985 - FS1000, LBL9 REMOVED, FABRICATED, AND INSTALLED SEAT TRACK IAW CRJ 900 SRM 53-00-49-201-002-A01 AND AMM 53-00-49-000/400-801-A19.SDR HNAA2022052600211Floor Support · corrodedE914503 - GALLEY LH INBD SEAT TRACK #1 IS CORRODED .... RAR GALLEY LH INBD SEAT TRACK #1 IAW EMB 145 AMM 53-01-06SDR SWAA2022052597404Floor Panel · delaminatedFLOOR ACCESS PANEL 241AF DELAMINATED / [01] FABRICATED NEW CABIN PASSENGER CABIN FLOOR ACCESS PANEL 241AF IN REF B737-700 SRM 53-00-50-2R-0 AND DWS #S 143A5810 AND 143A5800;[02] VERIFIED STEP 1SDR SWAA2022051097301Shield · corrodedFWD CARGO COMP.R/H SIDE SHIELD BETWEEN STA 500 THRU 500AHAS CORROSION / [01] REMOVED CORROSION AT FWD CARGO AFT SHIELD BETW. STA 500 THRU 500A R/H SIDE PEER B737-700 SRM 51-10-02-0G-0 (WORKED BY HUMBERTO MEDINA 26340);[02] VERIFIED STEP 1.;[03] PERFORMED UT THSDR REXA2022050300772Frame · corrodedF.S. 265.00 FRAME IS CORRODED BETWEEN STGR 27 TO STGR 26R. CA: COMPLIED WITH ENDEAVOR EA CRJ953-12983, REV. B DATED 4/23/22.SDR SWAA2022052397186Stiffener · corrodedCORROSION ON STIFFENER LOCATED BTW BS 312 TO BS 328 FLOOR STRUCTURE LBL 11 WL 208.1 FWD GALLEY AREA 2022-211494 / [01] REPLACED STIFFENER LOCATED BTW BS 312 TO BS 328 FLOOR STRUCTURE LBL 11 WL 208.1 FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141ASDR SWAA2022052397178Intercostal · corrodedCORROSION ON INNER CHORD LOCATED ON BS 328 AT LEVEL OF FLOOR STRUCTURE RBL 64 WL 208.1 FWD GALLEY AREA 2022 211502 / [01] TOOL USED ULTRASONIC EQUIPMENT PN: 35DL; SN: 091419910; DUE DATE: 26 JAN 23.;[02] REPLACED INNER CHORD AND FASTENERS LOCATED ON BS 259 TO SDR SWAA2022052397179Bracket · corrodedCORROSION ON SUPPORT BRACKET LOCATED ON BS 312 AT LEVEL FLOOR STRUCTURE LBL 64 WL 208.1 FWD GALLEY AREA 2022-211503 / [01] REPLACED SUPPORT BRACKET LOCATED ON BS 312 AT LEVEL FLOOR STRUCTURE LBL 64 WL 208.1 FWD GALLEY AREA I.A.W SRM 51-40-02 AND SRM 51-10-02 ISDR SWAA2022052397180Angle · corrodedCORROSION ON SUPPORT ANGLE LOCATED BTW BS 312 TO BS 328 RBL 64 AND WL 208.1 FWD GALLEY AREA 2022-211504 / [01] REPLACED SUPPORT ANGLE AND FASTENERS LOC. BS 294 TO BS 328 RBL 64 AND WL 208.1 FWD GALLEY AREA; PART NUMBER USED 141A8312-5 PO 2022-143019 IAW B737-7SDR SWAA2022051997200Intercostal · corrodedCORROSION ON INNER CHORD LOCATED BTW BS 967 TO BS 986.5 AT LEVEL FLOOR STRUCTURE RBL 64 AND WL 208.1 AFT GALLEY AREA 2022-211515 / [01] TOOL USED ULTRASONIC EQUIPMENT PN: 35DL; SN: 091419910; DUE DATE: 26 JAN 23.;[02] REPLACED INNER CHORD LOCATED BETWEEN BS887SDR SWAA2022051997183Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS277 TO BS294.5 AT BL0 FWD GALLEY AND LAV 2022-211489 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOC. BS 277 TO BS 294.5 AND LBL 0 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02; 51-40-02 AND DRAWING 141A54SDR SWAA2022051997177Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL47 FWD GALLEY AND LAV 2022-211492 / [01] REPLACED WEB-INTERCOSTAL AND FASTENERS FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL47 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM SDR SWAA2022051997187Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT RBL31 FWD GALLEY AND LAV 2022-211499. REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT RBL31 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 AND DRAWING 141A5400 REV: - SEE INDISDR SWAA2022051997188Web · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS344 TO BS360 AT RBL11 FWD GALLEY AND LAV 2022-211498 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS344 TO BS360 AT RBL11 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141A5400 REV -<SDR SWAA2022051997190Web · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS344 TO BS360 AT LBL11 FWD GALLEY AND LAV 2022-211496 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS344 TO BS360 AT LBL11 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141A5400 REV A<SDR SWAA2022051997191Web · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS344 TO BS360 AT BL0 FWD GALLEY AND LAV 2022-211491 / [01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOC. BS 344 TO BS 360 AND LBL 0 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02; 51-40-02 AND DRAWING 141A5400; SDR SWAA2022051297160Support Bracket · crackedFWD CARGO SIDEWALL SUPPORT BRACKET;SHOWS INB SURFACE CRACKED AT B.S.540D STR 18L MKD / [01] REMOVED AND REPLACE SUPPORT BRACKET AT FWD CARGO STA 500D STR 18L IRW SRM 51-40-02;[02] VERIFIED 1;COMPLETESDR SWAA2022051297161Support Bracket · crackedFWD CARGO SIDEWALL SUPPORT BRACKET;SHOWS INB SURFACE CRACKED AT B.S.540D STR 18R MKD / [01] REMOVED AND REPLACED FWD CARGO SUPPORT BRACKET AT STA 500D STR 18R IRW B737-700 SRM 51-40-02;[02] VERIFIED 1;COMPLETESDR SWAA2022042697030Floorboard · crackedAFT CARGO BIN FLOORBOARD CRACK FOUND / [01] FOUND 2.8' CRACK AT STA 770 ON CARGO FLOOR CENTERLINE. C/W INTERIM REPAIR PER SRM 53-00-53-1A-1. VISUAL REINSPECT AT 400 CYCLES. REPLACEMENT OR REPAIR AT 4000 CYCLES.SDR IPXA2022042381417Structure · corrodedINSPECTION TYPE:SEG2WING TO BODY STRUCTURE AT FS 1180-1240 RBL 57.5 HAS INTERGRANULAR CORROSION.REMOVED CORRODED T CHORD SECTION AND INSTALLED REPLACEMENT T CHORD SECTION USING BAC1505-100403 PER TRAVELER# T22/1612520 AND SRM 51-40-02-0GSDR 2024FA0000155Stiffener · crackedAFT FUSELAGE LOWER SKIN STIFFENER FOUND CRACKED. REPLACED WITH NEW STIFFENER.SDR REXA2022060600973Splice · corrodedPANEL 191AB SPLICE JOINT PLATE CORRODED IN MULTIPLE AREAS WITH A DEPTH OF .016". REMOVE AND REPLACE SPLICE JOINT.SDR SWAA2022051296877Floor Support · corrodedCORROSION ON FLOOR SUPPORT STA 950; LBL 23; WL 208. / [01] EVALUATED CORROSION ON FLOOR SUPPORT STA 950; LBL 23; WL 208. FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS PER SRM 53-70-51-1A-1; SRM 51-10-02-0G-0 REPLACEMENT OF PART IS APPLICABLE.;[02] VERIFIED NO SRMSDR SWAA2022051296502Sidewall Support · corrodedAFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 727G+3 TO 847 LBL 21 WL 156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 767+5 LBL 21 WL 156; FOUND 0.015 REMOVED FROM ORIG 0.040 IN NUMEROUS 1'X1' AREAS; FOUND TO
Back to JASC 5320