What was found
FWD CARGO COMP.R/H SIDE SHIELD BETWEEN STA 500 THRU 500AHAS CORROSION / [01] REMOVED CORROSION AT FWD CARGO AFT SHIELD BETW. STA 500 THRU 500A R/H SIDE PEER B737-700 SRM 51-10-02-0G-0 (WORKED BY HUMBERTO MEDINA 26340);[02] VERIFIED STEP 1.;[03] PERFORMED UT THICKNESS INSP ON REWORKED AREA IAW B737 NDT P4 51-00-00 PROC.3 ; MIN THK. NOTED 0.016'<BR>TOOL USED : OLYMPUS 27MG B/C 172139 04/23;[04] AFTER REWORKED AREA AT FWD CARGO COMP. R/H SIDE STR 26R BETW. STA 500 THRU 500A FOUND OUT LIMITS PER B737-700 SRM 53-00-53-1A-2.ORIG.MAT=.032' MAT.REMOVED=.016';MAT.REMAINING=.016';[05] VERIFIED STEP 4.;[06] REPLACED FWD CARGO COMP. R/H SHIELD FROM STA 500 TO 500A PER SRM 51-40-02-0G-0. THIS SHIELD WILL BE INSTALLED ON FWD CARGO MOC TASK CARD #TTG8Q004E4M4;[07] VERIFIED STEP #6.