SDR SWAA2021102730626None · crackedAFT CARGO BAY R/H SIDEWALL CAP STRIP CRACKED BS 790 STR 18 - STR 25 ; / [01] REPLACED CRACKED AFT CARGO BAY R/H SIDEWALL CAP STRIP AT BS 790; STR 18R - 25R WITH NEW PART S/N / LOT# 1421820-3 IAW AMM 25-52-06-400-801 PAR. 3.D. (9)<BR><BR>ATS SCREW GUN ATS2246 SSDR YENA2021102000696Shear Tie · corrodedDURING HEAVY MAINTENANCE, CORROSION: SHEAR CLIP FR87 STR27-28R ; REF TOMX NR 00421: R & R SHEAR CLIP FR87 STR27-28R IAW SRM 51-41-02 AND 51-43-01.SDR YENA2021102000689Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION: PAX CABIN FLOOR WEB FR87-88 Y=300 - Y=1000 ; REF TOMX NR 00419: R & R PAX CABIN FLOOR WEB @ FR87-88 Y=300 - Y=1000 IAW SRM 51-42-01, 51-42-02, AND 51-43-03.SDR YENA2021102000686Skin · dentedDURING HEAVY MAINTENANCE, FUSELAGE/ CENTER FUSELAGE III/ LOWER SKIN BTWN FR 83-84 & STGR 23L-24L/ DENT- PERMANENT REPAIR. CLASSIFIED AS MAJOR REPAIRSDR SWAA2021102031168None · corrodedLH TRANSITION ANGLE HAS CORROSION AROUND FASTENER HOLE UPPER SURFACE AT STA 747+14. REMOVED SURFACE CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-60-51-1A-1. REMOVED AND REPLACED ANGLE ON TASK CARD 5360-E-16462-NG.SDR SWAA2021102031183None · corrodedLH TRANSITION ANGLE HAS CORROSION AROUND FASTENER HOLE UPPER SURFACE AT STA 747+10. REMOVED SURFACE CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-60-51-1A-1. REMOVED AND REPLACED ANGLE ON TASK CARD 5360-E-16462-NG.SDR SWIA202201063643Floor Support · corrodedFLOOR BEAM AT LBL27 HAS MULTIPLE SPOTS OF CORROSION FROM FS1000 TO FS1098 (C CHECK RO 01-05-2022) REPAIRED FLOOR BEAM FROM FS 1000- TO FS 1098 AT LBL 27 IAW REO 670-53-61-2003 REV --, DATED 2021-11-12, MAJOR REPAIR TASK CARD 51-900-1002-SKY, AND COMPLETED SDR AALA202112067708Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO TRANSITION PANEL LEFT HAS CORROSION SPOTS AT STATION 500E TO 500F. INSTALLED NEW LEFT TRANSITION PANEL AND SPLICES STA408-STA500E+10 PER SRM 53-00-53-2R.SDR AALA202112068979Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO TRANSITION PANEL RIGHT HAS CORROSION SPOTS AT STA 500G TO 500H. REPLACED RIGHT TRANSITION PANEL PER SRM 53-00-53-2R-5.SDR AALA202112060382Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO TRANSITION PANEL RIGHT HAS CORROSION SPOTS AT STATION 500 E TO 500 F. RIGHT TRANSITION PANEL REPLACED PER SRM 53-00-53-2R-5.SDR AALA202112033944Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=1.00 IN, W=2.00 IN, D=0.022 IN, ON FORWARD CARGO LEFT HAND TRANSITION PANEL LOCATED BETWEEN STA 408 AND STA 500E AT S26L. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R PROCEDURE 5 AND AARD 51-00-05-1A.SDR AALA202112037780Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION MEASURING L=0.5 IN, W=0.5 IN, D=0.038 IN, ON FORWARD CARGO LEFT TRANSITION PANEL LOCATED BETWEEN STA 408 AND STA 500E AT S26L. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R PROCEDURE 5 AND AARD 51-00-05-1ASDR REXA2021111700993Splice Angle · corrodedFS 280 CROSSBEAM LOWER SPLICE ANGLE CORRODED AND BLOWN UP HOLES. - FOUND SPLICE ANGLE TO BE OUT OF LIMITS PER CRJ 900 SRM 53-00-00-101-001-A01, LOCATED, DRILLED & INSTALLED & PAINTED SERVIEABLE SPLICE ANGLE IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-06-001-0SDR REXA2021111700990Joint · corrodedJOINT ANGLE/SPLICE AT STR 25R FS 333 CORRODED. - LOCATED, DRILLED & REPLACED JOINT ANGLE SPLICE IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-25-00-001-001-A01, 51-14-06-001-001-A01.SDR REXA2021111600966Stringer · crackedSTR 3L AT FS 280 IS CRACKED - COMPLIED WITH ENDEAVOR AIR E.O. R53568 REV 5. REFERENCE JOB 81520045, OP 5344 FOR COMPLETION OF THIS TASK. WVAC EMP # 583111SDR SWAA2021111530900Angle · crackedCRACK ANGLE - CLIP LOCATED BS 400 AND STRINGER 26L AT FWD CARGO COMPARTMENT ; 2021-461990 / [01] TOOL USED DIGITAL CALIPER<BR>P/N: 500-172-30 S/N: 15237811 DUE DATE:11 MAY 22; [02] REPLACED ANGLE CLIP LOCATED AT BS 400 AND STR 26L FWD CARGO COMPARTMENT IAW SRMSDR R61A2021110300864Doubler · corrodedDURING HEAVY CHECK MAINTENANCE FOUND AFT FUSELAGE III FLOOR STRUCTURE RH IB DOUBLER CORRODED BETWEEN FR85 AND 86, RBL 11. AFT FUSELAGE III FLOOR STRUCTURE RH IB DOUBLER BETWEEN FR85 AND 86, RBL 11 REPLACED WITH NEW PART IAW EMB 170 SRM 51-41-01 AND 51-43-03.SDR SWAA2021110231245Seat Track · elongatedFLIGHT DECK CAPT. SEAT TRACK AFT OUTBOARD; LOCK PIN HOLES ENLARGED. SEAT TRACK AFT INBOARD; LOCK PIN HOLES ENLARGED AND TOP SURFACE GROOVED. ; / [01] REMOVED AND REPLACED FLIGHT DECK CAPT'S AFT I/B SEAT TRACK IAW AMM 25-11-11-400-801.; [02] VERIFIED CORRECTIVESDR SWAA2021110231247Seat Track · elongatedFLIGHT DECK; F/O SEAT TRACK AFT OUTBOARD LOCK PIN HOLES ENLARGED. F/O SEAT TRACK AFT INBOARD LOCK PIN HOLES ENLARGED AND TOP SURFACE GROOVED. ; / [01] REMOVED AND REPLACED FLIGHT DECK FO'S AFT I/B AND O/B SEAT TRACKS IAW AMM 25-11-11-400-801.; [02] VERIFIED COSDR R61A2021110200849Doubler · corrodedWHILE AC WAS IN FOR HVY CK FOUND CENTER FUSELAGE 1 CABIN FLOOR STRUCTURE FR 19- FR20 LBL 24 FLOOR DOUBLER CORRODED. MX REPLACED DOUBLER PN 170-07311-001 IAW SRM 51-41-02, 51-43-04. SEE AAR NRC# 4500976-2000-0139 FOR WORK PERFORMED. AC REMAINS IN YQG FOR COMPLESDR R61A2021110200848Plate · corrodedWHILE AC WAS IN FOR HVY CK FOUND AFT FUSELAGE 3 FLOOR STRUCTURE RH OB SILL PLATE CORRODED AT FR 89 RBL 39. MX REPLACED SILL PLATE PN 170-86181-005 IAW SRM 51-43-03, SEE AAR NRC# 4500976-1000-0100 FOR WORK PERFORMED AC REMAINS IN YQG FOR COMPLETION.SDR R61A2021110200845Beam · corrodedWHILE AC WAS IN FOR HVY CK AFT FUSELAGE 3 FLOOR STRUCTURE RH IB FLOOR BEAM AT FR 87 RBL 11 CORRODED. MX REPLACED FLOOR BEAM PN 170-65669-004 IAW SRM 51-41-01, 51-43-04 SEE AAR NRC# 4500976-1000-0102 FOR WORK PERFORMED.AC REMAINS IN YQG FOR COMPLETION.SDR REXA2021102100882Post · crackedON AC N8908, DURING 6K INSPECTION FOUND CRACK ON VERTICAL POST LOWER FLANGE STARTING AT LOWEST RIVET EXTENDING UPWARD TO THE FLANGE BEND RADIUS. A/C LOCATION IS @ F.S. 409+128 LBL 27.0.SDR SWAA2021101930565Support · crackedRIGHT WHEEL WELL WHEEL WELL RING SUPPORT ASSEMBLY HAS 4 CRACKS EXTENDING FROM A FASTENER HOLE 2 CRACKS EXTEND FORWARD AND MEASURE .5500 F AN INCH. 2 CRACKS EXTEND AFT AND MEASURE .300 OF AN INCHCOMPLIED WITH EA 21-153-02505 STOP DRILLED CRACKS; DO A GVI INSP OSDR SWAA2021101931471Floor Support · crackedCENTER FLOOR SUPPORT AT STA. 540 CRACKED / REMOVED & REPLACED CENTER FLOOR SUPPORT @ STA 540 IAW SRM 51-40-02 (BREAK ASSY PANEL)SDR QXEA2021101800474None · corrodedSEAT RAIL 9 FROM FSX668-X783Y-9.250 IS CORRODED. DAMAGE ON SEAT RAIL 9 REPAIRED IAW RD 8/4-53-10380. NDT DONE SKYSERVICE NO CRACKS FOUND. SEAT RAIL REPROTECTED IAW RD 8/4-53-10380.SDR SWAA2021101830536Support · corrodedSUPPLEMENTAL INFORMATION: AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT IS CORRODED AT WL 153; STA727D+18; RBL 22; STA727E+1.5; RBL 20; STA727E+2; RBL 22; STA727E+5; RBL 20; STA727E+6; RBL 22; STA727E+8; RBL 22; STA727E+10; RBL 22; STA727E+14 RBL 22; STA727E+18 RBL SDR SWAA2021101830538Support · corrodedSUPPLEMENTAL INFORMATION: AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT IS CORRODED AT WL 153; STA767+2; LBL 21; STA767+7; LBL 20 TO 22; STA767+10; LBL 22; STA767+13; LBL 20; STA767+14; LBL22; STA767+18; LBL 22; STA767+18.5; LBL20; STA787+6 LBL 22. / REMOVED CORROSISDR SWAA2021101829847Panel · crackedSUPPLEMENTAL INFORMATION: 193D PNL TRAILING EDGE HAS 7 FASTENER HOLES THAT ARE CRACKED DIMPLED AND ELONGATED ; / [01] ACCOMPLISH EA 21-153-03040 ASSIGNED AS A SUBTASK.; [02] C/W EA 21-153-03040SDR SWAA2021112330270Track · crackedCRACK TRACK RBBL 13.84 LOCATED BETWEEN BS 767 TO BS 727E AT AFT CARGO COMPARTMENT ; 2021-460776 / [01] TOOL USED: ET EQUIPMENT P/N: NORTEC 600D; S/N: 200048001; CAL DUE DATE: 24-FEB-22; [02] TOOL USED: ET EQUIPMENT P/N: NORTEC 600D; S/N: 200048001; CAL DUE DATSDR SWAA2021112330265None · crackedCRACK ANGLE - SUPPORT AFT LOCATED BS 907 TO BS 927 BTW S-27R TO S-25R AFT CARGO COMPARTMENT ; 2021-460773 / [01] REPLACED ANGLE- SUPPORT AFT (STIFFENER) LOCATED BS 907 TO BS 927 BTW S-27R TO S-25R IAW B737-700 SRM 51-10-02 AND DWG 147A7221 REV ?D; [02] REPLACESDR SWAA2021112330269None · crackedCRACK ANGLE - SUPPORT FWD LOCATED BS 907 TO BS 927 BTW S-27R TO S-25R AFT CARGO COMPARTMENT ; 2021-460774 / [01] REPLACED ANGLE-SUPPORT FWD(STIFFENER) AND FASTENERS LOCATED BS 907 TO BS 927 BTW S-27R TO S-25R AFT CARGO COMPARTMENT IAW SRM B737-700 51-10-02 ANDSDR SWAA2021112330271None · crackedCRACK WEB - INTERCOSTAL LOCATED BS 927 TO BS 947 AND RBL 21 AFT CARGO COMPARTMENT ; 2021-460767 / [01] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE: 21-JAN-22; [02] REPLACED INTERCOSTAL LOCATED BS 927 TO BS 947 AND RBL 21 AFT CARSDR SWAA2021112330267None · corrodedCORROSION SUPPORT ZEE LOCATED BS 727 TO BS 847 AND LBL 21 WL 156 AFT CARGO COMPARTMENT ; 2021-460770 / [01] REPAIRED SUPPORT ZEE BTW BS 727 TO BS 807 AND LBL 21 WL 156 AFT CARGO COMPARTMENT IAW SRM B737-700 53-00-53-2R-6 REPAIR 6 AND DWG 146A7502 REV. ?A?. ANDSDR SWAA2021112330266None · corrodedCORROSION WEB - INTERCOSTAL LOCATED BS 767 TO BS 787 AND RBL 21 WL 156 AFT CARGO COMPARTMENT ; 2021-460799 / [01] REPLACED WEB - INTERCOSTAL LOCATED BS 767 TO BS 787 AND RBL 21 WL 156 AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 PARAGRAPH 9; SRM 51-40-02 ANSDR SWAA2021112330268None · crackedCRACK ANGLE - SUPPORT LOCATED BS 947.5 AND LBL 8.10 AFT CARGO COMPARTMENT ; 2021-460800 / [01] REPLACED NEW ANGLE LOC BS 947.5 AT LBL 8.10 I.A.W SRM B737-700 51-40-02; 51-10-02 ITEM 9 AND DWG 149A8103 SHEET 6 REV-; [02] REPLACED NEW ANGLE LOC BS 947.5 AT LBL 8SDR SWAA2021112330272None · corrodedCORROSION SUPPORT ZEE LOCATED BS 727 TO BS 767 AND RBL 21 WL 156 AFT CARGO COMPARTMENT ; 2021-460801 / [01] REPLACED SUPPORT ZEE LOCATED BS 727 TO BS 767 AND RBL 21 WL 156 AFT CARGO COMPARTMENT IAW SRM B737-700 51-10-02 AND DRAWING 146A7500 REV:-; SEE INDIVIDUSDR SWAA2021111930412Support Bracket · corrodedCORROSION BS 259 - BS 270 VIEWING WINDOW SUPPORT IS CORRODED ON THE UPPER SURFACE. ; / [01] REMOVED CORROSION ON UPPER SURFACE VIEW WINDOW SUPPORT CHANNEL AT B.S 260-270 BL 0; MATERIAL REMOVED 6'L X 3'W PER SRM 53-10-51-1A-1; [02] VERIFIED CORRECTIVE ACTION STSDR REXA2021111600973Seat Track · corrodedLH SIDE SEAT RAIL FS 744-752 HAS CORROSION ON MULTIPLE SPOTS. - REMOVED AND REPLACED LH SIDE SEAT RAIL FS 744 - FS 752 IAW CRJ 900 AMM 53-00-49-000/400-801-A07. WVAC EMP STAMP #776 MTCSDR SWAA2021111130416None · corrodedBS 270 UPPER CHORD LBL-11 TO RBL-11 IS CORRODED. ; / [01] REMOVED CORROSION ON UPPER CHORD B.S 270 LBL 11-RBL 11 WL 207.5;MATERIAL REMOVED 19'L X .900'W.PER SRM 53-10-51-1A-1FIG 104.; [02] VERIFIED CORRECTIVE ACTION STATEMENT 1; [03] UT INSPECTED BLENDED AREASSDR SWAA2021111130414Floor Support · corrodedFLOOR SUPPORT AT BS 259- BS 270 LBL-11 UPPER SURFACE IS CORRODED. ; / [01] REMOVED CORROSION ON FLOOR SUPPORT UPPER SURFACE AT B.S 260-270;MATERIAL REMOVED 7'L X.900'W PER SRM 53-10-51-1A-1 FIG 104; [02] VERIFIED CORRECTIVE ACTION STATEMENT 1; [03] UT INSPECTESDR SWAA2021111130415None · corrodedBS 259 UPPER CHORD LBL-11 TO RBL-11 UPPER SURFACE IS CORRODED. ; / [01] REMOVED CORROSION ON UPPER CHORD B.S 259 LBL 11-RBL 11 WL 207.5;MATERIAL REMOVED 18'L X .800'W.PER SRM 53-10-51-1A-1FIG 103.; [02] VERIFIED CORRECTIVE ACTION STATEMENT 1; [03] UT INSPECTEDSDR SWAA2021110929830Scuff Plate · crackedFWD CARGO FWD SCUFF PLATE CRACKED ; / [01] RECEIVED WELDED SCUFF PLATE ON TAG #397070; ISSUE TAG #HZ896; P.O.#1734696. WILL BE INSTALLED ON CARD 3 # TTG8Q004G7HY; [02] VERIFIED STEP 1SDR ASAA2021101436511Cargo Track · corrodedFWD CARGO TRACK TIE DOWN LUG AT STA 500L HAS 2 EA. CORRODED NUT PLATES O/B SIDE OF LUG. GROUNDED - YES. SURFACE BLENDED R/H CARGO TRACK TIE DOWN AT STA. 500L, FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED DAMAGED TRACK WITH NEW STA 500C TO 500L AND RESTORED SDR R61A2021110200854Doubler · corrodedWHILE AC WAS IN FOR HVY CK FOUND FWD FUSELAGE FLOOR STRUCTURE CORROSION FOUND ON EXISTING REPAIR AT FLOOR BEAM 15 RH SIDE. MX REPLACED REPAIR PN 7075-T6 0.063 IAW SRM 51-43-04. SEE AAR NRC# 4500976-1000-0055 FOR WORK PERFORMED. AC REMAINS IN YQG FOR COMPLETIONSDR R61A2021110200853Doubler · corrodedWHILE AC WAS IN FOR HVY CK FOUND FWD FUSELAGE FLOOR STRUCTURE CORROSION FOUND ON RH DOUBLER OB BETWEEN FR 12-14. MX REPLACED PN 170-05663-003 IAW SRM 51-41-02, 51-43-04 SEE AAR NRC# 4500976-1000-0054 FOR WORK PERFORMED. AC REMAINS IN YQG FOR COMPLETION.SDR R61A2021110200852Support · corrodedWHILE AC WAS IN FOR HVY CK FOUND AFT FUSELAGE 3 FLOOR STRUCTURE FLOOR PANEL SUPPORT CORRODED AT FR 85 LBL 28. MX REPLACED SUPPORT PN 170-66796-001 IAW SRM 51-41-01. SEE AAR NRC# 4500976-1000-0081 FOR WORK PERFORMED.SDR R61A2021110200851Doubler · corrodedWHILE AC WAS IN FOR HVY CH FOUND FWD FUSELAGE 3 FLOOR STRUCTURE DOUBLER CORRODED ON FR 90 RBL 23. MX REPLACED DOUBLER PN 170-60259-001 IAW SRM 51-41-02 SEE AAR NRC# 4500976-1000-0079 FOR WORK PERFORMED. AC REMAINS IN YQG FOR COMPLETION.SDR R61A2021110200850Seat Track · corrodedWHILE AC WAS IN FOR HVY CK FOUND FWD FUSELAGE FLOOR STRUCTURE CORROSION FOUND ON INBD RH SEAT TRACK BTWN FR 12-18. MX REPLACED SEAT TRACK PN 170-03263-001 IAW SRM 51-41-01, 51-41-02, 51-43-03, 51-43-04. SEE AAR NRC# 4500976-1000-0056 FOR WORK PERFORMED. AC REMSDR R61A2021110300865Shear Panel · corrodedDURING HEAVY CHECK MAINTENANCE FOUND AFT FUSELAGE III FLOOR STRUCTURE LH SHEAR PANEL BETWEEN FR87 AND FR88, LBL 11 TO LBL 40 CORRODED. AFT FUSELAGE III FLOOR STRUCTURE LH SHEAR PANEL BETWEEN FR87 AND FR88, LBL 11 TO LBL 40REMOVED AND REPLACED IAW EMB 170 SRM 5
Back to JASC 5320