What was found
FS 280 CROSSBEAM LOWER SPLICE ANGLE CORRODED AND BLOWN UP HOLES. - FOUND SPLICE ANGLE TO BE OUT OF LIMITS PER CRJ 900 SRM 53-00-00-101-001-A01, LOCATED, DRILLED & INSTALLED & PAINTED SERVIEABLE SPLICE ANGLE IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, & 51-25-00-001-001-A01. WVAC EMP STAMP # 774 MTC