JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021062876371Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS500B FWD SIDE LBL25 WL156. ; / [01] INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS 500B LBL 25 WL 156 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE FOUND IN SRM; PART WILL BE REPAIRED BY REPLACEMENT PER SDR SWAA2021062876370Attach Angle · crackedCRACKED INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS500C FWD SIDE LBL25 WL156. ; / [01] INTERCOSTAL ATTACH ANGLE AT FWD CARGO BAY BS 500C LBL 25 WL 156 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE FOUND IN SRM; PART WILL BE REPAIRED BY REPLACEMENT PER SDR SWAA2021062876369Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500B+9 LBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM 53-30-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BSSDR SWAA2021062876368Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+15 LBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM 53-30-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BSDR SWAA2021062876367Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+10 LBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM 53-30-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BSDR SWAA2021062876366Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+18 RBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM53-00-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT FWDSDR SWAA2021062876365Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+15 RBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM53-00-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT FWDSDR SWAA2021062876364Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+3 RBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM53-00-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT FWD SDR SWAA2021062876363Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+2 RBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM53-00-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT FWD SDR SWAA2021062876340Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+7 LBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM 53-00-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BSSDR SWAA2021062876339Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+3 LBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM 53-30-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-1 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BSSDR SWAA2021062876338Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500B+6 RBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM53-00-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT FWD SDR SWAA2021062876337Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500B+2 RBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM53-00-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT FWD SDR SWAA2021062876335Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+10 RBL22 WL157. ; / [01] VERIFIED APPLICABILITY FOR IDENTIFICATION SRM 53-30-53-01-2 AND ALLOWED DAMAGED SRM 53-00-53-1A-2; REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS SDR SWAA2021062876334Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500A+6 RBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM53-00-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT FWD SDR HNAA2021062400282Floor Support · corrodedLH OUTBD #7 FLOOR SILL IS PITTED. REMOVED AND REPLACED LH OUTBD #7 FLOOR SILL IAW EMB 145 SRM 51-20-03 & SRM 51-40-02.SDR HNAA2021062400279Floor Support · corrodedLH OUTBD FLOOR SILL #6 IS PITTED. REMOVED AND REPLACED LH OUTBD # 6 FLOOR SILL IAW EMB 145 SRM 51-20-03 & SRM 51-40-02.SDR HNAA2021062400278Floor Support · corrodedRH OUTBD FLOOR SILL #4 IS PITTED. REMOVED AND REPLACED RH OUTBD FLOOR SILL #4 IAW EMB 145 SRM 51-40-02.SDR HNAA2021062400277Floor Support · corrodedRH OUTBD #3 FLOOR SILL IS PITTED. REMOVED AND REPLACED RH OUTBD #3 FLOOR SILL IAW EMB 145 SRM 51-20-03,51-40-02. RESTORED TO ORIGINAL FINISH IAW EMB 145 CPM 51-21-06,P-IEDMONT BULLETIN #51-02.SDR HNAA2021062400275Floor Support · corrodedRH OUTBD #2 FLOOR SILL IS PITTED. REMOVED AND REPLACED RH OUT BOARD #2 FLOOR SILL IAW EMB 145 SRM 51-40-02.SDR HNAA2021062400274Floor Support · corrodedRH #4 CARGO FLOOR SILL CORRODED. REMOVED AND REPLACED RH #4 CARGO FLOOR SILL IAW EMB--145 SRM 51-40-02.SDR HNAA2021062400272Floor Support · corrodedRH OUTBD FLOOR SILL #5 IS PITTED. REMOVED AND REPLACED RH OUT-BD FLOOR SILL #5 IAW EMB 145 SRM 51-40-02.SDR HNAA2021062400271Floor Support · corrodedLH OUTBD FLOOR SILL #4 IS PITTED. REMOVED AND REPLACED LH OUTBD FLOOR SILL #4 IAWEMB 145 SRM 51-40-02 & SRM 51-20-03.SDR SWIA202158999Door Sill · corroded* PAX DOOR LOWER SILL MID CAP ANGLE CORRODED. (C-CHECK RO: 6/20/21) / REMOVED AND REPLACED CORRODED LOWER MID CAP ANGLE WITH NEW REPLACEMENT MID CAP ANGLE (P/N SH670-31825-9S) USING NEW HARDWARE, REF CRJ700 SRM 51-41-02-001-001 A01. SEE CONTINUATION CARD FSDR SWIA2021062358961Plate · corroded* PAX DOOR LOWER SILL ANGLE KICK PLATE CORRODED IN MULTIPLE SPOTS (MARKED). P/N SH670-31875. (C-CHECK RO: 6/20/21) / REMOVED AND REPLACED CORRODED PAX DOOR LOWER SILL ANGLE WITH NEW REPLACEMENT LOWER SILL ANGLE KICKPLATE (P/N SH670-31875-5) USING ALL NEW HASDR R61A2021061500494Doubler · corrodedWHILE AC WAS IN FOR HVY CK FOUND CF3 FLOOR STRUCTURE CORROSION FOUND ON UPPER SHEET DOUBLER LH AFT INBD SEAT TRACK BTWN FR 85-86. REPLACED DOUBLER PN 170-86101-001 IAW SRM 51-41-01, 51-43-03.SDR R61A2021061500493Support · corrodedWHILE AC WAS IN FOR HVY CK FOUND CF3 FLOOR STRUCTURE CORROSION FOUND ON RH PANEL SUPPORT BTWN FR88-90. REPLACED RH PANEL SUPPORT PN 170-86181-005 IAW SRM 51-41-01, 51-43-03. SEE AAR NRC#4500913.2000-0125 FOR WORK PERFORMED. AC WAS RTS'ED.SDR R61A2021061500492Gusset · corrodedWHILE AC WAS IN FOR HVY CK FOUND CF3 FLOOR STRUCTURE CORROSION FOUND ON RH GUSSET PLATE AT FR 90. REPLACED GUSSET PLATE PN 170-60259-001 IAW SRM 51-41-02. SEE AAR NRC# 4500913-2000-0124 FOR WORK PERFORMED. AC WAS RTS'ED.SDR R61A2021061300485Floor Support · corrodedCFIII, FLOOR STRUCTURE, FORROSION FOUND ON LH PANEL SUPPORT AT FR 84. REPLACED L/H O/B FLOOR PANEL SUPPORT AT FR 84 WITH NEW. P/N 170-92907-001 IAW SRM 51-41-01 AND SRM 51-41-02SDR AALA202106119008Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF WEB Z-ANGLE AT STA 992 AT RBL 32, MEASURING L=1.0 IN, W=1.0 IN, D=0.05 IN. REPLACED Z-ANGLE WITH NEW IAW AARD 51-00-05-1 AND DRAWING 147A5700.SDR AALA202106119024Web · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND CORRODED WEB AT STA 992 AND LBL 32. INSTALLED DOUBLE REPAIR REF EA 328189.SDR AALA202106119023Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: INTERCOSTAL CRACKED BETWEEN STA 278-294 AT BL-0. INSTALLED UPDATED INTERCOSTAL REF AARD 51-00-05-1.SDR AALA202106119022Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: INTERCOSTAL CRACKED BETWEEN STA 312-328 AT RBL 31. INSTALLED MODIFIED INTERCOSTAL IAW AARD 51-00-05-1.SDR REXA2021052800369Floor Support · corrodedL/H FLOOR ANGLE AT PAX DOOR ENTRANCE WL 72.50 CORRODED AT FS 320.00 TO FS 340.00. REMOVED AND REPLACED LH FLOOR ANGLE AT PAX DOOR ENTRANCE WL 72.50 AT FL 320 TO FS 340 PART #SH670-31875-7S IAW CRJ 900 SRM 51-42-006-001-001-A01.SDR SWAA2021052876214Panel · damagedPANEL 194E AFT EDGE BAND HAS 2 EACH ELONGATED FASTENER HOLES. ; 1ST FASTENER HOLE FROM L/H O/B EDGE IS 0.440 INCH DIAMETER.5TH FASTENER HOLE FROM L/H O/B EDGE IS 0.360 INCH DIAMETER. / REMOVED AND REPLACED PANEL 194E IAW AMM 53-51-21.SDR SWAA2021052876193Panel · pulledPANEL 194E HAS SEVERAL HOLES WHERE THE SCREW HAS PULLED THROUGH THE COUNTER SINKS. ; / INSTALLED PNL PER AMM 53-51-21SDR SWAA2021052876192Panel · damagedPANEL 193D HAS SEVERAL OBLONG AND OVERSIZED HOLES. ; / INSTALLED PNL PER AMM 53-51-21SDR IPXA2021052769906Support Bracket · crackedINSPECTION TYPE:A300MCD FR38 TO FR38.1 SUPPORT AT Y2400 CRACKEDREMOVED AND REPLACED IAW SRM 51-40-21.SDR DALA2021052502895Floor Support · corrodedSHIP 685 CORROSION FLOOR STRINGER RBL 7.55 BTW STA 640 TO STA 660 AT FWD CARGO COMPARTMENT. IN ORDER TO PERFORM NRC 298. CORRECTIVE ACTION: OF NRC 00903: SECTION OF FLOOR STRINGER WAS REPLACED PER B757-200 SRM. (1818719SDR DALA2021052502894Floor Support · corrodedSHIP 685 CORROSION ON FLOOR STRINGER STA 625, LBL 7.55 AT FWD CARGO COMPARTMENT. (C1) (IN REFERENCE NRC 00211). CORRECTIVE ACTION: SUMMARY OF NRC 00954: FLOOR STRINGER ON STA 625, LBL 7.55 WAS REPAIRED PER B757-200 SRM. (1818467)SDR CALA2021052400732Buttstrap · wornBUTT STRAP AT STA.887 BETWEEN S-27L AND S-27R IS WORN THROUGH. REMOVED SHEAR TIE AT STA887 STR27L TO 26L REF SRM 51-40-02 REMOVED SHEAR TIE STA887 FROM STR27R TO 26R REF SRM 51-40-02 REMOVED INTERCOSTAL FROM STA887 TO 867 BETWEEN STR27L AND STR26L REF SRM 51-4SDR SWAA2021062876149Gusset · crackedCRACKED GUSSET IN FCB; BS 500D; S-19R (MARKED) ; / [01] REMOVED GUSSET AT BS 500D STR19R IAW SRM 51-40-02; [02] LOCATED AND DRILLED NEW GUSSET AT BS 500D STR 19R; PN#143A9483-5 IAW SRM 51-40-02 AND IAW DWG#143A9481. OK TO INSTALL; [03] OK TO INSTALL.; [04] INSSDR SWAA2021062876148Gusset · crackedCRACKED GUSSET IN FCB; BS 500D; S-19L (MARKED) ; / [01] REMOVED GUSSET AT BS 500D STR19L IAW SRM 51-40-02; [02] LOCATED AND DRILLED NEW GUSSET AT BS 500D STR19L; PN#143A9483-6 IAW SRM 51-40-02 AND IAW DWG#143A9481. OK TO INSTALL; [03] CORRECTION: LOCATED AND DSDR IPXA2021061470549Stiffener · crackedINSPECTION TYPE:SEGTAIL COMPARTMENT BILGE BETWEEN FR 86 AND 89 L/H SIDE, WEB STIFFENER DEFORMED AND CRACKEDFABRICATED, LOCATED, DRILLED NEW WEB STIFFENER AND INSTALLED NEW PART IAW SRM 51-40-44 AND 51-40-21SDR IPXA2021061470509Support · damagedINSPECTION TYPE:2CFWD. CARGO CEILING SUPPORT HAS DAMAGED FASTENER HOLES BETWEEN STA. 909 TO 1009 AT X= -14.REPAIRED DAMAGED CEILING SUPPORT BETWEEN STA 909 TO 1009 AT X= -14 IAW VT-SAA EA 011 5320-01-A9158 REV. I/R AND UPS EO MD11-5320-80668-A. (MAJOR) REF 810SDR SWAA2021061476238Baffle · damagedFWD CARGO BAY BAFFLE DAMAGED AT FASTENER HOLE BS 500 - BS 500A LBL 22 WL 157 ; / VERIFIED LOCATED HOLES AND DRILLED PER SRM 51-40-05. OK TO INSTALL; INSTALLED FCB BAFFLE BS 500- BS 500A; LBL 22; WL 157 IAW BOEING DWG 143A7505; BOEING DWG 143A1212 AND SRM 51-40SDR HNAA2021061400245Gusset · corrodedCORROSION ON DIAMOND GUSSET AT FRAME 28 ... REMOVED AND INSTALLED SERVICEABLE DIAMOND GUSSET AT FRAME 28 IAW EMB 145 SRM 51-40-02 AND EMB 145 SRM 51-20-03.SDR HNAA2021061400239Floor Support · corrodedCORROSION ON PASSENGER DOOR ENTRY FWD FLOOR BOARD SUPPORT ... RAR PAX DOOR ENTRY FWD FLOOR SUPPORT IAW EMB-145 SRM 51-40-02.SDR HNAA2021061400238Floor Support · corrodedCORROSION ON CROSS FLOOR BOARD SUPPORT AT PASSENGER DOOR ENTRY AT FRAME 18 ... REMOVED AND INSTALLED SERVICEABLE CROSSBEAM AT FR 18 IAW EMB 145 SRM 51-40-02.SDR YENA2021052700337Floor Support · corrodedDURING HEAVY MAINTENANCE, FUSELAGE / CENTER FUSELAGE III / FLOOR STRUCTURE BEAMS AT FR87-88 AND Y-273 / CORROSION - PERMANENT REPAIR; THIS PERMANENT REPAIR HAS BEEN APPROVED VIA REF /2/ ETD (WITH ATTACHED ANAC FORM) AND IS CLASSIFIED AS MAJOR.
Back to JASC 5320