What was found
***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500B+9 LBL22 WL157. ; / [01] VERIFIED APPLICABILITY ON SRM 53-30-53-OI-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BS 500B + 9'' LBL22 WL157 P/N 143A7501-183 IN AREA OF 3'X2'X0.020'DEEP; ORIGINAL MATERIAL THICKNESS 0.040'' FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2 PAR. 4.A. (2) FIG. 103 DETAIL A. <BR>TOOL USED: DEPTH GAGE; ID:ATS 2473; S/N:UNKNOWN.; [03] VERIFIED REMOVAL OF CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BS 500B + 9'' LBL22 WL157 P/N 143A7501-183 IN AREA OF 3'X2'X0.020'DEEP; ORIGINAL MATERIAL THICKNESS 0.040'' FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2 PAR. 4.A. (2) FIG. 103 DETAIL A. <BR>TOOL USED: DEPTH GAGE; ID:ATS 2473; S/N:UNKNOWN.; [04] THIS JOB CARD WILL BE ACCOMPLISHED WITH CUSTOMER CARD # TTG8Q0054DRO.; [05] CORRECTED CARD# TO TTG8Q0054DR0; [06] VERIFIED PART WILL BE REPLACED ON TTG8Q0054DR0