JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20210310048Support · crackedCENTER FLOOR BEAM (L) SUPPORT BRACKET CRACKED AFTER RM 21 STE 21R. REMOVED AND INSTALLED SUPPORT BRACKET.SDR MASA20210408159Floor Support · corrodedCORROSION ON FLOOR BEAM 9RBL IN STA. FS= 1000 TO FS= 1069 AT AFT BAGGAGE BAY. CORRECTIVE ACTION: FLOOR BEAM 9RBL IN STA. FS= 1000 TO FS= 1069 AT AFT BAGGAGE BAY WAS REPAIRED PER E/A 72-2021-068 REV. IRSDR AALA202104089001Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: FOUND L=1.1375 CRACK AT SHEAR PLATE LOCATED BETWEEN FR 69 TO FR 70 AT STR 23L. REPLACED SHEAR PLATE REF A321 SRM 54-42-11-801 AND DWG # D53474180.SDR SWIA202157453Bracket · corrodedBRACKET ASSY FOUND CORRODED AT FS 349.00 AND INTERCOSTAL BELOW GALLEY SERVICE DOOR BETWEEN STR19R AND STR20R (C-CHECK RO 4/4/2021) INSTALLED NEW REPLACEMENT BRACKET, P/N: SH670-41506-5 REF CRJ700 SRM 51-42-06-001-001-A01. / INTERCOSTAL REPLACED ON JOB:SDR SWIA202157427Angle · corrodedANGLE AT FOUND CORRODED AT FS 349.00 AND INTERCOSTAL BELOW GALLEY SERVICE DOOR STRUCTURE BETWEEN STR20R AND STR19R (C-CHECK RO 4/4/2021) REPLACED ANGLE AT FS349 BETWEEN STR20R-19R WITH NEW ANGLE REF CRJ-700 SRM 51-42-06-001-001-A01 AND DWG SH670-31950 RSDR SWIA202157426Angle · corrodedANGLE FOUND CORRODED AT FS 319.00 AND INTERCOSTAL BELOW GALLEY SERVICE DOOR BETWEEN STR20R AND STR19R (C-CHECK RO 4/4/2021) REPLACED ANGLE AT FS319 AND STGR20R INTERCOSTAL WITH NEW ANGLE REF CRJ-700 SRM 51-42-06-001-001-A01 AND DWG SH670-31950 REV Y. COMPSDR MASA20210405150Floor Support · corrodedCORROSION ON FLOOR BEAM 27LBL IN STA. FS=1000 TO FS=1047 AT AFT BAGGAGE BAY|FLOOR BEAM 27LBL IN STA. FS=1000 TO FS=1047 AT AFT BAGGAGE BAY WAS REPAIRED PER CRJ900 SRM 53-00-41-201-001-A03SDR MASA20210405131Floor Support · corrodedDUE TO EXCESSIVE CORROSION FLOOR BEAM 9 LBL IN STA FS=977 TO FS=1053 AT AFT BAGGAGE BAY WAS REPAIRED PER CRJ900 SRM 53-00-41-201-001-A03 PAR 5.SDR SWAA2021040555961Support · corroded***CORROSION*** SIDEWALL TO BULKHEAD SUPPORT BS 947 RBL 21 WL 156 / REMOVED DAMAGED SIDEWALL TO BKD AND INSTALLED NEW SIDEWALL TO BKD SUPPORT BS 947 RBL 21-45 WL 156 IAW SRM 51-40-02-0G-0 & DWG 149A8110; 147A7500SDR SWAA2021040556630Support Angle · crackedACB BULKHEAD SUPPORT ANGLE BS 727+4' RBL 4 WL 162 IS CRACKED REMOVED AND REPLACED ACB BULKHEAD SUPPORT ANGLE BS 727+4; WL 162; RBL 4 IAW SRM 5140020G0; DWG# 144A2600SDR SWAA2021040556640Intercostal · crackedFORWARD CARGO BAY CRACKED INTERCOSTAL BS400 TO BS420 STR26L WL158 / REPLACED FCB INTERCOSTAL BS 400 TO BS 420 STR 26L WL 158 PO # 764707 PER DWG 143A7505 AND SRM 51-40-02-0G-0SDR SWAA2021040556641Intercostal · crackedFORWARD CARGO BAY CRACKED INTERCOSTAL BS500 TO BS500A STR26L WL158 / REPLACED FCB INTERCOSTAL BS 500 TO BS 500A STR 26L WL 158 PO # 812273/6 PER DWG 143A7505 AND SRM 51-40-02-0G-0SDR SWAA2021040556642Intercostal · crackedFORWARD CARGO BAY CRACKED INTERCOSTAL BS500C TO BS500D STR26L WL158 / REPLACED FCB INTERCOSTAL BS 500C TO 500D STR 26L WL 158 PER SRM 51-40-02-0G-0 AND DWG 143A7505SDR SWAA2021040554776Intercostal · corroded***CORROSION*** ACB INTERCOSTAL BS 747-767 RBL 22 WL 156 / CORROSION ON INTERCOSTAL WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES PER: SRM 53-00-04-1A-1. INTERCOSTAL IS A PART OF THE 146A7502-51 ASSY AND WAS REPLACED ON NRC U287962SDR SWAA2021040554778Intercostal · corroded***CORROSION*** ACB INTERCOSTAL BS 767787 RBL 22 W L 156 CORROSION DAMAGE EVALUATION PN 146A812320 ACB INTERCOSTAL ASSY BS767787; RBL 22; WL 156; WAS FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO HOLES PER SRM 530004. REMOVED AND INSTALLED NEW ACB INTERCOSTAL SDR SWAA2021040556633Intercostal · crackedACB CRACKED INTERCOSTAL BS 927-947 RBL 21 WL 156 / REMOVED DAMAGED INTERCOSTAL AND INSTALLED NEW INTERCOSTAL AT BS 927-947 RBL 21 WL 156 IAW SRM 51-40-02-0G-0 AND DWGSDR SWAA2021040556634Angle · crackedACB CRACKED ANGLE BS 947 LBL 10 WL 156 / REMOVED DAMAGED ANGLE AND INSTALLED NEW ANGLE AT BS 947 LBL 10 WL 156 IAW SRM 51-40-02-0G-0 AND IPC 53-42-51-03SDR SWAA2021040554801Angle · crackedFORWARD CARGO BAY CRACKED CLIP AFT SIDE OF THE FRAME BS400 LBL21 WL158 / REPLACED FCB CLIP AFT SIDE OF THE FRAME BS 400 LBL 21 WL 158 PER SRM 51-10-02-0G-0 AND DWG 143A7505SDR SWAA2021040556631Angle · crackedACB CLIP CRACKED BS 827 RBL 19 WL 156 REPLACED ACB CLIP BS 827 RBL 19 WL 156 PO# 817763 PER SRM 5140020G0 AND DWG 146A8120SDR SWAA2021040554787Support Angle · corroded***CORROSION*** ACB SHIELD SUPPORT ANGLE BS 767-787 RBL 22 WL 156 / CORROSION DAMAGE EVALUATION ON ACB SHIELD SUPPORT ANGLE BS 767-787; RBL 22; WL 156 WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS GIVEN IN SRM. NEW ACB SHIELD SUPPORT ANGLE WILL BE REPLACED ASSDR SWAA2021040554799Shield · corroded***CORROSION*** FORWARD CARGO BAY SHIELD BS492 TO B500A RBL 23 WL156 / REMOVED AND REPLACED FCB SHIELD BS 492 TO BS 500A RBL 23 WL 156 I.A.W SRM 51-40-02-0G-0 AND DWG 143A0080 REV:-SDR SWAA2021040554773Support · corroded***CORROSION*** ACB FLOOR TO SIDEWALL SUPPORT BS 727+4' TO 767 RBL 21 WL 156 / CORROSION ON SUPPORT WAS FOUND TO BE OUT OF LIMITS DUE PRIXCIMITY TO FASTENER HOLES PER: SRM 53-00-53-1A-2. REMOVED AND REPLACED SUPPORT PER SRM 51-40-02 AND DRAWING 146A7500SDR SWAA2021040554777Shield · corroded***CORROSION*** ACB SHIELD BS 767-792 RBL 22 WL 156 / CORROSION DAMAGE EVALUATION ON ACB SHIELD P/N 146A8127-12 WAS FOUND TO BE OUT OF LIMITS. DUE TO NO LIMITS GIVEN IN SRM. REMOVED AND INSTALLED NEW ACB SHIELD BS 767-792; RBL 22; WL 156. PER DWG 146A0081. ANDSDR SWAA2021040554780Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' RBL 8 WL 156 / FOUND OUT OF LIMITS DUE TO NO SRM LIMITS. REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER SRM 51-40-02 (737-700) AS SHOWN IN 1-A53-4982 REV 3.SDR SWAA2021040554781Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' RBL 3 WL 156 / FOUND OUT OF LIMITS DUE TO NO LIMITS (SRM.) REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER 737-700 SRM 51-40-02 AS SHOWN IN 1-A53-4982 REV 3SDR SWAA2021040554782Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' LBL 3 WL 156 / FOUND OUT OF LIMITS DUE TO NO SRM LIMITS. REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER 737-700 SRM 51-40-02 AS SHOWN IN 1-A53-4982 REV 3.SDR SWAA2021040554783Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' LBL 8 WL 156 / FOUND OUT OF LIMITS DUE TO NO LIMITS. (SRM) REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER 737-700 SRM 51-40-02 AS SHOWN IN 1-A53-4982 REV 3SDR SWAA2021040554784Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' LBL 13 WL 156 / FOUND OUT OF LIMITS DUE TO NO SRM LIMITS REMOVED AND REPLACED DAMAGE REPAIR PARTS AS PER 737-700 SRM 51-40-02 AS SHOWN IN 1-A53-4982 REV 3.SDR SWAA2021040554798Shield · corrodedCORROSION FORWARD CARGO BAY SHIELD BS420TO BS 440 RBL 23 WL156 REMOVED AND REPLACED FORWARD CARGO BAY SHIELD ASSY BS 420 BS 440 RBL 23; WL 156 PER SRM 514005; 514002 AND DWG # 143A0080 REVSDR SWAA2021040554774Support · corroded***CORROSION*** ACB FLOOR TO SIDEWALL SUPPORT BS 727+4' TO 847 LBL 21 WL 156 / REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT AND INSTALLED NEW FLOOR TO SIDEWALL SUPPORT AT BS 847-927 LBL 21 WL 156 IAW SRM 51-40-02-0G & DWG 146A7500 AND 149A8102SDR SWAA2021040554785Floor Splice · corroded***CORROSION*** ACB EXISTING FLOOR SPLICE BS 767+5' LBL 17 WL 156 /SDR SWAA2021040554797Support · corroded***CORROSION*** FORWARD CARGO BAY L/H FLOOR TO SIDE WALL SUPPORT BS400 TO BS500D LBL 21 WL156 / REMOVED DAMAGED FLOOR TO SIDEWALL SUPPORT AND INSTALLED NEW FLOOR TO SIDEWALL SUPPORT AT BS 396 - 500D LBL 21 WL 156 IAW SRM 51-40-02-0G-0 & DWG 284A0603SDR SWAA2021040554802Angle · corroded***CORROSION*** ACB FLOOR TO SIDEWALL SUPPORT BS 88 7' TO 947 RBL 21 WL 156 / REMOVED FLOOR TO SIDEWALL SUPPORT DAMAGED AND INSTALLED NEW FLOOR TO SIDEWALL SUPPORT ANGLE AT BS 887-947 RBL 21 WL 156 IAW SRM 51-40-02-0G-0 AND DWG 147A7500SDR SWAA2021040158477Bracket · crackedCRACK BRACKET ON BS 947.5 AT LEVEL STR 25L AT AFT CARGO COMPARTMENT / REPLACED BRACKET (FITTING) ON BS 947.5 AT LEVEL STR 25L AT AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING 149A8103 REV.A PART USED P/N:149A8113U6SDR HNAA2021033000109Floor Support · corrodedREMOVED CORRODED RH #4 OUTBD FLOOR SILL POSITIONED DRILLED AND INSTALLED SERVICEABLE FLOOR SILL IAW EMB 145 SRM 51-20-03, 51-40-02. (SEE WIPS AND TASKS FOR DETAILS.)SDR HNAA2021033000106Support · corrodedTOILET WASTE VALVE SUPPORT IS CORRODED AT EXTERNAL SIDE...RAR WASTE VALVE SUPPORT IAW EMB 145 SRM 51-40-02 & EMB 145 SRM 51-40-09.SDR AALA202103309017Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON CARGO COMPARTMENT TRANSITION PANEL BETWEEN BS 500C AND 500I. REPLACED TRANSITION PANEL PER SRM 51-40-02.SDR AALA202103249014Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND CORROSION ON RIGHT TRANSITION SHIELD AT STA 767-787 AND STR 25R. REMOVED AND REPLACED TRANSITION SHIELD REF SRM 51-10-02.SDR R61A202103240067Gusset · corrodedWHILE AC WAS IN FOR HVY CK FOUND CENTER FUSELAGE 3 PAX FLOOR STRUCTURE CORROSION FOUND ON GUSSET @FR 89 RBL11. REPLACED GUSSET PLATE PN 170-60257-001 IAW SRM 51-41-02 SEE AAR NRC # 4500867-2000-0069. AC REMAINS IN YQG FOR COMPLETION.SDR AALA202103199026Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND CORRODED INTERCOSTAL AT STA 947 TO 967 AND LBL 24. REPLACED INTERCOSTAL REF SRM 51-00-05-1, SRM 51-40-02 AND BOEING DRAWING 147A5650.SDR DALA2021031101389Floor Support · damagedSHIP 3235 ELONGATED HOLE FLOOR BEAM +Y1227 LOCATED BTW FR66 TO FR68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (1751274)SDR DALA2021031101388Shear Plate · corrodedSHIP 3235 CORROSION SHEAR PLATE STR 23 L FR69 TO FR70 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED SHEAR PLATE PER A320 SRM 51-72-11-11. (1751271)SDR DALA2021031101387Shear Plate · corrodedSHIP 3235 CORROSION SHEAR PLATE STR 23 R AND FR69 TO FR70 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED SHEAR PLATE PER A320 SRM 51-72-11. (1751266)SDR DALA2021031101386Angle · corrodedSHIP 3235 CORROSION ANGLE WEB FLOOR STRUCTURE LOCATED FR69 TO FR70 AND STR23L AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED ANGLE PER A320 SRM 51-72-11. (1751263)SDR MASA20210310082Support · corrodedBACKUP SILL IN MAIN E&E BAY CORRODED AT STGR21L BETWEEN FS333-FS349|REPLACED SILL AT STGR21L BETWEEN FS333 AND FS349 IAW SRM 51-42-06 AND 51-42-21SDR CALA2021031000296Door Sill · corrodedCABIN R2 DOOR SILL PANEL FOUND CORROSION AT FR68 REF NON-ROUTINE NO.: 9428433 , SPEC NO: A3NB-53-3-6 187. CABIN R2 DOOR SILL PANEL AT FR68 REPAI RED AS PER SRM 53-41-14-300-001 REV 135.SDR CALA2021031000293Door Sill · corrodedR-2 AFT ENTRY DOOR CUTOUT FWD FR68 AREA UNDER PLANKING PLATE HAS AREAS OF CORROSION A3NB-53-3-6299. PER HAECO LCQ N/R 9296482/22 482. GENERATED BY MECH V311118. REMOVED AND REPLACED R-2 DOOR SILL @ FR 66-68 PER A319 SRM 51-42 -11-801 & D53480009002 REV A. REMOSDR SWIA202158788Intercostal · crackedINTERCOSTAL APPEARS TO BE CRACKED IN INBOARD UPPER RADIUS AT FS484, RBL36-RBL45, UNDER THE PRESSURE FLOOR. (C-CHECK RO 6/11/2021) REMOVED AND REPLACED CRACKED INTERCOSTAL WITH NEW INTERCOSTAL AT F.S, 484 RBL 36 TO RBL 45 IAW CRJ 200 SRM 51-40-11, 51-42SDR SWIA202158769Floor Support · corrodedFLOOR BEAM AT RBL9 HAS MULTIPLE SPOTS OF CORROSION FROM FS559.00+80 TO FS621.00 (C-CHECK RO 6/11/2021) REMOVED CORROSION FROM FLOOR BEAM CAP AT FS 559-112- FS 621 AT RBL 9 AND FOUND TO BE WITHIN LIMITS OF REO 601R-53-00-005 REV B DATED 2011-01-06. REMOSDR SWIA202158767Strap · corrodedUNDER FLOOR TENSION STRAP AT FS559 FROM RBL27 TO RBL45 IS CORRODED. (C-CHECK RO 6/11/2021) REMOVED AND REPLACED TENSION STRAP FROM RBL 27 TO RBL 45 IAW CRJ 200 SRM 51-42-06 AND DWG 601R31025. COMPLIED WITH SKYWEST TASK CARD AND ATTACHED COMPLETETD FORM
Back to JASC 5320