Service difficulty report · Door Sill · Airbus A319131

Difficulty date
March 10, 2021
Submitted
March 10, 2021
Operation
Air carrier
Aircraft
N846UA
Make and model
Airbus A319131
Aircraft serial
1600
Aircraft time
60,490 hours, 26,429 cycles
Part
Door Sill
Condition
Corroded
Location
R2 Door
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

R-2 AFT ENTRY DOOR CUTOUT FWD FR68 AREA UNDER PLANKING PLATE HAS AREAS OF CORROSION A3NB-53-3-6299. PER HAECO LCQ N/R 9296482/22 482. GENERATED BY MECH V311118. REMOVED AND REPLACED R-2 DOOR SILL @ FR 66-68 PER A319 SRM 51-42 -11-801 & D53480009002 REV A. REMOVED DOT CS900. BY MECH V061737 INSP N078570