JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021032252916Angle · corrodedAFT CARGO STA 727F + 9 RBL 23 TRANSITION ANGLE HAS LIGHT CORROSION MARKED / REMOVED CORROSION AT AFT CARGO R/H TRANSITION ANGLE BS 727F + 9 FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-2A-1. REMOVED AND REPLACED SECTION OF TRANSITION ANGLE 727F+9 THRU 767 R/H PERSDR SWAA2021032252919Angle · corrodedAFT CARGO STA 727H RBL 33 TRANSITION ANGLE HAS LIGHT CORROSION AROUND FASTENER MARKED / REMOVED CORROSION AT AFT CARGO R/H TRANSITION ANGLE FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-2A-1 REPAIR ACCOMPLISH ON NON ROUTINE D457396SDR SWAA2021032252922Track · corrodedAFT CARGO STA 727H + 13 RBL 23 TRANSITION ANGLE HAS LIGHT CORROSION MARKED / REMOVED CORROSION AT AFT CARGO R/H TRANSITION ANGLE BS 727H +13 FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-2A-1. REPAIR ACCOMPLISH ON NON ROUTINE D457396SDR SWAA2021032252923Angle · corrodedAFT CARGO STA 727H + 16 RBL 23 TRANSITION ANGLE HAS LIGHT CORROSION MARKED / REMOVED CORROSION AT AFT CARGO R/H TRANSITION ANGLE BS 727H +16 FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2. REPAIR ACCOMPLISH ON NON ROUTINE D457396SDR SWAA2021032252924Angle · corrodedAFT CARGO STA 727H + 20 RBL 23 TRANSITION ANGLE HAS LIGHT CORROSION MARKED / REMOVED CORROSION AT AFT CARGO R/H TRANSITION ANGLE BS 727H +20 FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2. REPAIR ACCOMPLISH ON NON ROUTINE D457396SDR SWAA2021032252925Angle · corrodedAFT CARGO STA 727I RBL 23 TRANSITION ANGLE HAS LIGHT CORROSION AROUND FASTENER MARKED / REMOVED CORROSION AFT CARGO R/H TRANSITION ANGLE BS 727I FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REPAIR ACCOMPLISH ON NON ROUTINE D457396SDR SWAA2021032252926Angle · corrodedAFT CARGO STA 727I +18 RBL 23 TRANSITION ANGLE HAS CORROSION MARKED / REMOVED CORROSION AFT CARGO R/H TRANSITION ANGLE BS 727 I +8 FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2 REPAIR ACCOMPLISH ON NON ROUTINE D457396SDR SWAA2021032252927Angle · corrodedAFT CARGO STA 727I +16 RBL 23 TRANSITION ANGLE HAS CORROSION / REMOVED CORROSION R/H TRANSITION ANGLE AFT CARGO BS 727I +16FOUND TO BE OUT OF LIMIT IAW 53-00-53-1A-2 REPAIR ACCOMPLISH ON NON ROUTINE D457396SDR SWAA2021032252928Angle · corrodedAFT CARGO STA 727I +18 RBL 23 TRANSITION ANGLE HAS CORROSION MAKRED. / REMOVED CORROSION R/H TRANSITION ANGLE AFT CARGO BS 727-I+18 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 REPAIR ACCOMPLISH ON NON ROUTINE D457396SDR SWAA2021032252929Angle · corrodedAFT CARGO STA 727J THRU 747 RBL 23 TRANSITION ANGLE HAS CORROSION MARKED / REMOVED CORROSION R/H TRANSITION ANGLE AFT CARGO BS 727 -747 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 . REPAIR ACCOMPLISH NON ROUTINE D457396SDR SWAA2021032252932Angle · corrodedAFT CARGO STA 747 THRU STA 767 RBL 23 TRANSITION ANGLE HAS CORROSION MARKED / REMOVED CORROSION AFT CARGO R/H TRANSITION ANGLE BS 747-767 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 ; REPAIR ACCOMPLISH ON NON ROUTINE D 457396SDR SWAA2021032252933Angle · corrodedAFT CARGO STA 767+50RBL 23 TRANSITION ANGLE HAS CORROSION MARKED / REMOVED AND REPLACED SECTION OF R/H TRANSITION ANGLE AT AFT CARGO BS 767-787 PER SRM 51-40-02SEE SA-M 326: A1303179SDR SWAA2021032252934Angle · corrodedAFT CARGO STA 767 +11 RBL 23 TRANSITION ANGLE HAS CORROSION MARKED / REMOVED AND REPLACD SECTION OF TRANSITION ANGLE AT AFT CARGO BS 767-787 PER SRM 51-40-02SDR SWAA2021032252947Angle · corrodedR/H T/A HAS CORROSION AROUND FASTENER HOLES BETWEEN STA 500E AND 500F / REMOVED FABRICATED AND REPLACED RIGHT TRANSITIION ANGL FROM 500A TO 500I PER SRM 53-00-53-2R-5; EA# 21-153-00535; SRM 51-40-02. ( P/N 143A7501-188) SEE SA-M 326: A1303187SDR SWAA2021031753667Gusset · crackedFORWARD CARGO BAY GUSSET IS CRACKED AT BS 540 S-19R WL 190 / REMOVED AND REPLACED FCB GUSSET AT BS 540 S-19L WL 190 I.A.W SRM. 51-40-02-0G-0 AND BOEING DWG # 143A7902SDR SWAA2021031753668Gusset · crackedFORWARD CARGO BAY GUSSET IS CRACKED AT BS540 S-19L WL 190 / REMOVED AND REPLACED FWD CARGO BAY GUSSET AT BS 540 STR. 19L. WL. 190. I.A.W SRM 51-40-02-0G-0 AND DRAWING # 143A7902. GUSSET WAS EVALUATED AND FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE LIMSDR SWAA2021031654630Floor Support · crackedFLOOR PANEL SUPPORT IS CRACKED AT BS540 LBL23; WL208 / REMOVED FLOOR PANEL SUPPORT FROM BS540; FROM BL0- LBL23 IAW B737-700 SRM 51-40-02-OG-0. LOCATED AND DRILLED PER B737-700 SRM 51-40-05-OG-0 AND BOEING DWG. #143A0060; OK TO INSTALL NEW FLOOR PANEL SUPPORT. SDR IPXA2021031166735Support · crackedINSPECTION TYPE:CUPON REMOVAL OF PANEL 343AT FOUND SUPPORT P/N A5517198520300 CRACKED IN HALFREMOVED AND REPLACED PLATE IAW SRM 51-40-21SDR IPXA2021030466391Stiffener · crackedINSPECTION TYPE:3CRH MLG W/W 3RD VERTICAL STIFFNER IS CRACKED AT LWR ENF ON OB AFT WEBREMOVED AND REPLACEDSDR A6WA202103087683Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FS424.00+2.5, LBL 36. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION COMMON TO PRESSURE FLOOR ANGLE AT FS 424.00+2.5, LBL 36 HFEC INSPECTION PERFORMED WITH NO INDICATION. EVALUATION OF BLEND AREA FOUND TO BSDR A6WA202103087697Floor Support · corrodedCORROSION COMMON TO PRESSURE FLOOR SILL AT FS 529.00+9.5 TO FS529.00+11, LBL 42 ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION ON PRESSURE FLOOR ANGLE FS529.00+9.5 TO FS529.00+11, LBL 42, PERFORMED HFEC INSPECTION WITH NO INDICATIONS, PERFORMED UT THSDR A6WA202103087689Floor Support · corrodedCORROSION COMMON TO PRESSURE FLOOR PANEL SILL AT FS473.15+5, LBL 42 ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FROM PRESSURE FLOOR PANEL SILL AT FS473.15+5, LBL 42. HFEC INSPECTION PERFORMED WITH NO INDICATIONS NOTED. EVALUATED BLEND AREA, REMAINSDR A6WA202103087692Floor Support · corrodedCORROSION COMMON TO PRESSURE FLOOR SILL AT NUTPLATE FS 513.00+9, RBL 42 ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION ON PRESSURE FLOOR SILL FS 513.00+9, RBL 42, PERFORMED HFEC INSPECTION WITH NO INDICATIONS, PERFORMED UT THICKNESS CHECK, REMAINING MSDR DALA2021030401257Floor Support · corrodedSHIP 3253 CORROSION FLOOR BEAM +Y1227 AND BETWEEN FR66 TO FR68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (1745065)SDR DALA2021030401248Sidewall Panel · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON SIDE PANEL UPPER AND LOWER SURFACE LH FROM STA 1480 TO STA 1640 AT AFT CARGO COMPARTMENT. SIDE PANEL LH FROM STA 1530 TO STA 1640 WAS REPAIRED PER SRM AND SIDE PANEL LH FROM STA 1480 TO STA 1530 SDR DALA2021030401247Sidewall Panel · corrodedDURING INSPECTION FOUND CORROSION LEVEL 2 ON SIDE PANEL UPPER AND LOWER SURFACE LH FROM STA 1480 TO STA 1640 AT AFT CARGO COMPARTMENT. SIDE PANEL REPAIRED PER SRM. (LP 1744552)SDR AALA202103309015Angle · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND CORROSION ON RIGHT TRANSITION ANGLE IN AFT CARGO AT STA 727D TO 767 AND RBL25. REMOVED AND REPLACED TRANSITION ANGLE REF AARD 51-00-05.SDR IPXA2021032767344Angle · crackedINSPECTION TYPE:3CMAIN CABIN LONGERON 15L TEE ANGLE IS CRACKED BETWEEN STA 1321 AND STA 1341.REMOVED AND REPLACED CRACKED MAIN CABIN LONGERON 15L TEE ANGLE BETWEEN STA 1321 AND 1341 IAW SRM 51-33-01 & 51-35-01. (MINOR)SDR IPXA2021032767342Angle · crackedINSPECTION TYPE:3CMAIN CABIN LONGERON 15R TEE ANGLE IS CRACKED BETWEEN STA 1321 AND STA 1341.REMOVED AND REPLACED CRACKED MAIN CABIN LONGERON 15R TEE ANGLE BETWEEN STA 1321 AND STA 1341 IAW SRM 51-33-01. (MINOR)SDR JJBA20210302032Floor Support · corrodedSERVICE DOOR FLOOR HAS SIGNS OF CORROSION. UPON REMOVED CORROSION AND EVALUATED FLOOR SILL SERVICE DOOR, FOUND TO BE OUT OF LIMITS. FLOOR SILL SERVICE DOOR WERE REMOVED AND INSTALLED. NEW FLOOR SILL SERVICE DOOR.SDR AALA202103249013Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFTHAND TRANSITION PANEL STATION 787, AFT CARGO. REPLACED ANGLE PER AARD 51-00-05.SDR SWAA2021032355729Scuff Plate · crackedFWD CARGO AFT CORNER SCUFF PLATE IS CRACKED / REMOVED AND REPLACED FCB AFT CORNER SCUFF PLATE IAW AMM 53-11-02-420-801SDR SWAA2021032353040Shield · corrodedCORROSION FWD CGO BAY; AFT R/H FLOOR TO SIDEWALL SHIELD; CORRODED AT MULTIPLE MARKED FASTENER HOLES; BS 492 -BS 500A; RBL 24; WL 156. / REMOVED AND REPLACED FCB; AFT R/H FLOOR TO SIDEWALL SHIELD AT BS 492 - BS 500A RBL 24; WL 156 IAW SRM 51-40-02 AND DWG - 143SDR SWAA2021032353041Support · corrodedCORROSION FWD CGO BAY; AFT R/H FLOOR TO SIDEWALL SUPPORT; CORRODED AT MULTIPLE MARKED FASTENER HOLES; BS 500A - BS 500D; RBL 24; WL 156. / REMOVED AND REPLACED FWD CARGO BAY; AFT R/H FLOOR TO SIDEWALL SUPPORT AT BS 500A - 500D; RBL 24; WL 156 IAW SRM 51-40-02-SDR SWAA2021032353042Support Angle · corrodedCORROSION FWD CGO BAY; AFT BULKHEAD SUPPORT; CORRODED AT MARKED FASTENER HOLE; BS 500D; RBL 25; WL 156. / REMOVED AND REPLACED AFT BULKHEAD SUPPORT ANGLE AT B/S 500D; RBL 25; WL 156 LOT# 7530202 IAW SRM 51-40-02 SRM 51-10-02 PARAGRAPH 9 AND DWG 143A7902 REV: 5SDR SWAA2021032353043Support · corrodedCORROSION FWD CGO BAY; AFT BULKHEAD SUPPORT; CORRODED AT MARKED FASTENER HOLE; BS 500D; LBL 26; WL 156. / REMOVED AND REPLACED FCB AFT BULKHEAD SUPPORT BS 500D; LBL 26; WL 156 IAW SRM 51-40-02 AND DWG 143A9481; DWG 147A2150SDR SWAA2021032353034Support · corroded***CORROSION*** FWD CGO BAY; L/H FLOOR TO SIDEWALL SUPPORT HAS CORROSION AT MULTIPLE LOCATIONS (MARKED) BS 400 - BS 500D; LBL 25; WL 156. / REMOVED AND INSTALLED NEW AT FCB L/H FLOOR TO SIDEWALL SUPPORT BS400-BS500D LBL25 FABRICATED FLOOR TO SIDEWALL. SUPPORT SDR SWAA2021032355725Angle · chafedLT SIDE FUSELAGE FIN TO BODY INTERFACE CLOSURE ANGLE BS 1016 - BS 1132 HAS CHAFFING DAMAGE / EVALUATED CHAFFING DAMAGE ON L/H CLOSURE ANGLE BS 1016 - BS 1132. FOUND TO BE OUT OF LIMITS DUE TO NO SRM ALLOWABLE DAMAGE. PART WILL BE REPAIRED BY REPLACEMENT IAW SRSDR SWAA2021032355726Angle · chafedLT SIDE FUSELAGE FIN TO BODY INTERFACE CLOSURE ANGLE FORWARD OF BS 1016 HAS CHAFFING DAMAGE / EVALUATED CHAFFING DAMAGE ON LH CLOSURE ANGLE FWD OF BS 1016 FOUND TO BE OUT OF LIMITS DUE TO NO SRM ALLOWABLE DAMAGE. THE STRUCTURAL ITEM WILL BE REPAIRED BY REPLACESDR SWAA2021032355727Angle · chafedRT SIDE FUSELAGE FIN TO BODY INTERFACE CLOSURE ANGLE FORWARD OF BS 1016 HAS CHAFFING DAMAGE / EVALUATED CHAFFING DAMAGE ON R/H CLOSE ANGLE FWD OF BS 1016 FOUND TO BE OUT OF LIMITS DUE TO NO SRM ALLOWABLE DAMAGE. PART WILL BE PREPAIRED BY REPLACEMENT IAW SRM 51SDR SWAA2021032355728Angle · chafedRT SIDE FUSELAGE FIN TO BODY INTERFACE CLOSURE ANGLE BS 1016 - BS 1132 HAS CHAFFING DAMAGE / REMOVED AND REPLACED CLOSURE ANGLE R/H SIDE FUSELAGE FIN TO BODY INTERFACE; AT BS 1016 - BS 1132 IAW SRM 51-40-02-0G-0 DWG 148A8300; 148A3590SDR REXA2021030200126Floor Support · corrodedFLOOR SILL PLATE AT RBL 42 IS CORRODED BETWEEN FS 310.00 AND FS 319.70 - REMOVED, LOCATED, DRILLED AND INSTALLED FLOOR SILL AT RBL 42 FS 280 - FS 319.70 IAW CRJ 700 SRM 51-42-06-001-001-A01, 51-40-11-001-001-A01,51-42-21-001-001-A01 AND 51-42-13-001-001-A01. SDR HALA2021030400034Support · crackedSHIP 378 AFT CABIN RH Z-SECTION FROM FRAME 77-FRAME 79 WITH A CRACK IN 1 OFF FASTENER HOLE THROUGH TO THE EDGE. CORRECTIVE ACTION: REMOVED AND REPLACED I.A.W A330 SRM 51-42-11. (1745366)SDR DALA2021030401236Sidewall Panel · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON LH SIDE PANEL BTW STA 1410 TO 1530. SIDE PANEL WAS REPLACED. (LP 1744240)SDR DALA2021030401223Floor Support · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON 2 FLOOR STRINGERS RBL 2.90, 7.55,10.45 AND LBL 2.90, 7.55,10.45 BTW STA 1500 TO STA 1520 AT AFT CARGO COMPARTMENT. STRINGERS RBL 2.90, AND LBL 2.90, BTW STA 1500 TO STA 1520 AT AFT CARGO COMPARTMENT WERESDR JR2R03022021030Angle · corrodedFLOOR BEAM AT FR87 RH O/B FLOOR PANEL CLIP CORRODEDSDR SWIA202158304Reinforcement · damagedCOMPLY WITH REO 601R-53-41-1116 REPAIR & REINFORCEMENT FOR FS 559.00 LWR CAP ANGLES BL 9.00 & 18.00 LHS & RHS (C-CHECK RO 5/20/2021) COMPLIED WITH REO 601R-53-41-1116 REV. C DATED 2017/03/09. REPAIR & REINFORCEMENT FOR FS 559.00 LWR CAP ANGLES BL 9.00 &SDR IPXA2021033167574Support · corrodedINSPECTION TYPE:A300AFT CARGO CEILING LINER SUPPORT AR FR 58 CORRODEDREMOVED,FABRICATED 3EA AND INSTALLED NEW CEILING LINER SUPPORT PER A300 SRM 51-40-21.SDR IPXA2021040167624Floor Support · corrodedINSPECTION TYPE:3CMAIN CABIN FLOOR SUPPORT AT STA 1976 AND RBL 20 HAS CORROSION.REMOVED AND REPLACED CORRODED MAIN CABIN FLOOR SUPPORT BETWEEN STA 1887 - STA 2007 AT RBL 25.550 IAW VT-SAA EA 011-5310-01-A8973 REV. IR AND UPS EO MD11-5310-79767-A. (MINOR)SDR IPXA2021040167623Floor Support · corrodedINSPECTION TYPE:3CMAIN CABIN FLOOR SUPPORT AT STA 1990 AND RBL 55 HAS CORROSION.REMOVED AND REPLACED CORRODED MAIN CABIN FLOOR SUPPORT BETWEEN STA 1887 - STA 2007 AT RBL 55.650 IAW VT-SAA EA 011-5310-01-A8973 REV. IR AND UPS EO MD11-5310-79767-A. (MINOR)
Back to JASC 5320