What was found
DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON 2 FLOOR STRINGERS RBL 2.90, 7.55,10.45 AND LBL 2.90, 7.55,10.45 BTW STA 1500 TO STA 1520 AT AFT CARGO COMPARTMENT. STRINGERS RBL 2.90, AND LBL 2.90, BTW STA 1500 TO STA 1520 AT AFT CARGO COMPARTMENT WERE REPLACED AND STRINGER RBL 7.55,10.45 AND LBL 7.55,10.45 BWT STA 1500 TO 1520 WERE REPAIRED WERE REPAIRED PER SRM. (LP 1744061)