JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A2021021900171Shear Panel · corrodedCFIII, FLOOR STRUCTURE, CORROSION FOUND ON RT SHEAR PANEL BTWN FR 87-88. CRIII, FLOOR STRUCTURE, RT SHEAR PANEL BTWN FR 87-88 REPLACED IAW ERJ-175 SRM 51-42-03.SDR R61A2021021900167Shear Panel · corrodedCFIII, FLOOR STRUCTURE, CORROSION FOUND ON MID SHEAR PANEL BTWN FR87-88. CFIII, FLOOR STRUCTURE ON MID SHEAR PANEL BTWN FR 87-88 REPLACED IAW ERJ - 175 SRM 51-42-01.SDR R61A2021021900170Floor Support · corrodedCFIII FLOOR STRUCTURE, CORROSION FOUND ON RT SUPPORT BTWN FR 88-90. REPLACED IAW EMB SRM 51-42-01 & 51-43-01.SDR R61A2021021900165Doubler · corrodedCFIII FLOOR STRUCTURE, CORROSION FOUND ON DOUBLER FLOOR AT FR 84, OUTBD OF RT INBD SEAT TRACK. REPLACED FLOOR DOUBLER AT FR 84 JUST OTBD OF RT INBD SEAT TRACK WITH NEW PN 170-92856-001 IAW SRM 51-43-04.SDR SIMA20210204003Door Sill · corrodedCARGO DOOR LOWER SILL IS CORRODED BETWEEN FR 65-66 CORROSION LEVEL 2. C/A-R & R CARGO DOOR LOWER SILL IAW EMB 145 SRM 51-40-02.SDR R61A2021021600158Floor Support · corrodedCFIII, FLOOR STRUCTURE, CORROSION FOUND ON LH BEAM BTWN FR 86-89. CFIII, FLOOR STRUCTURE, CORRODED LH BEAM BTWN 86-89, REMOVED AND REPLACED IAW EMB 170/175 SRM 51-41-01 AND 51-43-01. LVL. 2SDR VNAA202102081111Striker · dentedDURING SCHEDULED MAINTENANCE, THE MAINTENANCE TEAM IDENTIFIED THAT THE SH670-31912-5 LOWER SEAL STRIKER PLATE WAS REPAIRED VIA REO 670-53-22-085 AND A TEMPORARY FASTENER (CR3212-4 OR CR3222-4 OR CR3522-4) INSTALLED. MAINTENANCE REQUESTS A PERMANENT REPAIR (MS2SDR FDEA202102040286Angle · crackedMAIN EQUIPMENT CENTER, LEFT TUNNEL STATION 246 LBL 50 UPPER FLOOR ANGLE CRACKED. REMOVED AND REPLACED FLOOR ANGLE CLIP 141T5146-16 IAW BAC DWG 141T5600 REV.B.SDR SWAA2021031546971Angle · corrodedCORROSION ON CLIP AT AFT CARGO BAY BS727D RBL7 WL150. / REMOVED AND REPLAED CLIP AT AFT CARGO BAY B/S 727D RBL7 WL150 P/N 146A1320-81 IAW SRM 51-40-02 SRM 51-10-02 PARAGRAPH 9 AND DWG 146A7810 REV:A 59900U 20FEB21SDR SWAA2021031546976Splice · corrodedCORROSION ON FLOOR SUPPORT SPLICE AT AFT CARGO BAY BS887 RBL20 TO LBL8 WL168. / REMOVED AND REPLACED FLOOR SUPPORT SPLICE AT ACB BS887 RBL20 TO LBL8 WL168 IAW SRM 51-40-02 AND DWG# 146A9401. NEW PART RECIEVED ON PO# 813007. 59118U 17FEB21SDR SWAA2021031546982Bracket · corrodedCORROSION ON SUPPORT AT AFT CARGO BAY BS949 BL0 WL178. / REMOVED AND REPLACED SUPPORT BRACKET; AT AFT CARGO BAY BS949 BL0 WL178 PER SRM 51-40-02 AND DWG# 147A1047 REV: -.SDR SWAA2021031546986Angle · corrodedCORROSION ON WEB TO SHIELD ATTACH ANGLE AT AFT CARGO BAY BS767 - BS787 RBL21 WL156. / NO ALLOWABLE LIMITS FOUND IN SRM FOR SHEILD ATTACH ANGLE PART TO BE REPAIRED BY REPLACEMENT. REMOVED SHEILD ATTACH ANGLE PER SRM 51-40-02. RECEIVED REPLACEMENT ANGLE LOCATED SDR SWAA2021031546988Angle · corrodedCORROSION ON CLIP AT AFT CARGO BAY BS 727E, RBL 5, WL 150. REMOVED AND REPLACED CLIP AT AFT CARGO BAY BS 727E RBL5 WL150 PN 146A132082 IAW SRM 514002; SRM 511002 PARAGRAPH 9 AND DWG 146A7810 REV:A 59900U 20FEB21.SDR SWAA2021031546993Angle · crackedCRACKED SUPPORT ANGLE AT AFT CARGO BAY BEHIND WATER SERVICE PANEL BS914 RBL11 WL171. / REMOVED AND REPLACED ACB WATER SERVICE PANEL SUPPORT ANGLE - B/S 914; RBL11 WL171 IAW SRM 51-40-02-0G-0; DWG# 147A7221.SDR SWAA2021031546992Bracket · crackedCRACKED ATTACH ANGLE AT AFT CARGO BAY BS807 RBL20 WL158. / EVALUATED REMOVED AND REPLACE WITH NEW BRACKET IAW DWG 146A8340; SRM 51-40-02; DWG 146A8120; SRM 51-40-05; SOPM 20-30-03SDR SWAA2021031546994Angle · crackedCRACKED SUPPORT ANGLE AT AFT CARGO BAY BEHIND WATER SERVICE PANEL BS918 RBL11 WL171. / REMOVED AND REPLACED ACB WATER SERVICE PANEL SUPPORT ANGLE - B/S 918; WL171 IAW SRM 51-40-02-0G-0; DWG# 147A7221SDR SWAA2021031546997Angle · corrodedCORROSION AT APU COMPARTMENT ON ANGLE BS1125; RBL15; 11' WL 239 BELOW LOWER HORIZONTAL DECK. MARKED / CORROSION ON APU COMPARTMENT ANGLE AT BS 1125 RBL15 WL239 FOUND TO BE OUT OF LIMITS PER SRM 53-80-13-1A-2. REMOVED AND REPLACED ANGLE IAW BOEING DWG 148A8650 SDR SWAA2021031146983Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727 - BS787 LBL21 WL156. / REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT AT ACB BS727-787 LBL21 WL156 I.A.W. SRM 51-40-02 AND DWG 146A7500 REV:-SDR SWAA2021031146984Support · corroded***CORROSION*** ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727 - BS767 RBL21 WL156. / REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT ACB BS727-767 IN AREA OF L=6' X W=.8' X D=.008' REMAINING THICKNESS .032' FROM ORIGINAL THICKNESS .060' FOUND TO BE OUTSDR SWAA2021031146980Intercostal · corroded***CORROSION*** ON INTERCOSTAL AT AFT CARGO BAY BS787 - BS807 RBL6 WL156. / REMOVED CORRODED INTERCOSTAL AND REPLACED WITH NEW IAW SRM 53-60-15-1A-1; SRM 53-60-15-1A-1; SRM 51-40-05. DWG 146A8130 REV B 92954U 2/18/21SDR SWIA202156823Angle · crackedL/H LBL 9 ANGLE FS 265 TO 280 IS CRACK (C-CHECK) RO 3/10/2021 REMOVED AND REPLACED L/H LBL 9 J ANGLE AT FS 265 TO 280 IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01SDR SWIA202156822Angle · crackedR/H RBL 9 ANGLE FS 265 TO 280 IS CRACK (C-CHECK) RO 3/10/2021 REMOVED AND REPLACED R/H RBL 9 J ANGLE AT FS 265 TO 280 IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01SDR SWAA2021030853647Channel · corrodedCORROSION ON RAIL AROUND FASTENER HOLE BS727B+3 LBL3 WL156. / PERFORM CUT-OUT FROM BS727+7' TO BS 727B+10' LBL3 WL156 I.A.W SRM 53-00-53-2R-2 STEP 2.F. LOCATED; DRILLED AND COUNTERSANK NEW REPAIRABLE BEAM AND CHANNEL SPLICE I.A.W SRM 53-00-53-2R-2; SRM 51-40-0SDR SWAA2021030846991Channel · chafedCHAFING DAMAGE ON RAIL AT AFT CARGO BAY BS751 LBL12 WL156. / PERFORMED CUTOUT THE DAMAGE SECTION AT BS 751 LBL 12 WL 156 I.A.W SRM 53-00-53-2R-2 STEP 2.F. LOCATED AND DRILLED NEW CHANNEL SPLICE AND NEW CHANNEL FILLER IAW SRM 51-40-05 AND SRM 53-00-53-2R-2. APPSDR SWAA2021030846998Angle · corrodedCORROSION AT APU COMPARTMENT ON ANGLE BS1156; BL0; 31' WL 236 BELOW LOWER HORIZONTAL DECK. MARKED / REPAIRED APU COMPARTMENT ANGLE B.S1156 BL0 3' BELOW LWR HORIZONTAL DECK IAW EA 21-153-00464 REV IR AND ATS ER 21-01243 REV IRSDR AALA202103089009Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: FOUND 0.905 INCH CRACK ON SHEAR PLATE AT FR69 AND STR 23R IN AFT GALLEY AREA. REPLACED SHEAR PLATE IAW A 321 SRM 51-42-11-801, SRM 51-72-11-911-001 AND DRAWING 5347180.SDR AALA202103059096Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE AT FR 69 AND S23L. REPLACED SHEAR PLATE PER SRM 51-72-11SDR SWAA2021030447346Scuff Plate · crackedAFT CARGO BAY AFT CORNER SCUFF PLATE IS CRACKED. REJECTION: REPAIR INCOMPLETE; SRM 53-60-15-2R-1 STEPS 4B(6)(7). TREAT AND PRIME. / REPAIRED PER:SRM 53-60-15-2R1 REAPPLIED PROTICTIVE FINISH PER: SRM 53-60-15-2R1SDR AALA202102261931Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT LEFT PASSENGER / CREW DOOR CUT OUT LOWER SILL CENTER SHAPE FITTING AT FR 66 AND S23L. REPLACED CENTER SHAPE FITTING PER SRM 51-72-11.SDR REXA2021022300073Intercostal · corrodedAVI DOOR FWD INTERCOSTAL BETWEEN FS 349 TO FS 364 & STGR 27 TO STGR 26R IS CORRODED ON THE BOTTOM FLANGE. REMOVED AND REPLACED INTERCOSTALS IAW CRJ 900 SRM 51-42-06-001-001-A01 & 51-42-21-001-001-A01.SDR R61A2021021900164Doubler · corrodedFWD FUSELAGE, FLOOR STRUCTURE, CORROSION FOUND AT RT DOUBLER SILL BTWN FR 12-14. FWD FUSELAGE, FLOOR STRUCTURE, CORRODED RT DOUBLER SILL BTWN FR 12-14, REMOVED AND REPLACED IAW EMBRAER 170/175 SRM 51-41-02 AND 51-43-02.SDR IPXA2021021665720Stiffener · crackedINSPECTION TYPE:C13CRACK ON CENTER WING TANK STIFFENER(P/N:111T2005-7) ON STA 785.9,LBL 11.REPAIR I.A.W 767-300F SRM 57-10-10-2R-2 REPAIR 2 REV.79.01 AND UPS EO B767-5740-58151-CSDR IPXA2021021665719Stiffener · crackedINSPECTION TYPE:C13CRACK ON CENTER WING TANK STIFFENER(P/N:111T2005-8) ON STA 785.9,RBL 11.REPAIR I.A.W 767-300F SRM 57-10-10-2R-2 REPAIR 2 REV.79.01 AND UPS EO B767-5740-58151-CSDR FDEA202102030277Support · crackedAFT PIT DOOR CUT-OUT FWD CEILING SUPPORT ANGLE CRACKED REMOVED AND REPLACED CEILING SUPPORT ANGLE IAW BAC DWG 146T8501 REV: BSDR A6WA202102047578Floor Support · corrodedFLOOR SUPPORT L/H AT FS559.O CORRODED BEYOND LIMITS ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED AND REPLACED FLOOR SUPPORT L/H AT FS559.OSDR A6WA202102047577Floor Support · corrodedFS559.00 FLOOR SUPPORT CORRODED BEYOND LIMITS ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED AND REPLACED FLOOR SUPPORT AF FS559.00SDR DALA2021020400671Seat Track · corrodedSHIP 3252 CORROSION SEAT TRACK +Y765 AND FR20 AT FWD GALLEY AREA. CORRECTIVE ACTION REPLACED SEAT TRACK PER A320 SRM 51-72-11.SDR DALA2021020400669Web · corrodedSHIP 3252 CORROSION WEB LOCATED -Y1732 AND FR20 AT FWD GALLEY AREA. CORRECTIVE ACTION REPLACED WEB PER A320 SRM 51-72-11.SDR 6PMR20210203001Profile · crackedPEMCO N/R 10449.0518 DISCREPANCY: POSSIBLE CRACKS ON LT FWD OVER-WING EXIT DOOR IN AREA OF LT LOAD TRANSMITTING PROFILE. CORRECTIVE ACTION: REMOVED AND REPLACED FRAME SEGMENT, IAW A320 SRM 51-72-11-911-001 SH 1-3.SDR SWIA202158458Support Angle · corrodedSERVICE DOOR SILL PROTECTOR PLATE COVER SUPPORT ATTACH ANGLES, TOTAL 4 ANGLES BETWEEN FS310.00 THRU FS349.00 HAVE SURFACE CORROSION. (C-CHECK RO 5/23/2021) REPLACED ANGLES IAW CRJ700 SRM 51-42-06.SDR SWIA202157126Intercostal · crackedAPU INLET DOOR ACTUATOR INTERCOSTAL AT F.S. 654.50 STGR 4L IS CRACKED AT BOTTOM FWD CORNER. (C-CHECK RO 4/1/2021) REPAIRED DAMAGE ON THE APU INLET DOOR ACTUATOR INTERCOSTAL AT F.S. 654.50 STGR 4L IAW MHIRJ REO 601R-53-62-300 REV -- DATED 2021-02-23. REFESDR SWAA2021031550855Bracket · crackedRIGHT ECS BAY HAS CRACKED DUCT SUPPORT BRACKET (212A1116) ACCESS PANEL 192CR BS540+6 RBL8. MARKED / REMOVED CRACKED DUCT SUPPORT BRACKETS AND INSTALLED NEW BRACKET ALL IAW SRM 51-40-02-0G-0SDR SWIA202156900Threshold · corrodedSERVICE DOOR THRESHOLD IS CORRODED. (C-CHECK) RO 3/10/2021 REMOVED CORROSION FROM SERVICE DOOR THRESHOLD REF CRJ-200-SRM 51-21-06. BLENDED AREA FOUND TO BE OUT OF LIMITS REF DRAWING 601R38695 REV G REPLACED SERVICE DOOR THRESHOLD PART # 601R38957-31 REF CSDR AALA202103055507Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR AALA202103051453Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR AALA202103021922Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT LEFT HAND PASSENGER / CREW DOOR CUT OUT LOWER SILL CENTER SHAPE FITTING AT FR 68 AND S23L. REPLACED SILL CENTER SHAPE FITTING PER SRM 51-72-11.SDR AALA202102264512Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND AFT PASSENGER / CREW DOOR CUT OUT LOWER SILL SHAPE FITTING AT FR 68 AND S23R. REPLACED SILL SHAPE FITTING PER SRM 51-72-11.SDR SWAA2021022546590Intercostal · corrodedRH INTERCOSTAL UNDER TRANSITION ANGLE AT STA 747 TO STA 767 CORRODED OUT OF LIMITS. / REMOVED AND REPLACED AFT CARGO RT INTERCOSTAL BETWEEN STA 747 TO STA 767 IAW SRM 51-40-02SDR R61A2021021600159Bracket · corrodedCORROSION FOUND ON BRACKET AT WASTE WATER ACCESS DOOR BTWN FR 88-89. WASTE WATER ACCESS DOOR BRACKET BTWN FR 88-89 FOUND CORRODED, HAS BEEN REMOVED & REPLACED IAW E175 SRM 51-41-02 & 170-86668-403 LVL. 2SDR FDEA202102020292Floor Support · corrodedCTR CARGO - FLOOR SUPPORT CHANNEL CORRODED AT STA 1781 (MRKD). REMOVED AND REPLACED CORRODED FLOOR SUPPORT AFA8359-19 PER SRM 51-31-01-0G.
Back to JASC 5320