What was found
FWD FUSELAGE, FLOOR STRUCTURE, CORROSION FOUND AT RT DOUBLER SILL BTWN FR 12-14. FWD FUSELAGE, FLOOR STRUCTURE, CORRODED RT DOUBLER SILL BTWN FR 12-14, REMOVED AND REPLACED IAW EMBRAER 170/175 SRM 51-41-02 AND 51-43-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.